Volumetric navigators for real-time motion correction in diffusion tensor imaging

被引:48
|
作者
Alhamud, A. [1 ]
Tisdall, M. Dylan [2 ,3 ]
Hess, Aaron T.
Hasan, Khader M. [4 ]
Meintjes, Ernesta M.
van der Kouwe, Andre J. W. [2 ,3 ]
机构
[1] Univ Cape Town, Fac Hlth Sci, Dept Human Biol, MRC UCT Med Imaging Res Unit, ZA-7925 Observatory, South Africa
[2] MGH, Athinoula A Martinos Ctr Biomed Imaging, Charlestown, MA USA
[3] Harvard Univ, Sch Med, Dept Radiol, Brookline, MA USA
[4] Univ Texas Hlth Sci Ctr Houston, Dept Diagnost & Intervent Imaging, Houston, TX USA
基金
新加坡国家研究基金会;
关键词
diffusion tensor imaging (DTI); prospective motion correction; volumetric navigator; reacquisition; fractional anisotropy (FA); mean diffusivity (MD); whole brain histogram (WBH); HISTOGRAM; TISSUE; MRI; DISTORTION; ECHOES;
D O I
10.1002/mrm.23314
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Prospective motion correction methods using an optical system, diffusion-weighted prospective acquisition correction, or a free induction decay navigator have recently been applied to correct for motion in diffusion tensor imaging. These methods have some limitations and drawbacks. This article describes a novel technique using a three-dimensional-echo planar imaging navigator, of which the contrast is independent of the b-value, to perform prospective motion correction in diffusion weighted images, without having to reacquire volumes during which motion occurred, unless motion exceeded some preset thresholds. Water phantom and human brain data were acquired using the standard and navigated diffusion sequences, and the mean and whole brain histogram of the fractional anisotropy and mean diffusivity were analyzed. Our results show that adding the navigator does not influence the diffusion sequence. With head motion, the whole brain histogram-fractional anisotropy shows a shift toward lower anisotropy with a significant decrease in both the mean fractional anisotropy and the fractional anisotropy histogram peak location (P < 0.01), whereas the whole brain histogram-mean diffusivity shows a shift toward higher diffusivity with a significant increase in the mean diffusivity (P < 0.01), even after retrospective motion correction. These changes in the mean and the shape of the histograms are recovered substantially in the prospective motion corrected data acquired using the navigated sequence. Magn Reson Med, 2012. (c) 2012 Wiley Periodicals, Inc.
引用
收藏
页码:1097 / 1108
页数:12
相关论文
共 50 条
  • [1] Real-Time Optical Motion Correction for Diffusion Tensor Imaging
    Aksoy, Murat
    Forman, Christoph
    Straka, Matus
    Skare, Stefan
    Holdsworth, Samantha
    Hornegger, Joachim
    Bammer, Roland
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2011, 66 (02) : 366 - 378
  • [2] Real-time motion correction using octant navigators
    van der Kouwe, A
    Dale, A
    [J]. NEUROIMAGE, 2001, 13 (06) : S48 - S48
  • [3] Spiral MR imaging for diffusion imaging with real-time motion monitoring and motion correction
    Tsukamoto, T
    King, KF
    Foo, TK
    Yoshitome, E
    [J]. RADIOLOGY, 1996, 201 : 146 - 146
  • [4] Real-time simultaneous shim and motion measurement and correction in glycoCEST MRI using double volumetric navigators (DvNavs)
    Simegn, Gizeaddis L.
    Van der Kouwe, Andre J. W.
    Robertson, Frances C.
    Meintjes, Ernesta M.
    Alhamud, Ali
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2019, 81 (04) : 2600 - 2613
  • [5] Real-time motion and retrospective coil sensitivity correction for CEST using volumetric navigators (vNavs) at 7T
    Poblador Rodriguez, Esau
    Moser, Philipp
    Auno, Sami
    Eckstein, Korbinian
    Dymerska, Barbara
    van der Kouwe, Andre
    Gruber, Stephan
    Trattnig, Siegfried
    Bogner, Wolfgang
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2021, 85 (04) : 1909 - 1923
  • [6] Real-time measurement and correction of both B0 changes and subject motion in diffusion tensor imaging using a double volumetric navigated (DvNav) sequence
    Alhamud, A.
    Taylor, Paul A.
    van der Kouwe, Andre J. W.
    Meintjes, Ernesta M.
    [J]. NEUROIMAGE, 2016, 126 : 60 - 71
  • [7] Real-time rigid body motion correction and shimming using cloverleaf navigators
    van der Kouwe, Andre J. W.
    Benner, Thomas
    Dale, Anders M.
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2006, 56 (05) : 1019 - 1032
  • [8] Real-time motion and B0 correction for localized adiabatic selective refocusing (LASER) MRSI using echo planar imaging volumetric navigators
    Hess, Aaron T.
    Andronesi, Ovidiu C.
    Tisdall, M. Dylan
    Sorensen, A. Gregory
    van der Kouwe, Andre J. W.
    Meintjes, Ernesta M.
    [J]. NMR IN BIOMEDICINE, 2012, 25 (02) : 347 - 358
  • [9] Optimal real-time estimation in diffusion tensor imaging
    Casaseca-de-la-Higuera, Pablo
    Tristan-Vega, Antonio
    Aja-Fernandez, Santiago
    Alberola-Lopez, Carlos
    Westin, Carl-Fredrik
    San Jose Estepar, Raul
    [J]. MAGNETIC RESONANCE IMAGING, 2012, 30 (04) : 506 - 517
  • [10] Real-Time Motion and B0 Corrected Single Voxel Spectroscopy Using Volumetric Navigators
    Hess, Aaron T.
    Tisdall, M. Dylan
    Andronesi, Ovidiu C.
    Meintjes, Ernesta M.
    van der Kouwe, Andre J. W.
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2011, 66 (02) : 314 - 323