Development and validation of a novel LC-MS/MS method for simultaneous quantitative determination of tyrosine kinase inhibitors in human plasma

被引:5
|
作者
Lou, Yutao [1 ,2 ]
Qin, Hui [1 ]
Hu, Qing [1 ]
Chai, Yitao [1 ]
Zhou, Hongying [3 ]
Chen, Mengting [1 ]
Wang, Qiyue [1 ]
Huang, Ping [1 ,4 ]
Gu, Jinping [2 ]
Zhang, Yiwen [1 ,2 ,4 ]
机构
[1] Affiliated Peoples Hosp, Clin Pharm Ctr, Dept Pharm, Zhejiang Prov Peoples Hosp,Hangzhou Med Coll, Hangzhou, Zhejiang, Peoples R China
[2] Zhejiang Univ Technol, Coll Pharm, Hangzhou 310014, Peoples R China
[3] Affiliated Peoples Hosp, Zhejiang Prov Peoples Hosp, Dept Oncol, Hangzhou Med Coll, Hangzhou, Zhejiang, Peoples R China
[4] Key Lab Endocrine Gland Dis, Hangzhou, Zhejiang, Peoples R China
关键词
Tyrosine kinase inhibitors; Liquid chromatography -tandem mass spectrometry; Single-step protein precipitation; Human plasma; Non -small cell lung cancer; MASS-SPECTROMETRY; QUANTIFICATION; CRIZOTINIB; PHARMACOKINETICS; CERITINIB; AFATINIB;
D O I
10.1016/j.jchromb.2022.123394
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The objective of this study was to develop and validate a simple, rapid, and sensitive liquid chromatography -tandem mass spectrometry (LC-MS/MS) method for the simultaneous determination of three tyrosine kinase inhibitors (ceritinib, osimertinib, and crizotinib) in human plasma using a single-step protein precipitation extraction. Chromatographic separation was achieved using a Waters X Bridge C18 (2.1 mm x 100 mm, 3.5 mu m) and gradient elution with 0.2 % formic acid in water and acetonitrile. The total run time was 4.0 min, and the injection volume was 5 mu L. The analytes were detected in the multiple reaction monitoring mode using elec-trospray ionization with positive ion mode. The m/z transitions of ceritinib, osimertinib, crizotinib and nilotinib were 558.0 -> 433.2, 500.0 -> 72.1, 450.0 -> 259.3, and 530.0 -> 289.1, respectively. The method was linear in the range of 2-500 ng/mL with lower limit of quantification of 2 ng/mL. Based on the guidelines on bioanalytical methods by the FDA, the validation studies demonstrated that the three analytes were both precise and accurate at four concentration levels, and the coefficient of variation was < 10.59 % and accuracy was > 88.26 %. We present a simple, rapid, and sensitive method for the simultaneous quantification of ceritinib, osimertinib, and crizotinib in human plasma by LC-MS/MS, which could be used in routine therapeutic drug monitoring.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Development and Validation of a Simultaneous Quantification Method of 14 Tyrosine Kinase Inhibitors in Human Plasma Using LC-MS/MS
    Huynh, Huu H.
    Pressiat, Claire
    Sauvageon, Helene
    Madelaine, Isabelle
    Maslanka, Patricia
    Lebbe, Celeste
    Thieblemont, Catherine
    Goldwirt, Lauriane
    Mourah, Samia
    [J]. THERAPEUTIC DRUG MONITORING, 2017, 39 (01) : 43 - 54
  • [2] Development and clinical application of a LC-MS/MS method for simultaneous determination of various tyrosine kinase inhibitors in human plasma
    Goetze, Lutz
    Hegele, Axel
    Metzelder, Stephan Klaus
    Renz, Harald
    Nockher, Wolfgang Andreas
    [J]. CLINICA CHIMICA ACTA, 2012, 413 (1-2) : 143 - 149
  • [3] Development and validation of a quantitative LC-MS/MS method for the simultaneous determination of ceftolozane and tazobactam in human plasma and urine
    Putnam, William C.
    Kallem, Raja Reddy
    Edpuganti, Vindhya
    Subramaniyan, Indhu
    Hall, Ronald G., II
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2020, 1159
  • [4] Development and validation of an LC-MS/MS method for the simultaneous determination of bedaquiline and rifabutin in human plasma
    Gray, Wesley A.
    Waldorf, Byron
    Rao, Manasa Geeta
    Stiles, Brenda L.
    Griffiss, J. McLeod
    Salata, Robert A.
    Blumer, Jeffrey L.
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2019, 176
  • [5] A NEW LC-MS/MS METHOD FOR THE ANALYSIS OF TYROSINE KINASE INHIBITORS IN HUMAN PLASMA
    Goetze, L.
    Renz, H.
    Nockher, W. A.
    [J]. CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2011, 49 : S239 - S239
  • [6] LC-MS/MS Method Development and Validation for the Determination of Nifedipine in Human Plasma
    Logoyda, Liliya S.
    [J]. BIOINTERFACE RESEARCH IN APPLIED CHEMISTRY, 2020, 10 (05): : 6220 - 6227
  • [7] Development and validation of a LC-MS/MS method for the determination of viaminate in human plasma
    Yin, Jing
    Ni, Kun-Yi
    Shen, Yue
    Ma, Peng-Cheng
    Cao, Ling
    Wang, Wei-Peng
    Wang, Yu
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2007, 856 (1-2): : 376 - 380
  • [8] Development and Validation of LC-MS/MS Method for Simultaneous Determination of Metformin and Four Gliptins in Human Plasma
    Al Bratty, Mohammed
    Alhazmi, Hassan A.
    Javed, Sadique Akhtar
    Lalitha, Keddal G.
    Asmari, Mufarreh
    Woelker, Jessica
    El Deeb, Sami
    [J]. CHROMATOGRAPHIA, 2017, 80 (06) : 891 - 899
  • [9] Development and validation of LC-MS/MS method for quantitative determination of (-)-securinine in mouse plasma
    Wabuyele, Simuli L.
    Wald, David
    Xu, Yan
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2014, 960 : 19 - 26
  • [10] Development and Validation of an LC-MS/MS Method for the Quantitative Determination of Contezolid in Human Plasma and Cerebrospinal Fluid
    Zhang, Guanxuanzi
    Zhang, Na
    Dong, Liuhan
    Bai, Nan
    Cai, Yun
    [J]. PHARMACEUTICALS, 2023, 16 (01)