Stator coil insulation for modern air-cooled generators

被引:1
|
作者
Emery, FT [1 ]
机构
[1] Siemens Westinghouse Power Corp, Ft Payne, AL 35967 USA
关键词
D O I
10.1109/EEIC.2001.965607
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Stator coils in modern air cooled generators are subject to high electrical, mechanical, and thermal stress. In addition, operation in the air environment doesn't offer the dielectric advantages of operating in high pressure hydrogen. These three insulation stress factors are well known and for the most part understood with respect to the factors taken into account when designing air cooled generator stator windings. These three stress factors are considered when selecting the coil materials, the coil geometry, and the rating capabilities of the stator coil. With the movement to increasing the power density of air-cooled generators, it has become more critical to be sure the design constraints are met in the stator coil design. In addition, the coil materials and processing must be improved to meet the demands of the increased stress factors. In addition to the use of high performance coil materials, great improvements have been made in the analysis, testing, and the use of more sosphicated instrumentation for verification testing. The stator coil insulation system used in the modern air cooled generators are designed to meet the high demands placed on the system during generator operation.
引用
收藏
页码:185 / 188
页数:4
相关论文
共 50 条
  • [1] Problems with modern air-cooled generator stator winding insulation
    Griffith, G
    Tucker, S
    Milsom, J
    Stone, G
    [J]. IEEE ELECTRICAL INSULATION MAGAZINE, 2000, 16 (06) : 6 - 10
  • [2] Stator Winding Partial Discharge Activity for Air-Cooled Generators
    Warren, Vicki
    [J]. 2012 OCEANS, 2012,
  • [3] Problems with modern air-cooled generator stator windings
    Tucker, S
    Milsom, J
    Griffith, G
    Stone, G
    [J]. INTERNATIONAL CONFERENCE ON POWER STATION MAINTENANCE 2000, 2000, 2000 (07): : 137 - 144
  • [4] Application of air-cooled generators to modern power plants
    Gott, BEB
    [J]. IEMDC'99 - IEEE INTERNATIONAL ELECTRIC MACHINES AND DRIVES CONFERENCE, PROCEEDINGS, 1999, : 317 - 319
  • [5] Excessive losses and temperature field calculation of stator coil bars in air-cooled large hydro-generators
    [J]. Du, C. (cx_du@chng.com.cn), 1600, Chinese Society for Electrical Engineering (32):
  • [6] Analysis of Insulation Diagnosis and Failure in Stator Windings of Air-Cooled Gas Turbine Generator
    Kim, Hee-Dong
    Kong, Tae-Sik
    [J]. 2014 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2014, : 1472 - 1475
  • [7] Research on Stator Main Insulation Temperature Field of Air-Cooled Turbo-Generator after Main Insulation Shelling
    Li, Weili
    Li, Yong
    Su, Ying
    Wang, Purui
    Liu, Wenmao
    [J]. ENERGIES, 2018, 11 (05)
  • [8] PYROLYSIS OF STATOR COIL INSULATION IN AIR AND HYDROGEN
    FROMM, MM
    [J]. IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1967, PA86 (09): : 1102 - &
  • [9] Open Air-Cooled Generators for the Use in Wind Turbines
    Zeichfuessl, Roland
    Oberneder, Manuel
    Joeckel, Andreas
    [J]. 2019 CONFERENCE FOR WIND POWER DRIVES (CWD 2019), 2019,
  • [10] Air-cooled generators for gas turbine power plants
    [J]. Diesel & Gas Turbine Worldwide, 1997, 29 (08):