Simulated Mid-ranging Control of Propofol and Remifentanil using EEG-measured Hypnotic Depth of Anesthesia

被引:0
|
作者
Soltesz, Kristian [1 ]
Dumont, Guy A.
van Heusden, Klaske
Hagglund, Tore [1 ]
Ansermino, J. Mark
机构
[1] Lund Univ, Dept Automat Control, Lund, Sweden
关键词
Medical control systems; Drug delivery; Control system synthesis; Medical simulation; CLOSED-LOOP CONTROL; BISPECTRAL INDEX; PERFORMANCE; PAIN;
D O I
暂无
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
This paper suggests an extension of an existing, clinically evaluated, closed-loop drug delivery system for hypnotic depth control using propofol. The extension introduces closed-loop administration of the analgesic drug remifentanil, thus forming a multiple input-single output (MISO) control system. Remifentanil acts and is metabolized at a significantly faster time scale than propofol. Direct control of analgesia is hindered by the current absence of a reliable real-time nociception monitor. However, several hypnotic depth monitors respond to nociception. Sudden changes in the measured hypnotic depth are frequently caused by changes in noxious stimulation. The novelty of this work lies in increasing the disturbance rejection bandwidth of the control system for hypnotic depth by directing the high frequency content of its control error to a remifentanil controller. Such a mid-ranging control system was implemented and tuned based on 23 patient models obtained from a previous clinical study and its performance is demonstrated through a simulation study.
引用
收藏
页码:356 / 361
页数:6
相关论文
共 9 条
  • [1] Bioreactor control using a probing feeding strategy and mid-ranging control
    Velut, S.
    de Mare, L.
    Hagander, P.
    [J]. CONTROL ENGINEERING PRACTICE, 2007, 15 (02) : 135 - 147
  • [2] Control of the Depth of Anesthesia Using a New Model for the Action of Propofol and Remifentanil on the BIS Level
    Silva, Jorge
    Mendonca, Teresa
    Rocha, Paula
    [J]. CONTROLO 2020, 2021, 695 : 497 - 506
  • [3] Depth of Anesthesia During Multidrug Infusion: Separating the Effects of Propofol and Remifentanil Using the Spectral Features of EEG
    Kortelainen, Jukka
    Vayrynen, Eero
    Seppanen, Tapio
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2011, 58 (05) : 1216 - 1223
  • [4] Evaluation of the aepEX™ TM monitor of hypnotic depth in pediatric patients receiving propofol-remifentanil anesthesia
    Cheung, Yuen M.
    Scoones, Gail P.
    Hoeks, Sanne E.
    Stolker, Robert J.
    Weber, Frank
    [J]. PEDIATRIC ANESTHESIA, 2013, 23 (10) : 891 - 897
  • [5] Exactly linearizing adaptive control of propofol and remifentanil using a reduced Wiener model for the depth of anesthesia
    da Silva, Margarida Martins
    Wigren, Torbjorn
    Mendonca, Teresa
    [J]. 2012 IEEE 51ST ANNUAL CONFERENCE ON DECISION AND CONTROL (CDC), 2012, : 368 - 373
  • [6] Monitoring of anesthetic depth and EEG band power using phase lag entropy during propofol anesthesia
    Shin, Hye Won
    Kim, Hyun Jung
    Jang, Yoo Kyung
    You, Hae Sun
    Huh, Hyub
    Choi, Yoon Ji
    Choi, Seung Uk
    Hong, Ji Su
    [J]. BMC ANESTHESIOLOGY, 2020, 20 (01)
  • [7] Monitoring of anesthetic depth and EEG band power using phase lag entropy during propofol anesthesia
    Hye Won Shin
    Hyun Jung Kim
    Yoo Kyung Jang
    Hae Sun You
    Hyub Huh
    Yoon Ji Choi
    Seung Uk Choi
    Ji Su Hong
    [J]. BMC Anesthesiology, 20
  • [8] Burst suppression ratio may be a reliable parameter in assessment of the depth of anesthesia with propofol using processed-EEG monitor
    Shibue, C
    Shimoji, K
    [J]. ANESTHESIOLOGY, 2000, 93 (3A) : U146 - U146
  • [9] The influence of moderate or deep neuromuscular block status on anesthetic depth monitoring system during total intravenous anesthesia using propofol and remifentanil: A randomized trial
    Na, Hyo-Seok
    Lim, Dae-Jin
    Koo, Bon-Wook
    Oh, Ah-Young
    Lee, Pyung-Bok
    [J]. SCIENCE PROGRESS, 2021, 104 (02)