Comparison between active (pumped) and passive (diffusive) sampling methods for formaldehyde in pathology and histology laboratories

被引:15
|
作者
Lee, Eun Gyung [1 ]
Magrm, Rana [2 ]
Kusti, Mohannad [1 ]
Kashon, Michael L. [3 ]
Guffey, Steven [2 ]
Costas, Michelle M. [4 ]
Boykin, Carie J. [4 ]
Harper, Martin [1 ]
机构
[1] NIOSH, HELD, Exposure Assessment Branch, 1095 Willowdale Rd, Morgantown, WV 26505 USA
[2] West Virginia Univ, Ind & Management Syst Engn, Morgantown, WV USA
[3] NIOSH, HELD, Biostat & Epidemiol Branch, Morgantown, WV USA
[4] West Virginia Univ, Sch Med, Morgantown, WV USA
关键词
2,4-dinitrophenylhydrazine (DNPH); active sampling; formaldehyde; passive sampling; pathology/histology laboratory; CONCORDANCE CORRELATION-COEFFICIENT; CARBONYL-COMPOUNDS; ALDEHYDES; AGREEMENT; SAMPLERS;
D O I
10.1080/15459624.2016.1211284
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This study was to determine occupational exposures to formaldehyde and to compare concentrations of formaldehyde obtained by active and passive sampling methods. In one pathology and one histology laboratories, exposure measurements were collected with sets of active air samplers (Supelco LpDNPH tubes) and passive badges (ChemDisk Aldehyde Monitor 571). Sixty-six sample pairs (49 personal and 17 area) were collected and analyzed by NIOSH NMAM 2016 for active samples and OSHA Method 1007 (using the manufacturer's updated uptake rate) for passive samples. All active and passive 8-hr time-weighted average (TWA) measurements showed compliance with the OSHA permissible exposure limit (PEL-0.75 ppm) except for one passive measurement, whereas 78% for the active and 88% for the passive samples exceeded the NIOSH recommended exposure limit (REL-0.016 ppm). Overall, 73% of the passive samples showed higher concentrations than the active samples and a statistical test indicated disagreement between two methods for all data and for data without outliers. The OSHA Method cautions that passive samplers should not be used for sampling situations involving formalin solutions because of low concentration estimates in the presence of reaction products of formaldehyde and methanol (a formalin additive). However, this situation was not observed, perhaps because the formalin solutions used in these laboratories included much less methanol (3%) than those tested in the OSHA Method (up to 15%). The passive samplers in general overestimated concentrations compared to the active method, which is prudent for demonstrating compliance with an occupational exposure limit, but occasional large differences may be a result of collecting aerosolized droplets or splashes on the face of the samplers. In the situations examined in this study the passive sampler generally produces higher results than the active sampler so that a body of results from passive samplers demonstrating compliance with the OSHA PEL would be a valid conclusion. However, individual passive samples can show lower results than a paired active sampler so that a single result should be treated with caution.
引用
收藏
页码:31 / 39
页数:9
相关论文
共 50 条
  • [1] Comparison of quantitative airborne fungi measurements by active and passive sampling methods
    Yamamoto, Naomichi
    Schmechel, Detlef
    Chen, Bean T.
    Lindsley, William G.
    Peccia, Jordan
    [J]. JOURNAL OF AEROSOL SCIENCE, 2011, 42 (08) : 499 - 507
  • [2] Air sampling procedures to evaluate microbial contamination: a comparison between active and passive methods in operating theatres
    Christian Napoli
    Vincenzo Marcotrigiano
    Maria Teresa Montagna
    [J]. BMC Public Health, 12
  • [3] Air sampling procedures to evaluate microbial contamination: a comparison between active and passive methods in operating theatres
    Napoli, Christian
    Marcotrigiano, Vincenzo
    Montagna, Maria Teresa
    [J]. BMC PUBLIC HEALTH, 2012, 12
  • [4] Comparison of passive and active sampling methods for the determination of nitrogen dioxide in urban air
    Royset, O
    [J]. FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1998, 360 (01): : 69 - 73
  • [5] Comparison of passive and active sampling methods for the determination of nitrogen dioxide in urban air
    Oddvar Røyset
    [J]. Fresenius' Journal of Analytical Chemistry, 1998, 360 : 69 - 73
  • [6] A COMPARISON OF ACTIVE AND PASSIVE SAMPLING DEVICES FOR FULL-SHIFT AND SHORT-TERM MONITORING OF FORMALDEHYDE
    NOBLE, JS
    STRANG, CR
    MICHAEL, PR
    [J]. AMERICAN INDUSTRIAL HYGIENE ASSOCIATION JOURNAL, 1993, 54 (12): : 723 - 732
  • [7] Comparison between passive and active samplers for the determination of formaldehyde in indoor air by field test
    Kitami, H
    Watanabe, T
    Kitahara, T
    Ishihara, Y
    Takano, J
    [J]. BUNSEKI KAGAKU, 2003, 52 (10) : 945 - 949
  • [8] BTX measurements with diffusive samplers in the vicinity of a cokery: Comparison between ORSA-type samplers and pumped sampling
    Pfeffer, HU
    Breuer, L
    [J]. JOURNAL OF ENVIRONMENTAL MONITORING, 2000, 2 (05): : 483 - 486
  • [9] Diffusive uptake in passive and active adsorbent sampling using thermal desorption tubes
    Batterman, S
    Metts, T
    Kalliokoski, P
    [J]. JOURNAL OF ENVIRONMENTAL MONITORING, 2002, 4 (06): : 870 - 878
  • [10] Process intensification in carbonylation of formaldehyde with active and passive enhancement methods
    Zhihao Zhu
    Guodong Kang
    Sha Yu
    Yitian Qin
    Ying Sun
    Yiming Cao
    [J]. Journal of Flow Chemistry, 2020, 10 : 605 - 613