Chemiluminescence determination of tetracyclines using a tris(2,2′-bipyridine)ruthenium(II) and potassium permanganate system

被引:33
|
作者
Han, HY [1 ]
He, ZK [1 ]
Zeng, Y [1 ]
机构
[1] Wuhan Univ, Dept Chem, Wuhan 430072, Peoples R China
关键词
chemiluminescence; tris(2,2 '-bipyridine)ruthenium(II); tetracyclines; potassium permanganate;
D O I
10.2116/analsci.15.467
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A chemiluminescence method for the determination of tetracyclines was developed. The method is based on an enhancement of tetracyclines upon the chemiluminescence light emission of tris(2,2'-bipyridine)ruthenium(II). In a sulfuric acid medium, chemiluminescence light emission is generated upon continuous oxidation of tris(2,2'-bipyridine)ruthenium(II) by potassium permanganate, catalyzed by Mn(II). The light-emission intensity is enhanced when the tetracyclines are also present in the reaction system. Under the optimum conditions, the calibration curves are linear over the range 1.0x10(-7)-1.0x10(-5) g/ml for tetracycline, 4.0x10(-8)-1.0x10(-5) g/ml for chlortetracycline and 1.0x10(-7)-1.0x10(-5) g/ml for oxytetracycline. The limits of detection (S/N=S) are 2.0x10(-8) g/ml for tetracycline, 1.0x10(-8) g/ml for chlortetracycline and 2.0x10(-8) g/ml for oxytetracycline. The proposed method was used to determine tetracyclines in pharmaceutical formulations with good results.
引用
收藏
页码:467 / 470
页数:4
相关论文
共 50 条
  • [1] Chemiluminescence Determination of Tetracyclines Using a Tris(2,2′-bipyridine)ruthenium(II) and Potassium Permanganate System
    Heyou Han
    Zhike He
    Yun’e Zeng
    Analytical Sciences, 1999, 15 : 467 - 470
  • [2] Flow injection chemiluminescence determination of cephalosporins in pharmaceutical preparations using tris (2,2′-bipyridyl) ruthenium (II)-potassium permanganate system
    Thongpoon, C
    Liawruangrath, B
    Liawruangrath, S
    Wheatley, RA
    Townshend, A
    ANALYTICA CHIMICA ACTA, 2005, 553 (1-2) : 123 - 133
  • [3] Determination of morpholine fungicides using the tris(2,2′-bipyridine) ruthenium(II) chemiluminescence reaction
    Gonzalez, JM
    Greenway, GM
    McCreedy, T
    Qijun, S
    ANALYST, 2000, 125 (04) : 765 - 769
  • [4] Determination of uric acid by chemiluminescence measurement using tris(2,2′-bipyridine)ruthenium(II)-octylphenylpolyglycoI ether system
    Kim, YS
    Park, JH
    Choi, YS
    BULLETIN OF THE KOREAN CHEMICAL SOCIETY, 2004, 25 (08) : 1177 - 1181
  • [5] Chemiluminescence determination of sulfite in sugar and sulfur dioxide in air using tris(2,2′-bipyridyl)ruthenium(II)-permanganate system
    Meng, H
    Wu, FW
    He, ZK
    Zeng, YE
    TALANTA, 1999, 48 (03) : 571 - 577
  • [6] Flow-Injection Chemiluminescent Determination of Piroxicam Using Tris (2,2'-bipyridyl) Ruthenium(II)Potassium Permanganate System
    Yu, Fengshan
    Chen, Fang
    Zheng, Shishi
    Chen, Lanhua
    Cui, Man
    ANALYTICAL LETTERS, 2008, 41 (13) : 2412 - 2423
  • [7] Chemiluminescence detection of amino acids and related compounds using acidic potassium permanganate, manganese(IV) or tris(2,2′-bipyridine)ruthenium(III)
    Terry, Jessica M.
    Smith, Zoe M.
    McDermott, Geoffrey P.
    Waite, Rebecca J.
    Barnett, Neil W.
    Henderson, Luke C.
    Altimari, Jarrad M.
    Francis, Paul S.
    TALANTA, 2012, 99 : 1051 - 1056
  • [8] Determination of psilocin and psilocybin using flow injection analysis with acidic potassium permanganate and tris(2,2′-bipyridyl) ruthenium(II) chemiluminescence detection respectively
    Anastos, N
    Barnett, NW
    Lewis, SW
    Gathergood, N
    Scammells, PJ
    Sims, DN
    TALANTA, 2005, 67 (02) : 354 - 359
  • [9] ELECTROGENERATED CHEMILUMINESCENT DETERMINATION OF PYRUVATE USING TRIS(2,2'-BIPYRIDINE)RUTHENIUM(II)
    KNIGHT, AW
    GREENWAY, GM
    ANALYST, 1995, 120 (10) : 2543 - 2547
  • [10] Determination of sophoridine and related lupin alkaloids using tris(2,2′-bipyridine)ruthenium electrogenerated chemiluminescence
    Chen, X
    Yi, CQ
    Li, MJ
    Lu, X
    Li, Z
    Li, PW
    Wang, XR
    ANALYTICA CHIMICA ACTA, 2002, 466 (01) : 79 - 86