Application of a multi-channel system for continuous monitoring and an early warning system

被引:8
|
作者
Lee, J. H.
Song, C. H.
Kim, B. C.
Gu, M. B.
机构
[1] Gwangju Inst Sci & Technol, ADEMRG, Kwangju 500712, South Korea
[2] Korea Univ, Coll Life Sci & Biotechnol, Seoul 136701, South Korea
关键词
continuous monitoring; early warning system; recombinant bioluminescent bacteria; remote sensing; toxicity classification;
D O I
10.2166/wst.2006.139
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
A multi-channel continuous toxicity monitoring system developed in our laboratory, based on two-stage mini-bioreactors, was successfully implemented in the form of computer-based data acquisition. The multi-channel system consists of a series of a two-stage minibioreactor systems connected by a fiber optic probe to a luminometer, and uses genetically engineered bioluminescent bacteria for the detection of the potential toxicity from the soluble chemicals. This system can be stably and continuously operated due to the separation of the culture reactor from the test reactor and accomplish easy and long-term monitoring without system shut down by abrupt inflows of severe polluting chemicals. Four different recombinant bioluminescent bacteria were used in different channels so that the modes of the samples toxicities can be reasonably identified and evaluated based upon the response signature of each channel. The bioluminescent signatures were delivered from four channels by switching one at once, while the data is automatically logged to an IBM compatible computer. We also achieved the enhancement of the system through the manipulation of the dilution rate and the use of thermo-lux fusion strains. Finally, this system is now being implemented to a drinking water reservoir and river for remote sensing as an early warning system,
引用
收藏
页码:341 / 346
页数:6
相关论文
共 50 条
  • [1] Application of a multi-channel system for continuous monitoring and an early warning system (vol 53, pg 341, 2006)
    Lee, J. H.
    Song, C. H.
    Kim, B. C.
    Gu, M. B.
    [J]. WATER SCIENCE AND TECHNOLOGY, 2006, 54 (11-12) : 445 - 445
  • [2] Design of Multi-Channel Weighting Monitoring System
    Shi Lilian
    Xu Guoxing
    Shen Hongwei
    Ye Jun
    [J]. PROCEEDINGS OF THE THIRD INTERNATIONAL SYMPOSIUM ON TEST AUTOMATION & INSTRUMENTATION, VOLS 1 - 4, 2010, : 1275 - 1278
  • [3] Realization and Technology Acceptance Test of a Wearable Cardiac Health Monitoring and Early Warning System with Multi-Channel MCGs and ECG
    Lin, Wen-Yen
    Ke, Hong-Lin
    Chou, Wen-Cheng
    Chang, Po-Cheng
    Tsai, Tsai-Hsuan
    Lee, Ming-Yih
    [J]. SENSORS, 2018, 18 (10)
  • [4] A Cardiac Early Warning System with Multi Channel SCG and ECG Monitoring for Mobile Health
    Sahoo, Prasan Kumar
    Thakkar, Hiren Kumar
    Lee, Ming-Yih
    [J]. SENSORS, 2017, 17 (04)
  • [5] A multi-channel continuous water toxicity monitoring system: Its evaluation and application to water discharged from a power plant
    Kim, BC
    Gu, MB
    [J]. ENVIRONMENTAL MONITORING AND ASSESSMENT, 2005, 109 (1-3) : 123 - 133
  • [6] A Multi-Channel Continuous Water Toxicity Monitoring System: Its Evaluation and Application to Water Discharged from a Power Plant
    Byoung Chan Kim
    Man Bock Gu
    [J]. Environmental Monitoring and Assessment, 2005, 109 : 123 - 133
  • [7] A multi-channel continuous toxicity monitoring system using recombinant bioluminescent bacteria for classification of toxicity
    Gu, MB
    Gil, GC
    [J]. BIOSENSORS & BIOELECTRONICS, 2001, 16 (9-12): : 661 - 666
  • [8] Enhancement of the multi-channel continuous monitoring system through the use of Xenorhabdus luminescens lux fusions
    Lee, JH
    Mitchell, RJ
    Gu, MB
    [J]. BIOSENSORS & BIOELECTRONICS, 2004, 20 (03): : 475 - 481
  • [9] Design of Multi-channel analyzer's monitoring system based on embedded system
    Yang, Tao
    Wei, Yi-Xiang
    [J]. Hedianzixue Yu Tance Jishu/Nuclear Electronics and Detection Technology, 2007, 27 (04): : 745 - 747
  • [10] A multi-channel monitoring system for system-wide power quality measurements
    Chen, S
    Zhang, CL
    Liu, YZ
    [J]. 2000 INTERNATIONAL CONFERENCE ON POWER SYSTEM TECHNOLOGY, VOLS I-III, PROCEEDINGS, 2000, : 953 - 958