Development of a TB green II-based duplex real-time fluorescence quantitative PCR assay for the simultaneous detection of porcine circovirus 2 and 3

被引:23
|
作者
Zhao, Yu [1 ]
Han, Hao-ying [1 ]
Fan, Lin [1 ]
Tian, Run-Bo [1 ]
Cui, Jian-Tao [1 ]
Li, Jing-Yi [1 ]
Chen, Hong-Ying [1 ]
Yang, Ming-Fan [1 ]
Zheng, Lan-Lan [1 ]
机构
[1] Henan Agr Univ, Coll Anim Sci & Vet Med, Zhengzhou Key Lab Pig Dis Prevent & Control, Zhengdong New Dist Longzi Lake 15, Zhengzhou 450046, Henan, Peoples R China
关键词
Porcine circovirus; PCV2; PCV3; Quantitative real-time polymerase chain reaction; Epidemiology; GENETIC-CHARACTERIZATION; GENOME CHARACTERIZATION; PHYLOGENETIC ANALYSIS; RESPIRATORY-DISEASE; TYPE-3; PIGS; PCV3; SEQUENCE; REVEALS;
D O I
10.1016/j.mcp.2019.04.001
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Porcine circovirus 3 (PCV3), as a newly emerged circovirus, is widely distributed in pig populations worldwide. Co-infection of PCV2 and PCV3 has been reported frequently in clinical samples. In the present study, a TB Green II-based duplex real-time polymerase chain reaction (qPCR) was developed to rapidly and differentially detect PCV2 and PCV3. The assay specifically detected PCV2 and PCV3, with no fluorescence signals being detected for other non-targeted pig pathogens. The duplex qPCR showed a high degree of linearity (R-2 > 0.998), and its limits of detection were 10 and 78 copies/mu L for PCV2 and PCV3, respectively. The duplex qPCR could detect and differentiate PCV2 (melting peaks at 85.5 degrees C) and PCV3 (melting peaks at 82.5 degrees C), and showed high repeatability and reproducibility, with intra- and inter-assay coefficients of variation of less than 2.0%. Fifty-six tissue samples from 18 pig farms were used to evaluate the duplex qPCR method. The results revealed infection rates of 66.07% (37/56) and 39.28% (22/56) for PCV2 and PCV3, respectively. The PCV2 + PCV3 co-infection rate was 39.28% (22/56). The developed method could be used as an efficient molecular biology tool for epidemiological investigations of PCV2 and PCV3.
引用
收藏
页码:31 / 36
页数:6
相关论文
共 50 条
  • [1] A Duplex Real-Time PCR Assay for the Simultaneous Detection of Porcine Circovirus 2 and Circovirus 3
    Li, Xiangdong
    Qiao, Mingming
    Sun, Ming
    Tian, Kegong
    VIROLOGICA SINICA, 2018, 33 (02) : 181 - 186
  • [2] A Duplex Real-Time PCR Assay for the Simultaneous Detection of Porcine Circovirus 2 and Circovirus 3
    Xiangdong Li
    Mingming Qiao
    Ming Sun
    Kegong Tian
    Virologica Sinica, 2018, (02) : 181 - 186
  • [3] A Duplex Real-Time PCR Assay for the Simultaneous Detection of Porcine Circovirus 2 and Circovirus 3
    Xiangdong Li
    Mingming Qiao
    Ming Sun
    Kegong Tian
    Virologica Sinica, 2018, 33 (02) : 181 - 186
  • [4] Development of a SYBR green I-based duplex real-time fluorescence quantitative PCR assay for the simultaneous detection of porcine epidemic diarrhea virus and porcine circovirus 3
    Han, Hao-Ying
    Zheng, Hui-Hua
    Zhao, Yu
    Tian, Run-Bo
    Xu, Peng-Li
    Hou, Hua-Lin
    Chen, Hong-Ying
    Yang, Ming-Fan
    MOLECULAR AND CELLULAR PROBES, 2019, 44 : 44 - 50
  • [5] Simultaneous detection of classical swine fever virus and porcine circovirus 3 by SYBR green I-based duplex real-time fluorescence quantitative PCR
    Zheng, Hui-Hua
    Zhang, Shu-Jian
    Cui, Jian-Tao
    Zhang, Jia
    Wang, Leyi
    Liu, Fang
    Chen, Hong-Ying
    MOLECULAR AND CELLULAR PROBES, 2020, 50
  • [6] Development of a SYBR green I-based duplex real-time PCR assay for detection of pseudorabies virus and porcine circovirus 3
    Tian, Run-Bo
    Jin, Yue
    Xu, Tong
    Zhao, Yu
    Wang, Zhen-Ya
    Chen, Hong-Ying
    MOLECULAR AND CELLULAR PROBES, 2020, 53
  • [7] Development of a Real-Time Quantitative PCR Assay for Detection of Porcine Circovirus Type 2e
    Wen, Xiaohui
    Lv, Dianhong
    Zhai, Qi
    Zhou, Xiurong
    Gondal, Mushtaq Ahmad
    Nazar, Mudassar
    Saleem, Muhammad Usman
    Jia, Chunling
    Zhai, Shao-Lun
    PAKISTAN VETERINARY JOURNAL, 2022, 42 (03) : 429 - 432
  • [8] Development and validation of a duplex real-time PCR assay for the simultaneous detection and quantification of porcine circovirus type 2 and an internal control on porcine semen samples
    Pal, N.
    Huang, Y. W.
    Madson, D. M.
    Kuster, C.
    Meng, X. J.
    Halbur, P. G.
    Opriessnig, T.
    JOURNAL OF VIROLOGICAL METHODS, 2008, 149 (02) : 217 - 225
  • [9] Development of a Plexor real-time PCR assay for the detection of porcine circovirus type 2
    Vlasakova, Michaela
    Jackova, Anna
    Leskova, Valeria
    Vilcek, Stefan
    JOURNAL OF VIROLOGICAL METHODS, 2012, 179 (02) : 311 - 315
  • [10] Simultaneous detection of porcine reproductive and respiratory syndrome virus and porcine circovirus 3 by SYBR Green I-based duplex real-time PCR
    Zheng, Lan-lan
    Chai, Lv-ye
    Tian, Run-bo
    Zhao, Yu
    Chen, Hong-Ying
    Wang, Zhen-ya
    MOLECULAR AND CELLULAR PROBES, 2020, 49