Highly excited quadrupole lenses have significant spherical aberrations and they are very sensitive to the beam entrance angle, and microprobe size may vary considerably during scanning if the scanner is placed before or inside the focusing system. The effect of probe blurring while moving away from the optical axis can be partially compensated by adopting a dynamic focusing procedure to systems of magnetic quadrupole lenses like it is in electron beam devices. Dynamic focusing implies changing of quadrupole lens currents synchronously with the beam deflection on the certain rule such that probe size remains minimal in any raster point. A quadruplet of magnetic quadrupole lenses was considered. (c) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:21 / 24
页数:4
相关论文
共 50 条
  • [1] SCANNING PROTON MICROPROBE FACILITY WITH SUPERCONDUCTING LENS FOCUSING AND QUANTITATIVE RASTER SCANNING
    GRODZINS, L
    ARONSON, M
    HOROWITZ, P
    [J]. BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1978, 23 (08): : 1034 - 1035
  • [2] The effect of magnetic quadrupole lens hysteresis on the focusing of an ion beam with variable energy in a nuclear scanning microprobe
    Romanenko, A. V.
    Ponomarev, A. G.
    [J]. TECHNICAL PHYSICS LETTERS, 2013, 39 (04) : 317 - 320
  • [3] The effect of magnetic quadrupole lens hysteresis on the focusing of an ion beam with variable energy in a nuclear scanning microprobe
    A. V. Romanenko
    A. G. Ponomarev
    [J]. Technical Physics Letters, 2013, 39 : 317 - 320
  • [4] MICROMAGNETIC SCANNING MICROPROBE SYSTEM
    THOMPSON, CA
    CROSS, RW
    KOS, AB
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 1994, 65 (02): : 383 - 389
  • [5] Electrostatic Focusing Lens System for Low MeV-Ion Microprobe: A Simulation and Optimization Study
    Arya, H.
    Chirayath, V.
    Chi, Y.
    [J]. MEDICAL PHYSICS, 2021, 48 (06)
  • [6] Electrostatic focusing lens system for low MeV-ion microprobe: A simulation and optimization study
    Arya, Harsh
    Chirayath, Varghese A.
    Jin, Mingwu
    Weiss, Alex H.
    Glass, Gary A.
    Chi, Yujie
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2022, 518 : 7 - 14
  • [7] An Artificial Lens Capsule with a Lens Radial Stretching System Mimicking Dynamic Eye Focusing
    Wei, Huidong
    Wolffsohn, James S.
    Gomes de Oliveira, Otavio
    Davies, Leon N.
    [J]. POLYMERS, 2021, 13 (20)
  • [8] A MICROPROBE SYSTEM WITH A COMPACT ELECTROSTATIC LENS
    OGAWA, M
    OKUDA, K
    SANEYOSHI, K
    HIDAKA, K
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1985, 239 (03): : 455 - 458
  • [9] Improvement of the Scanning Performance of the Extended Hemispherical Integrated Lens Antenna Using a Double Lens Focusing System
    Nguyen, N. T.
    Boriskin, A. V.
    Le Coq, L.
    Sauleau, R.
    [J]. IEEE TRANSACTIONS ON ANTENNAS AND PROPAGATION, 2016, 64 (08) : 3698 - 3702
  • [10] A COMPUTER-CONTROLLED MAGNETIC POST-LENS SCANNING SYSTEM FOR THE LUND PROTON MICROPROBE
    TAPPER, UAS
    LOVESTAM, NEG
    KARLSSON, E
    MALMQVIST, KG
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1987, 28 (02): : 317 - 324