Rupture of mitral valve annulus after mitral balloon valvotomy: A case report

被引:0
|
作者
Ressia, L
Depieri, G
Grande, AM
Vigano, M
机构
来源
JOURNAL OF HEART VALVE DISEASE | 1997年 / 6卷 / 01期
关键词
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
We report the case of a 51-year-old woman who underwent percutaneous mitral valvotomy using single balloon technique for restenosis after a previous surgical closed commissurotomy. After the procedure, she presented with severe mitral regurgitation and was referred to our center for mitral valve replacement. At surgery, the underlying cause of the mitral regurgitation was shown to be a tear at the commissural site which extended into the annulus. The mitral valve was successfully replaced and the postoperative course was uneventful. One year later the patient is in good clinical condition.
引用
收藏
页码:74 / 76
页数:3
相关论文
共 50 条
  • [1] Balloon Rupture During Balloon Mitral Valvotomy
    Gupta, Preeti
    Gupta, Anunay
    Agstam, Sourabh
    Bansal, Sandeep
    JOURNAL OF INVASIVE CARDIOLOGY, 2021, 33 (11): : E916 - E916
  • [2] Mitral valve endocarditis following balloon mitral valvotomy
    Sood, P
    Dogra, V
    Mishra, B
    Mandal, A
    Banerjee, A
    SCANDINAVIAN JOURNAL OF INFECTIOUS DISEASES, 2001, 33 (04) : 312 - 313
  • [3] Repeat Percutaneous Balloon Mitral Valvotomy vs Mitral Valve Replacement in Patients With Restenosis After Previous Balloon Mitral Valvotomy and Unfavorable Valve Characteristics
    Aslanabadi, Naser
    Golmohammadi, Ali
    Sohrabi, Bahram
    Kazemi, Babak
    CLINICAL CARDIOLOGY, 2011, 34 (06) : 401 - 406
  • [4] Response to Repeat Percutaneous Balloon Mitral Valvotomy vs. Mitral Valve Replacement in Patients With Restenosis After Previous Balloon Mitral Valvotomy and Unfavorable Valve Characteristics
    Sivadasanpillai, Harikrishnan
    Nair, Krishnakumar
    CLINICAL CARDIOLOGY, 2012, 35 (05) : 317 - 318
  • [5] Does the mitral valve recoil after percutaneous balloon valvotomy?
    Karthikeyan, Ganesan
    Yadav, Rakesh
    Narang, Rajiv
    Bhargava, Balram
    CARDIOVASCULAR REVASCULARIZATION MEDICINE, 2011, 12 (03) : 147 - 151
  • [6] Response to Repeat Percutaneous Balloon Mitral Valvotomy vs. Mitral Valve Replacement in Patients with Restenosis after Previous Balloon Mitral Valvotomy and Unfavorable Valve Characteristics Reply
    Aslanabadi, Naser
    Kazemi, Babak
    CLINICAL CARDIOLOGY, 2012, 35 (05) : 318 - 318
  • [7] Percutaneous balloon mitral valvotomy as a bridge to elective mitral valve replacement
    Chow, WH
    Chow, TC
    CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1998, 45 (01): : 102 - 102
  • [8] Mitral Valve Replacement for Bulky, Calcified Mitral Annulus: A Case Report
    Nakata, Yusuke
    Miyamoto, Kazuyuki
    JOURNAL OF CHEST SURGERY, 2024, 57 (05): : 496 - 499
  • [9] Comparison of long-term outcome after mitral valve replacement or repeated balloon mitral valvotomy in patients with restenosis after previous balloon valvotomy
    Kim, Jin-Bae
    Ha, Jong-Won
    Kim, Jung-Sun
    Shim, Won-Heum
    Kang, Seok-Min
    Ko, Young-Guk
    Choi, Donghoon
    Jang, Yangsoo
    Chung, Namsik
    Cho, Seung-Yun
    Kim, Sung-Soon
    AMERICAN JOURNAL OF CARDIOLOGY, 2007, 99 (11): : 1571 - 1574
  • [10] BALLOON MITRAL VALVOTOMY IN A PREGNANT PATIENT - A CASE-REPORT
    RACHOR, S
    KNEISSEL, GD
    FACH, A
    SCHRADER, R
    ZEITSCHRIFT FUR KARDIOLOGIE, 1994, 83 (03): : 238 - 241