Reliability and validity of the Turkish version of the satisfaction module of the Orthotics and Prosthetics Users' Survey

被引:3
|
作者
Demirdel, Senem [1 ]
Ulas, Kardem [2 ]
Celik, Seher Erol [3 ]
Karahan, Sevilay [4 ]
Topuz, Semra [5 ]
机构
[1] Univ Hlth Sci, Dept Physiotherapy & Rehabil, Ankara, Turkey
[2] Final Univ, Dept Physiotherapy & Rehabil, Girne, Cyprus
[3] Ankara Univ, Dept Physiotherapy, Ankara, Turkey
[4] Hacettepe Univ, Dept Biostat, Ankara, Turkey
[5] Hacettepe Univ, Fac Phys Therapy & Rehabil, Ankara, Turkey
关键词
patient satisfaction; surveys; outcome assessment; rehabilitation; orthotic devices; prostheses; CLIENT SATISFACTION; OUTCOME MEASURES; DEVICE MODULE; HEALTH; VALIDATION; AMPUTATION; SAMPLE; SET;
D O I
10.1097/PXR.0000000000000067
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Evaluation of prosthesis and orthosis (P&O) devices and service satisfaction in patients using P&O are important to understand the patient perspective and improve the quality of devices and the services. Objective: The aim of this study was to translate the original Orthotics and Prosthetics Users' Survey (OPUS) satisfaction module into Turkish and examine its psychometric properties in lower limb P&O users. Study Design: Cross-sectional study. Methods: The Turkish versions of the OPUS-Client Satisfaction with Device (CSD) and Service (CSS) modules were applied to 157 individuals using a lower limb prosthesis or orthosis. The retest of the survey was applied 5-7 days later. Intraclass correlation coefficient was used to determine test-retest reliability, and Cronbach alpha was used to determine internal consistency. Criterion validity was evaluated using the Nottingham Health Profile. Exploratory factor analysis was used to examine the factor structure of the Turkish version of the OPUS satisfaction module. Results: The test-retest correlation (intraclass correlation coefficient 5 0.92 for CSD and 0.91 for CSS) and internal consistency (Cronbach's alpha 5 0.84 for CSD and 0.95 for CSS) were high. A statistically significant correlation was found between the OPUS CSD and CSS modules and the Nottingham Health Profile (r520.325 for CSD module, r520.381 for CSS module, P, 0.001). The factor analysis revealed one-factor structure for both modules. Conclusions: This study demonstrated the reliability and validity of the Turkish version of the OPUS satisfaction module, and it provides a useful starting point for future studies on this survey.
引用
收藏
页码:170 / 174
页数:5
相关论文
共 50 条
  • [1] The Persian version of satisfaction assessment module of Orthotics and Prosthetics Users' Survey
    Hadadi, Mohammad
    Ghoseiri, Kamiar
    Fardipour, Shima
    Kashani, Reza Vahab
    Asadi, Farnoosh
    Asghari, Azizeh
    [J]. DISABILITY AND HEALTH JOURNAL, 2016, 9 (01) : 90 - 99
  • [2] Validation of the Arabic version of the client satisfaction with device module of the "orthotics and prosthetics users" survey
    Bakhsh, Hadeel
    Franchignoni, Franco
    Bravini, Elisabetta
    Ferriero, Giorgio
    Giordano, Andrea
    Foti, Calogero
    [J]. ANNALS OF SAUDI MEDICINE, 2014, 34 (04) : 320 - 327
  • [3] Validation of the Italian version of the Client Satisfaction with Device module of the Orthotics and Prosthetics Users' Survey
    Bravini, Elisabetta
    Franchignoni, Franco
    Ferriero, Giorgio
    Giordano, Andrea
    Bakhsh, Hadeel
    Sartorio, Francesco
    Vercelli, Stefano
    [J]. DISABILITY AND HEALTH JOURNAL, 2014, 7 (04) : 442 - 447
  • [4] Validity evidence for a modified version of the Orthotics and Prosthetics Users' Survey
    Jarl, Gustav M.
    Heinemann, Allen W.
    Hermansson, Liselotte M. Norling
    [J]. DISABILITY AND REHABILITATION-ASSISTIVE TECHNOLOGY, 2012, 7 (06) : 469 - 478
  • [5] Validity, reliability, and Rasch analysis of the orthotics and prosthetics users' survey: Turkish version of the lower-extremity functional status
    Soyer, Kardem
    Demirdel, Senem
    Celik, Seher Erol
    Topuz, Semra
    Karahan, Sevilay
    [J]. PROSTHETICS AND ORTHOTICS INTERNATIONAL, 2023, 47 (03) : 307 - 312
  • [6] Test-retest reliability of the Swedish version of the Orthotics and Prosthetics Users' Survey
    Jarl, Gustav
    Holmefur, Marie
    Hermansson, Liselotte M. N.
    [J]. PROSTHETICS AND ORTHOTICS INTERNATIONAL, 2014, 38 (01) : 21 - 26
  • [7] Psychometric properties of the Client Satisfaction with Device module of the Orthotics and Prosthetics Users' Survey (OPUS): a scoping review
    Sorrentino, Gregorio
    Vercelli, Stefano
    Salgovic, Ludovit
    Ronconi, Gianpaolo
    Bakhsh, Hadeel R.
    Ferriero, Giorgio
    [J]. INTERNATIONAL JOURNAL OF REHABILITATION RESEARCH, 2021, 44 (03) : 193 - 199
  • [8] Translation and linguistic validation of the Swedish version of Orthotics and Prosthetics Users' Survey
    Jarl, Gustav Magnus
    Hermansson, Liselotte Maria Norling
    [J]. PROSTHETICS AND ORTHOTICS INTERNATIONAL, 2009, 33 (04) : 329 - 338
  • [9] Translation and validation of the Malay version of modified orthotics and prosthetics users' survey
    Hashim, Natiara Mohamad
    Che Daud, Ahmad Zamir
    Ibrahim, Al Hafiz
    Ab Majid, Mohammad Hafidzi
    Ghazali, Mohd Nasrul Mohd
    Razak, Muhammad Mahdi Abdul
    Rusli, Muhamad Rahimi Mohd
    [J]. PROSTHETICS AND ORTHOTICS INTERNATIONAL, 2024, 48 (01) : 89 - 99
  • [10] The validity and reliability of Turkish version of the Duke anticoagulation satisfaction scale
    Yildirim, Julide Gulizar
    Temel, Ayla Bayik
    [J]. TURK GOGUS KALP DAMAR CERRAHISI DERGISI-TURKISH JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2014, 22 (04): : 761 - 772