Fluence map optimization (FMO) with dose-volume constraints in IMRT using the geometric distance sorting method

被引:3
|
作者
Lan, Yihua [1 ]
Li, Cunhua [1 ]
Ren, Haozheng [1 ]
Zhang, Yong [1 ]
Min, Zhifang [2 ]
机构
[1] Huaihai Inst Technol, Sch Comp Engn, Lianyungang 222005, Jiangsu, Peoples R China
[2] Huazhong Inst Optoelect, Dept Syst, Wuhan 430074, Hubei, Peoples R China
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2012年 / 57卷 / 20期
基金
中国国家自然科学基金;
关键词
MULTIPLE LOCAL MINIMA; RADIATION-THERAPY;
D O I
10.1088/0031-9155/57/20/6407
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A new heuristic algorithm based on the so-called geometric distance sorting technique is proposed for solving the fluence map optimization with dose-volume constraints which is one of the most essential tasks for inverse planning in IMRT. The framework of the proposed method is basically an iterative process which begins with a simple linear constrained quadratic optimization model without considering any dose-volume constraints, and then the dose constraints for the voxels violating the dose-volume constraints are gradually added into the quadratic optimization model step by step until all the dose-volume constraints are satisfied. In each iteration step, an interior point method is adopted to solve each new linear constrained quadratic programming. For choosing the proper candidate voxels for the current dose constraint adding, a so-called geometric distance defined in the transformed standard quadratic form of the fluence map optimization model was used to guide the selection of the voxels. The new geometric distance sorting technique can mostly reduce the unexpected increase of the objective function value caused inevitably by the constraint adding. It can be regarded as an upgrading to the traditional dose sorting technique. The geometry explanation for the proposed method is also given and a proposition is proved to support our heuristic idea. In addition, a smart constraint adding/deleting strategy is designed to ensure a stable iteration convergence. The new algorithm is tested on four cases including head-neck, a prostate, a lung and an oropharyngeal, and compared with the algorithm based on the traditional dose sorting technique. Experimental results showed that the proposed method is more suitable for guiding the selection of new constraints than the traditional dose sorting method, especially for the cases whose target regions are in non-convex shapes. It is a more efficient optimization technique to some extent for choosing constraints than the dose sorting method. By integrating a smart constraint adding/deleting scheme within the iteration framework, the new technique builds up an improved algorithm for solving the fluence map optimization with dose-volume constraints.
引用
收藏
页码:6407 / 6428
页数:22
相关论文
共 50 条
  • [1] A Novel Method for Fluence Map Optimization with Dose Volume Constraints in IMRT
    Ren, Haozheng
    Lan, Yihua
    Li, Cunhua
    Zhao, Xuefeng
    Min, Zhifang
    [J]. APPLIED INFORMATICS AND COMMUNICATION, PT I, 2011, 224 : 582 - +
  • [2] A Novel Method for Fluence Map Optimization with Dose Volume Constraints in IMRT
    Ren, Haozheng
    Lan, Yihua
    Li, Cunhua
    Zhao, Xuefeng
    Min, Zhifang
    [J]. 2010 THE 3RD INTERNATIONAL CONFERENCE ON COMPUTATIONAL INTELLIGENCE AND INDUSTRIAL APPLICATION (PACIIA2010), VOL I, 2010, : 342 - 345
  • [3] A Bregman Iteration Method for IMRT Optimization with Dose-Volume Histogram Constraints
    Jia, X.
    Uribe-Sanchez, A.
    Jiang, S.
    [J]. MEDICAL PHYSICS, 2012, 39 (06) : 3921 - 3921
  • [4] An efficient relaxation method for dose-volume constraints in IMRT
    Choi, B
    Deasy, J
    [J]. MEDICAL PHYSICS, 2002, 29 (06) : 1255 - 1255
  • [5] A Novel Computationally Tractable Algorithm to Integrate Soft and Hard Dose-Volume Constraints Into IMRT Fluence Optimization
    Mukherjee, S.
    Hong, L.
    Deasy, J.
    Zarepisheh, M.
    [J]. MEDICAL PHYSICS, 2019, 46 (06) : E181 - E181
  • [6] A Computationally Efficient Algorithm for Integrating Dose-Volume Constraints Into IMRT Fluence Optimization for Automated Treatment Planning
    Mukherjee, S.
    Hong, L.
    Deasy, J.
    Zarepisheh, M.
    [J]. MEDICAL PHYSICS, 2018, 45 (06) : E444 - E444
  • [7] A Nonconvex Optimization Approach to IMRT Planning with Dose-Volume Constraints
    Maass, Kelsey
    Kim, Minsun
    Aravkin, Aleksandr
    [J]. INFORMS JOURNAL ON COMPUTING, 2022, 34 (03) : 1366 - 1386
  • [8] An Integrate Strategy: Combination of Biological and Dose-Volume Constraints in IMRT Optimization
    Feng, Z.
    Tao, C.
    Zhu, J.
    Chen, J.
    Yu, G.
    Qin, S.
    Yin, Y.
    [J]. MEDICAL PHYSICS, 2017, 44 (06) : 2901 - 2902
  • [9] Integrating soft and hard dose-volume constraints into hierarchical constrained IMRT optimization
    Mukherjee, Sovanlal
    Hong, Linda
    Deasy, Joseph O.
    Zarepisheh, Masoud
    [J]. MEDICAL PHYSICS, 2020, 47 (02) : 414 - 421
  • [10] Strong valid inequalities for fluence map optimization problem under dose-volume restrictions
    Ali T. Tuncel
    Felisa Preciado
    Ronald L. Rardin
    Mark Langer
    Jean-Philippe P. Richard
    [J]. Annals of Operations Research, 2012, 196 : 819 - 840