Caustic corrosion in a boiler waterside tube: Root cause and mechanism

被引:45
|
作者
Daneshvar-Fatah, Farhad [1 ]
Mostafaei, Amir [1 ]
Hosseinzadeh-Taghani, Reza [1 ]
Nasirpouri, Farzad [1 ]
机构
[1] Sahand Univ Technol, Dept Mat Engn, Res Ctr Adv Mat & Minerals Proc, Lab Failure Anal, Tabriz, Iran
关键词
Failure analysis; Metallurgical examination; Boiler tube; Caustic corrosion; Low alloy steel; FAILURE ANALYSIS; CRACKING; HEATER;
D O I
10.1016/j.engfailanal.2012.09.010
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
We report a failure occurred in a boiler tube of low alloy steel, SA-210 Grade A-1. A severe thickness reduction was detected in a boiler tube during periodic investigations. Two identical parallel grooves along the horizontal tube were observed. The inner surface of the tube consisted of three distinct parts: (1) dark gray scale under the grooves, (2) hemi-elliptical grooves, and (3) brown porous scale above the grooves. Microscopic investigations and microhardness tests revealed that the microstructure and properties of the base metal is intact along the tube. Moreover, some needle shape crystals which represented Na2FeO2 and NaFeO2 compounds were observed in SEM images taken from the groove scale. An excessive amount of Na and Cu was detected by EDS in the groove. The XRD results confirmed the presence NaFeO2 which is the main product of caustic corrosion. Therefore, it was concluded that the evaporation at the waterline of the partially filled tube leaded to locally caustic concentration which dissolves the protective magnetite layer and subsequently attacked the bare metal. (C) 2012 Elsevier Ltd. All rights reserved.
引用
收藏
页码:69 / 77
页数:9
相关论文
共 50 条
  • [1] A LABORATORY SIMULATION OF WATERSIDE BOILER CORROSION
    POTTER, EC
    MANN, GMW
    [J]. CHEMISTRY & INDUSTRY, 1963, (44) : 1768 - 1768
  • [2] Root cause failure investigation of a boiler waterwall tube employed in a 325 MW thermal power plant: Caustic corrosion phenomenon and its effects
    Soltanloo, Mostafa
    Babaee, Mohammad Hossein
    Yeganeh, Sayyed Ehsan Hosseini
    Shafiei, Ali
    Akbari, Amir Hossein
    [J]. ENGINEERING FAILURE ANALYSIS, 2022, 133
  • [3] Bulging rupture and caustic corrosion of a boiler tube in a thermal power plant
    Kim, Y-S
    Kim, W-C
    Kim, J-G
    [J]. ENGINEERING FAILURE ANALYSIS, 2019, 104 : 560 - 567
  • [4] WATERSIDE CORROSION OF POWER STATION BOILER TUBES
    MASTERSON, HG
    CASTLE, JE
    MANN, GMW
    [J]. CHEMISTRY & INDUSTRY, 1969, (36) : 1261 - +
  • [5] Root cause analysis of stress corrosion at tube-to-tubesheet joints of a waste heat boiler
    Sui Rongjuan
    Wang Weiqiang
    Liu Yan
    Li Dong
    Li Wei
    [J]. ENGINEERING FAILURE ANALYSIS, 2014, 45 : 398 - 405
  • [6] Failure Investigation of Boiler Tube: A Root Cause Analysis
    Ghosh, M.
    [J]. JOURNAL OF FAILURE ANALYSIS AND PREVENTION, 2023, 23 (03) : 1222 - 1231
  • [7] Failure Investigation of Boiler Tube: A Root Cause Analysis
    M. Ghosh
    [J]. Journal of Failure Analysis and Prevention, 2023, 23 : 1222 - 1231
  • [8] Boiler tube failure root cause analysis advisory system
    Gonzalez, H
    Chang, PS
    [J]. PROCEEDINGS OF THE TWENTY-NINTH SOUTHEASTERN SYMPOSIUM ON SYSTEM THEORY, 1997, : 201 - 205
  • [9] Caustic corrosion failure of back wall riser tube in a high-pressure boiler
    Mobin M.
    Malik A.U.
    [J]. Journal of Failure Analysis and Prevention, 2011, 11 (4) : 357 - 362
  • [10] Waterside corrosion of condenser's tube and precautions
    Li, Hongtao
    Yu, Chuanping
    Cui, Jianguo
    [J]. Qilunji Jishu/Turbine Technology, 2000, 42 (04): : 242 - 245