Tri-linear interpolation-based cerebral white matter fiber imaging

被引:4
|
作者
Jiang, Shan [1 ]
Zhang, Pengfei [1 ]
Han, Tong [2 ]
Liu, Weihua [1 ]
Liu, Meixia [1 ]
机构
[1] Tianjin Univ, Sch Mech Engn, Tianjin 300072, Peoples R China
[2] Tianjin Huanhu Hosp, Med Image Evaluat Ctr, Tianjin 300060, Peoples R China
基金
中国国家自然科学基金;
关键词
neural regeneration; neuroimaging; diffusion tensor imaging; tri-linear interpolation; tensor algorithm; white matter fiber; fiber tracking; magnetic resonance imaging; grants-supported paper; neuroregeneration; DIFFUSION TENSOR MRI; CORPUS-CALLOSUM; CONNECTIVITY; TRACKING; NETWORKS;
D O I
10.3969/j.issn.1673-5374.2013.23.005
中图分类号
Q2 [细胞生物学];
学科分类号
071009 ; 090102 ;
摘要
Diffusion tensor imaging is a unique method to visualize white matter fibers three-dimensionally, non-invasively and in vivo, and therefore it is an important tool for observing and researching neural regeneration. Different diffusion tensor imaging-based fiber tracking methods have been already investigated, but making the computing faster, fiber tracking longer and smoother and the details shown clearer are needed to be improved for clinical applications. This study proposed a new fiber tracking strategy based on tri-linear interpolation. We selected a patient with acute infarction of the right basal ganglia and designed experiments based on either the tri-linear interpolation algorithm or tensorline algorithm. Fiber tracking in the same regions of interest (genu of the corpus callosum) was performed separately. The validity of the tri-linear interpolation algorithm was verified by quantitative analysis, and its feasibility in clinical diagnosis was confirmed by the contrast between tracking results and the disease condition of the patient as well as the actual brain anatomy. Statistical results showed that the maximum length and average length of the white matter fibers tracked by the tri-linear interpolation algorithm were significantly longer. The tracking images of the fibers indicated that this method can obtain smoother tracked fibers, more obvious orientation and clearer details. Tracking fiber abnormalities are in good agreement with the actual condition of patients, and tracking displayed fibers that passed though the corpus callosum, which was consistent with the anatomical structures of the brain. Therefore, the tri-linear interpolation algorithm can achieve a clear, anatomically correct and reliable tracking result.
引用
收藏
页码:2155 / 2164
页数:10
相关论文
共 50 条
  • [1] Tri-linear interpolation-based cerebral white matter fiber imaging
    Shan Jiang
    Pengfei Zhang
    Tong Han
    Weihua Liu
    Meixia Liu
    NeuralRegenerationResearch, 2013, 8 (23) : 2155 - 2164
  • [2] Camera calibration method of tri-linear interpolation error compensation
    Jilin University, Changchun 130025, China
    Nongye Jixie Xuebao/Transactions of the Chinese Society of Agricultural Machinery, 2008, 39 (10): : 187 - 190
  • [3] Fast tri-linear interpolation algorithm for volume rendering of medical images
    Zhuge, Bin
    Feng, Huan-Qing
    Zhou, He-Qin
    Hangtian Yixue Yu Yixue Gongcheng/Space Medicine and Medical Engineering, 2003, 16 (03):
  • [4] A regularized tri-linear approach for optical interferometric imaging
    Birdi, Jasleen
    Repetti, Audrey
    Wiaux, Yves
    MONTHLY NOTICES OF THE ROYAL ASTRONOMICAL SOCIETY, 2017, 468 (01) : 1142 - 1155
  • [5] White Matter Fiber Tracts Based On Diffusion Tensor Imaging
    Di, Qian
    Wang, Tingting
    Yao, Li
    Zhao, XiaoJie
    ICNC 2008: FOURTH INTERNATIONAL CONFERENCE ON NATURAL COMPUTATION, VOL 4, PROCEEDINGS, 2008, : 306 - 310
  • [6] Robust Fiber Clustering of Cerebral Fiber Bundles in White Matter
    Yao, Xufeng
    Wang, Yongxiong
    Zhuang, Songlin
    INTERNATIONAL SYMPOSIUM ON OPTOELECTRONIC TECHNOLOGY AND APPLICATION 2014: IMAGE PROCESSING AND PATTERN RECOGNITION, 2014, 9301
  • [7] Diffusion Tensor Imaging of Cerebral White Matter
    Stoeter, Peter
    Dellani, Paulo Roberto
    Vucurevic, Goran
    CLINICAL NEURORADIOLOGY, 2008, 18 (03) : 155 - 162
  • [8] White matter fiber tracking method by vector interpolation with diffusion tensor Imaging data in human brain
    Zhao, Xin
    Wang, Mingshi
    Gao, Wei
    Liu, Haiying
    2005 27TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2005, : 5786 - 5789
  • [9] Double Interpolation-Based Linear Fitting for OMP Channel Estimation in OFDM Systems
    Qiao, Gang
    Qiang, Xizhu
    Wan, Lei
    IEEE COMMUNICATIONS LETTERS, 2021, 25 (09) : 2908 - 2912
  • [10] Performance of linear interpolation-based MIMO detection for MIMO-OFDM systems
    Wang, JM
    Daneshrad, B
    2004 IEEE WIRELESS COMMUNICATIONS AND NETWORKING CONFERENCE, VOLS 1-4: BROADBAND WIRELESS - THE TIME IS NOW, 2004, : 981 - 986