Highly sensitive immunoradiometric assay for serum thyroglobulin with minimal interference from autoantibodies

被引:0
|
作者
Marquet, PY
Daver, A
Sapin, R
Bridgi, B
Muratet, JP
Hartmann, DJ
Paolucci, F
Pau, B
机构
[1] ERIA DIAGNOST PASTEUR, F-92430 MARNES COQUETTE, FRANCE
[2] CTR PAUL PAPIN, RADIO IMMUNOL LAB, F-49036 ANGERS, FRANCE
[3] FAC MED, INST PHYS BIOL, F-67085 STRASBOURG, FRANCE
[4] CTR HOSP, NUCL MED SERV, F-44035 NANTES, FRANCE
[5] INST PASTEUR LYON, UNITE PATHOL CELLULAIRE, CNRS, URA 1459, F-69365 LYON 7, FRANCE
[6] SANOFI RECH, F-34184 MONTPELLIER 4, FRANCE
[7] FAC PHARM MONTPELLIER, CNRS, UMR 9921, F-34060 MONTPELLIER 1, FRANCE
关键词
monoclonal antibodies; variation; source of; thyroid carcinoma;
D O I
暂无
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Five monoclonal antibodies (MAbs) directed against antigenic domains on thyroglobulin (Tg) not recognized by most anti-Tg human autoantibodies (aAbs) have been used to develop an improved IRMA for serum Tg with a limit of detection of 0.2 mu g/L. Samples are incubated for 3 h in tubes coated with four anti-Tg MAbs, After washing, the tubes are incubated with the tracer MAb for 20 h at room temperature, Dilution and reproducibility tests demonstrated assay reliability. Tests performed on samples with (n = 361) or without (n = 283) aAbs showed that the TG IRMA Pasteur is largely independent of the marked interference generally caused by aAbs, These results were confirmed with an extended population of 2759 samples. For a cutoff of 1 mu g/L, sensitivity and specificity were 0.97 and 1, respectively, in a follow-up of differentiated thyroid carcinoma in patients treated by total thyroidectomy.
引用
收藏
页码:258 / 262
页数:5
相关论文
共 50 条
  • [1] Characterization of a new highly sensitive immunometric assay for thyroglobulin with reduced interference from autoantibodies
    Broughton, Marianne Nordlund
    Nome, Ragnhild
    Sandven, Ingvill
    Paus, Elisabeth
    Bjoro, Trine
    TUMOR BIOLOGY, 2016, 37 (06) : 7729 - 7739
  • [2] A highly sensitive assay to detect thyroglobulin autoantibodies in undiluted serum samples.
    Pirens, G
    Maury, D
    Hennen, G
    Cloux, JL
    CLINICAL CHEMISTRY, 1997, 43 : 359 - 359
  • [3] AN IMMUNORADIOMETRIC ASSAY FOR MEASUREMENT OF SERUM THYROGLOBULIN
    RAJASHEKHARRAO, B
    KUMAR, A
    VELUMANI, A
    SHAH, DH
    INDIAN JOURNAL OF MEDICAL RESEARCH SECTION B-BIOMEDICAL RESEARCH OTHER THAN INFECTIOUS DISEASES, 1992, 96 : 350 - 355
  • [4] Thyroglobulin IRMA pasteur immunoassay: Sensitivity of the assay and interference from thyroglobulin autoantibodies
    Calzolari, C
    Marquet, PY
    Pau, B
    CLINICAL CHEMISTRY, 1997, 43 (02) : 413 - 414
  • [5] ASSAY OF THYROGLOBULIN IN SERUM WITH THYROGLOBULIN AUTOANTIBODIES - AN UNOBTAINABLE GOAL
    MARIOTTI, S
    BARBESINO, G
    CATUREGLI, P
    MARINO, M
    MANETTI, L
    PACINI, F
    CENTONI, R
    PINCHERA, A
    JOURNAL OF CLINICAL ENDOCRINOLOGY & METABOLISM, 1995, 80 (02): : 468 - 472
  • [6] Thyroglobulin IRMA pasteur immunoassay: Sensitivity of the assay and interference from thyroglobulin autoantibodies - Reply
    Spencer, CA
    Takeuchi, M
    CLINICAL CHEMISTRY, 1997, 43 (02) : 414 - 415
  • [7] Detection of thyroglobulin autoantibodies and assessment of their interference with serum thyroglobulin measurement
    Campino, C
    Arteaga, E
    Valdivia, L
    Foradori, A
    López, JM
    Poggi, H
    REVISTA MEDICA DE CHILE, 1999, 127 (06) : 667 - 674
  • [8] SENSITIVE ASSAY FOR THYROGLOBULIN AUTOANTIBODIES IN SERUM EMPLOYING POLYETHYLENE-GLYCOL FOR PRECIPITATION
    LAURBERG, P
    PEDERSEN, KM
    SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 1988, 48 (02): : 137 - 140
  • [9] NOVEL IMMUNORADIOMETRIC ASSAY OF THYROGLOBULIN IN SERUM WITH USE OF MONOCLONAL-ANTIBODIES SELECTED FOR LACK OF CROSS-REACTIVITY WITH AUTOANTIBODIES
    PIECHACZYK, M
    BALDET, L
    PAU, B
    BASTIDE, JM
    CLINICAL CHEMISTRY, 1989, 35 (03) : 422 - 424
  • [10] A SENSITIVE RADIOIMMUNOASSAY FOR SERUM THYROGLOBULIN - INCLUDING A CORRECT SCREENING FOR THYROGLOBULIN AUTOANTIBODIES
    LAURBERG, P
    PEDERSEN, KM
    SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 1987, 47 (07): : 685 - 689