Measuring the Wall Thickness of a Trailing Arm Using Ultrasonic Measurement Model

被引:1
|
作者
Chen, Feng [1 ]
Chen, Siqi [1 ]
Zhang, Rongfan [2 ]
Shi, Yongsheng [3 ]
Gu, Liangyao [4 ]
机构
[1] Cent South Univ, Sch Traff & Transportat Engn, Changsha 410075, Peoples R China
[2] Inner Mongolia Metall Mat Res Inst China, Ningbo 315103, Peoples R China
[3] China State Railway Grp Co Ltd, Railway Infrastruct Inspect Ctr, Beijing 100081, Peoples R China
[4] Cent South Univ Forestry & Technol, Sch Mech & Elect Engn, Changsha 410004, Peoples R China
关键词
trailing arm; wall thickness; ultrasonic measurement model; Gaussian beam; curved surfaces; CORRELATION ALGORITHM;
D O I
10.3390/coatings10080773
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Trailing arms are widely used in the automobiles' suspension system, and effective detection of their wall thickness is essential to ensure their mechanical properties and to evaluate the casting process. In this work, an ultrasonic measurement model (UMM) is firstly established with consideration of the curvature and thickness of the trailing arm, then the UMM is introduced to predict the theoretical ultrasonic waveforms with different hypothetical thicknesses of the trailing arm. Next, the experimental ultrasonic waveforms are collected and matched with the predicted theoretical waveforms by using the correlation matching algorithm. The hypothetical thickness with the best match is regarded as the wall thickness of the trailing arm. Finally, an automatic ultrasonic experiment was conducted on a trailing arm with a 5-degrees of freedom (DOF) manipulator, in which the ultrasonic beam can radiate into a trailing arm at normal incidence. The results are compared with those determined by the micrometer and microscope, showing that their relative errors are controlled within 0.08 mm, which reveals the effectiveness of the present method. The method can also work for wall thickness measurements of curved components with CAD models.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Measurement uncertainty evaluation of ultrasonic wall thickness measurement
    Mihaljevic, Morana
    Markucic, Damir
    Runje, Biserka
    Keran, Zdenka
    [J]. MEASUREMENT, 2019, 137 : 179 - 188
  • [2] An appraisal of ultrasonic wall thickness measurement practices
    Lilley, JR
    [J]. CAPE '99: AGEING OF MATERIALS AND METHODS FOR THE ASSESSMENT OF LIFETIMES OF ENGINEERING PLANT, 1999, : 165 - 179
  • [3] LIMITS OF WALL-THICKNESS MEASUREMENT WITH ULTRASONIC THICKNESS GAUGES
    FRIELINGHAUS, R
    CARODISKEY, T
    [J]. MATERIALS EVALUATION, 1985, 43 (10) : 1310 - 1310
  • [4] Gas coupled ultrasonic measurement of pipeline wall thickness
    Shuttleworth, P
    Maupin, J
    Teitsma, A
    [J]. JOURNAL OF PRESSURE VESSEL TECHNOLOGY-TRANSACTIONS OF THE ASME, 2005, 127 (03): : 290 - 293
  • [5] ULTRASONIC MEASUREMENT OF WALL THICKNESS IN DIESEL CYLINDER LINER
    STRUTHERS, FW
    TRENT, HM
    [J]. JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1947, 19 (01): : 284 - 284
  • [6] AUTOMATIC ULTRASONIC WALL THICKNESS MEASUREMENT IN PIPE EXTRUSION
    ORZECHOWSKI, J
    [J]. KUNSTSTOFFE-GERMAN PLASTICS, 1987, 77 (09): : 829 - 831
  • [7] ULTRASONIC MEASUREMENT OF WALL THICKNESS IN DIESEL CYLINDER LINERS
    STRUTHERS, FW
    TRENT, HM
    [J]. JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1947, 19 (02): : 368 - 371
  • [8] ULTRASONIC MEASUREMENT OF LUMEN DIAMETER AND WALL THICKNESS OF ARTERIES
    SOKOLLU, A
    [J]. JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1962, 34 (12): : 1984 - &
  • [9] Ultrasonic measurement of thickness of carotid arterial wall using its natural longitudinal displacement
    Nagai, Yoshifumi
    Mori, Shohei
    Arakawa, Mototaka
    Kanai, Hiroshi
    [J]. JAPANESE JOURNAL OF APPLIED PHYSICS, 2023, 62 (SJ)
  • [10] A METHOD FOR THICKNESS MEASUREMENT BY MEANS OF AN ULTRASONIC PULSE THICKNESS-MEASURING DEVICE
    LOPATKO, IF
    USOSKIN, GI
    [J]. INDUSTRIAL LABORATORY, 1958, 24 (12): : 1601 - 1605