Wide-area measurement signal-based stabiliser for large-scale photovoltaic plants with high variability and uncertainty

被引:35
|
作者
Shah, Rakibuzzaman [1 ]
Mithulananthan, Nadarajah [1 ]
Lee, Kwang Y. [2 ]
Bansal, Ramesh C. [3 ]
机构
[1] Univ Queensland, Sch Informat Technol & Elect Engn, Brisbane, Qld 4072, Australia
[2] Baylor Univ, Dept Elect & Comp Engn, Waco, TX 76798 USA
[3] Univ Petoria, Dept Elect Elect & Comp Engn, Petoria, South Africa
关键词
control system synthesis; damping; feedback; Gaussian processes; hybrid power systems; matrix algebra; photovoltaic power systems; power generation control; power system measurement; probability; synchronous generators; wide-area measurement signal-based stabiliser; large-scale photovoltaic plant; norm bounded linear quadratic Gaussian controller synthesis method; WAMS; power oscillation damping controller; PV plant; matrices system; convex polytopic region; hybrid power system; Hankel singular value; HSV; right-half-plane zero utilization; RHP-zero utilization; optimal feedback signal selection; subsystem delay; modal interaction measurement; probabilistic distribution; synchronous generator; 16 machine test system; 68 bus test system; controllability-observability method; geometric measurement; POWER; SELECTION; DESIGN;
D O I
10.1049/iet-rpg.2013.0046
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
In this study, norm bounded linear quadratic Gaussian controller synthesis method is utilised to design a wide-area measurement signal (WAMS)-based power oscillation damping controller at photovoltaics (PV) plants. The uncertainties associated with the system are confined by the system matrices which are the affine functions of parameters belong to a convex polytopic region. A hybrid method based on Hankel singular value (HSV) and right-half-plane zeros (RHP-zeros) is utilised to assess and select the optimal feedback signal for the PV wide-area damping controller. First, the HSVs of the delayed subsystems are employed to preselect the candidate signals for damping the target mode. Then, the RHP-zeros and the modal interaction measures of the candidate signals are evaluated. Finally, the signal with minimum variance in HSV and modal interaction over the wide range of operating conditions is selected as the optimal feedback signal for the controller design. The wide range of operating conditions is obtained by the probabilistic distribution of loads, synchronous generators and PVs. The approach has been tested on a large 16 machine, 68 bus test system as compared to geometric measures of controllability/observability method and has shown improved performance.
引用
收藏
页码:614 / 622
页数:9
相关论文
共 50 条
  • [1] Wide-area signal-based optimal neurocontroller for a UPFC
    Ray, Swakshar
    Venayagamoorthy, Ganesh K.
    [J]. IEEE TRANSACTIONS ON POWER DELIVERY, 2008, 23 (03) : 1597 - 1605
  • [2] Decentralized Measurement based Adaptive Wide-Area Damping Controller for a Large-scale Power System
    Yohanandhan, Rajaa Vikhram
    Srinivasan, Latha
    [J]. 2018 IEEE INTERNATIONAL CONFERENCE ON POWER ELECTRONICS, DRIVES AND ENERGY SYSTEMS (PEDES), 2018,
  • [3] Modeling and Optimizing Large-Scale Wide-Area Data Transfers
    Kettimuthu, Rajkumar
    Vardoyan, Gayane
    Agrawal, Gagan
    Sadayappan, P.
    [J]. 2014 14TH IEEE/ACM INTERNATIONAL SYMPOSIUM ON CLUSTER, CLOUD AND GRID COMPUTING (CCGRID), 2014, : 196 - 205
  • [4] AutoVFlow: Virtualization of large-scale wide-area OpenFlow networks
    Yamanaka, Hiroaki
    Kawai, Eiji
    Shimojo, Shinji
    [J]. COMPUTER COMMUNICATIONS, 2017, 102 : 28 - 46
  • [5] Wide-Area Measurement based Dynamic Stochastic Optimal Power Flow Control for Smart Grids with High Variability and Uncertainty
    Liang, Jiaqi
    Venayagamoorthy, Ganesh
    Harley, Ronald
    [J]. 2012 IEEE POWER AND ENERGY SOCIETY GENERAL MEETING, 2012,
  • [6] Wide-Area Measurement Based Dynamic Stochastic Optimal Power Flow Control for Smart Grids With High Variability and Uncertainty
    Liang, Jiaqi
    Venayagamoorthy, Ganesh K.
    Harley, Ronald G.
    [J]. IEEE TRANSACTIONS ON SMART GRID, 2012, 3 (01) : 59 - 69
  • [7] Wide-area damping controller design of large-scale PV power plants in interconnected power systems
    Ge, Jing
    Zhao, Da-wei
    Ma, Jin
    Wang, Yu-sheng
    Du, Hong-ji
    Qian, Min-hui
    [J]. 2016 CHINA INTERNATIONAL CONFERENCE ON ELECTRICITY DISTRIBUTION (CICED), 2016,
  • [8] A cluster-based networking approach for large-scale and wide-area quantum key agreement
    Li, Zhonghui
    Xue, Kaiping
    Jia, Qidong
    Li, Jian
    Wei, David S. L.
    Liu, Jianqing
    Yu, Nenghai
    [J]. QUANTUM INFORMATION PROCESSING, 2022, 21 (05)
  • [9] Building a Large-Scale and Wide-Area Quantum Internet Based on an OSI-Alike Model
    Zhonghui Li
    Kaiping Xue
    Jian Li
    Nenghai Yu
    Jianqing Liu
    David S.L.Wei
    Qibin Sun
    Jun Lu
    [J]. China Communications, 2021, 18 (10) : 1 - 14
  • [10] Building a Large-Scale and Wide-Area Quantum Internet Based on an OSI-Alike Model
    Li, Zhonghui
    Xue, Kaiping
    Li, Jian
    Yu, Nenghai
    Liu, Jianqing
    Wei, David S. L.
    Sun, Qibin
    Lu, Jun
    [J]. CHINA COMMUNICATIONS, 2021, 18 (10) : 1 - 14