An aptamer-based paper microfluidic device for the colorimetric determination of cocaine

被引:35
|
作者
Wang, Ling [1 ]
Musile, Giacomo [2 ]
McCord, Bruce R. [1 ]
机构
[1] Florida Int Univ, Dept Chem & Biochem, CP 304,11200 SW 8th St, Miami, FL 33199 USA
[2] Univ Verona, Dept Diagnost & Publ Hlth, Unit Forens Med, Verona, Italy
关键词
Aptamer; Gold nanoparticle; Paper microfluidic device; Seized cocaine; GOLD NANOPARTICLES; OPTICAL-PROPERTIES; SENSOR;
D O I
10.1002/elps.201700254
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A method utilizing paper microfluidics coupled with gold nanoparticles and two anticocaine aptamers has been developed to detect seized cocaine samples. The ready-to-use format involves the use of a paper strip that produces a color change resulting from the salt-induced aggregation of gold nanoparticles producing a visible color change indicating the presence of the drug. This format is specific for the detection of cocaine. The visual LOD for the method was 2.5g and the camera based LOD was 2.36g. The operation of the device is easy and rapid, and does not require extensive training or instrumentation. All of the materials utilized in the device are safe and environmental friendly. This device should prove a useful tool for the screening of forensic samples.
引用
收藏
页码:470 / 475
页数:6
相关论文
共 50 条
  • [1] Aptamer-based fluorometric determination of norovirus using a paper-based microfluidic device
    Xuan Weng
    Suresh Neethirajan
    [J]. Microchimica Acta, 2017, 184 : 4545 - 4552
  • [2] Aptamer-based fluorometric determination of norovirus using a paper-based microfluidic device
    Weng, Xuan
    Neethirajan, Suresh
    [J]. MICROCHIMICA ACTA, 2017, 184 (11) : 4545 - 4552
  • [3] Aptamer-based colorimetric probe for cocaine
    Stojanovic, MN
    Landry, DW
    [J]. JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2002, 124 (33) : 9678 - 9679
  • [4] Aptamer-based colorimetric determination of Pb2+ using a paper-based microfluidic platform
    Fakhri, Neda
    Hosseini, Morteza
    Tavakoli, Omid
    [J]. ANALYTICAL METHODS, 2018, 10 (36) : 4438 - 4444
  • [5] Electrogenerated chemiluminescence aptamer-based biosensor for the determination of cocaine
    Li, Yan
    Qi, Honglan
    Peng, Yage
    Yang, Jia
    Zhang, Chengxiao
    [J]. ELECTROCHEMISTRY COMMUNICATIONS, 2007, 9 (10) : 2571 - 2575
  • [6] An aptamer-based microfluidic device for thermally controlled affinity extraction
    Nguyen, ThaiHuu
    Pei, Renjun
    Stojanovic, Milan
    Lin, Qiao
    [J]. MICROFLUIDICS AND NANOFLUIDICS, 2009, 6 (04) : 479 - 487
  • [7] An aptamer-based microfluidic device for thermally controlled affinity extraction
    ThaiHuu Nguyen
    Renjun Pei
    Milan Stojanovic
    Qiao Lin
    [J]. Microfluidics and Nanofluidics, 2009, 6
  • [8] Aptamer-Based Microfluidic Biosensors
    Lin, Qiao
    Thaihuu Nguyen
    [J]. 2009 9TH IEEE CONFERENCE ON NANOTECHNOLOGY (IEEE-NANO), 2009, : 812 - 814
  • [9] Determination of cocaine on banknotes through an aptamer-based electrochemiluminescence biosensor
    Qihong Cai
    Lifen Chen
    Fang Luo
    Bin Qiu
    Zhenyu Lin
    Guonan Chen
    [J]. Analytical and Bioanalytical Chemistry, 2011, 400 : 289 - 294
  • [10] Determination of cocaine on banknotes through an aptamer-based electrochemiluminescence biosensor
    Cai, Qihong
    Chen, Lifen
    Luo, Fang
    Qiu, Bin
    Lin, Zhenyu
    Chen, Guonan
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2011, 400 (01) : 289 - 294