THE IMPACT OF WORKFLOW AND VOLUMETRIC FEEDBACK ON FRAMELESS IMAGE-GUIDED NEUROSURGERY

被引:10
|
作者
Woerdeman, Peter A. [1 ]
Willems, Peter W. A. [1 ]
Noordmans, Herke J. [2 ]
Tulleken, Cornelis A. F. [1 ]
Van der Sprenkel, Jan W. B. [1 ]
机构
[1] Univ Med Ctr Utrecht, Dept Neurosurg, Rudolf Magnus Inst Neurosci, NL-3584 CX Utrecht, Netherlands
[2] Univ Med Ctr Utrecht, Dept Med Technol & Clin Phys, NL-3584 CX Utrecht, Netherlands
关键词
Brain shift; Instrument tracking; Interface; Neuronavigation; Tumor resection; INTRAOPERATIVE 3D ULTRASOUND; BRAIN-TUMOR RESECTION; FUNCTIONAL NEURONAVIGATION; INITIAL-EXPERIENCE; MRI; SURGERY; GLIOMAS; VISUALIZATION; LOCALIZATION; TRACTOGRAPHY;
D O I
10.1227/01.NEU.0000335791.85615.38
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
OBJECTIVE: During image-guided neurosurgery, if the surgeon is not fully orientated to the surgical position, he or she will briefly shift attention toward the visualization interface of an image guidance station, receiving only momentary "point-in-space" information. The aim of this study was to develop a novel visual interface for neuronavigation during brain tumor surgery, enabling intraoperative feedback on the entire progress of surgery relative to the anatomy of the brain and its pathology, regardless of the interval at which the surgeon chooses to look. METHODS: New software written in Java (Sun Microsystems, Inc., Santa Clara, CA) was developed to visualize the Cumulative recorded instrument positions intraoperatively. This allowed surgeons to see all previous instrument positions during the elapsed surgery. This new interactive interface was then used in 17 frameless image-guided neurosurgical procedures. The purpose of the first 11 cases was to obtain clinical experience with this new interface. In these cases, workflow and volumetric feedback (WVF) were available at the surgeons' discretion (Protocol A). In the next 6 cases, WVF was provided only after a complete resection was claimed (Protocol B). RESULTS: With the novel interactive interface, dynamics of surgical resection, displacement of cortical anatomy, and digitized functional data could be visualized intraoperatively. In the first group (Protocol A), surgeons expressed the view that WVF had affected their decision making and aided resection 0 0 of I I cases). In 3 of 6 cases in the second group (Protocol B), tumor resections were extended after evaluation of WVF By digitizing the cortical surface, an impression of the cortical shift could be acquired in all 17 cases. The maximal cortical shift measured 20 mm, but it typically varied between 0 and 10 mm. CONCLUSION: Our first clinical results suggest that the embedding of WVF contributes to improvement of surgical awareness and tumor resection in image-guided neurosurgery in a swift and simple manner.
引用
收藏
页码:S170 / S176
页数:7
相关论文
共 50 条
  • [1] Sound and volumetric workflow feedback during image guided neurosurgery
    Noordmans, Herke Jan
    Woerdeman, Peter A.
    Willems, Peter W. A.
    van Rijen, Peter C.
    van der Sprenkel, Jan W. Berkelbach
    PHOTONIC THERAPEUTICS AND DIAGNOSTICS IV, 2008, 6842
  • [2] Clinical experience of image-guided neurosurgery with a frameless navigation system (StealthStation™)
    Morioka, T
    Nishio, S
    Ikezaki, K
    Natori, Y
    Inamura, T
    Muratani, H
    Muraishi, M
    Hisada, K
    Mihara, F
    Matsushima, T
    Fukui, M
    NEUROLOGICAL SURGERY, 1999, 27 (01): : 33 - 40
  • [3] Image-guided neurosurgery
    Wadley, J
    Kitchen, N
    Thomas, D
    HOSPITAL MEDICINE, 1999, 60 (01): : 34 - 38
  • [4] Image-guided neurosurgery with intraoperative MRI: Update of frameless stereotaxy and radicality control
    Wirtz, CR
    Tronnier, VM
    Bonsanto, MM
    Knauth, M
    Staubert, A
    Albert, FK
    Kunze, S
    STEREOTACTIC AND FUNCTIONAL NEUROSURGERY, 1997, 68 (1-4) : 39 - 43
  • [5] INTERACTIVE IMAGE-GUIDED NEUROSURGERY
    GALLOWAY, RL
    MACIUNAS, RJ
    EDWARDS, CA
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1992, 39 (12) : 1226 - 1231
  • [6] Fluorescence image-guided neurosurgery
    Kaneko, Sadao
    Eljamel, Muftah S.
    FUTURE ONCOLOGY, 2017, 13 (26) : 2341 - 2348
  • [7] Coregistered volumetric true 3D ultrasonography in image-guided neurosurgery
    Ji, Songbai
    Hartov, Alex
    Fontaine, Kathryn
    Borsic, Andrea
    Roberts, David
    Paulsen, Keith
    MEDICAL IMAGING 2008: VISUALIZATION, IMAGE-GUIDED PROCEDURES, AND MODELING, PTS 1 AND 2, 2008, 6918
  • [8] Application accuracy in frameless image-guided neurosurgery: a comparison study of three patient-to-image registration methods
    Woerdeman, Peter A.
    Willems, Peter W. A.
    Noordmans, Herke J.
    Tulleken, Cornelis A. F.
    Van der Sprenkel, Jan Willem Berkelbach
    JOURNAL OF NEUROSURGERY, 2007, 106 (06) : 1012 - 1016
  • [9] Novalis frameless image-guided radiosurgery and radiotherapy
    Wurm, R.
    Erbel, S.
    Gum, F.
    Schlenger, L.
    Agaoglu, D.
    Schild, R.
    Budach, V
    STRAHLENTHERAPIE UND ONKOLOGIE, 2008, 184 : 59 - 59
  • [10] THE NEUROSTATION SYSTEM FOR IMAGE-GUIDED, FRAMELESS STEREOTAXY
    GERMANO, IM