Energy performance analysis of an office building in three climate zones

被引:29
|
作者
Jung, Nusrat [1 ,2 ]
Paiho, Satu [2 ]
Shemeikka, Jari [2 ]
Lahdelma, Risto [1 ,3 ]
Airaksinen, Miimu [2 ]
机构
[1] Aalto Univ, Sch Engn, Dept Mech Engn, Espoo, Finland
[2] VTT Tech Res Ctr Finland, Espoo, Finland
[3] Aalto Univ, Sch Sci, Dept Math & Syst Anal, Espoo, Finland
基金
芬兰科学院;
关键词
Energy performance; Energy efficiency; nZEB; Multi zone; Office buildings; Dynamic simulations; Helsinki; London; Bucharest; Radiant ceiling panels; Radiant floor panels; IDA ICE; ZERO; CARBON; EFFICIENCY;
D O I
10.1016/j.enbuild.2017.10.030
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Most of the studies encompassing dynamic simulations of multi-storey buildings account only for a few selected zones, to simplify, decrease simulation run-time and to reduce the complexity of the 'to be simulated' model. This conventional method neglects the opportunity to see the interaction between different zones as it relates to whole building performance. This paper presents fifteen individual cases of dynamic simulations of a six-storey office building with 160 zones. The energy performance analysis was conducted for three climate zones including Helsinki in Finland, London in the United Kingdom and Bucharest in Romania. For each location, the following three cases were simulated: (i) building as usual simulated according to valid national building codes; (ii) Energy-efficient (EE) case with selected necessary parameters enhanced to reduce total delivered energy demand; and (iii) nZEB case representing partial enhancement of the EE case based on the parametric analysis. The results of nZEB indicate that for Helsinki, it is possible to reduce the space-heating load by 86%, electricity consumed by lighting, appliance, and HVAC by 32%. For London, the heating load is reduced by 95%, cooling load is slightly increased, and electricity demand is decreased by 33%. For Bucharest, 92% of energy in heating can be saved, cooling energy demand was reduced by 60% and electricity consumption by 34%. Based on the nZEB cases for each location, alternative heating and cooling choices of a radiant floor panel system and radiant ceiling panel system were explored. There are small differences in absolute consumption demand for heating, cooling, and electricity for three cases in each location. The specific energy/m(2) for heating remained nearly the same in all systems for all three cases in each location. Alternative choices for heating and cooling by using Radiant Ceiling Panel (RCP) and Radiant Floor Panel (RFP) were investigated for all final nZEB cases. Marginal difference in heating energy required for space heating can be seen for London nZEB IHC and London nZEB RCP of 0.8 kWh/m(2)/year and for Bucharest nZEB IHC and Bucharest nZEB RCP case of 1.3 kWh/m(2)/year. RFP has the availability of large surface area for heat exchange and can provide heating at a low temperature and cooling at high temperature, but requires supporting air based cooling during the humid season. For RCP, the limited temperature exchange surface may increase the airflow rate, but supplies it at a lower temperature for the same load. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:1023 / 1035
页数:13
相关论文
共 50 条
  • [1] Analysis of the Thermal and Cooling Energy Performance of the Perimeter Zones in an Office Building
    Lim, Taesub
    Yim, Woong-Seog
    Kim, Daeung-Danny
    [J]. BUILDINGS, 2022, 12 (02)
  • [2] Evaluation on energy and thermal performance for office building envelope in different climate zones of China
    Yu, Jinghua
    Tian, Liwei
    Xu, Xinhua
    Wang, Jinbo
    [J]. ENERGY AND BUILDINGS, 2015, 86 : 626 - 639
  • [3] Energy performance of building envelopes in different climate zones in China
    Yang, Liu
    Lam, Joseph C.
    Tsang, C. L.
    [J]. APPLIED ENERGY, 2008, 85 (09) : 800 - 817
  • [4] Energy Consumption Performance Considering Climate Change in Office Building
    Zhao, Deyin
    Fan, Hongwu
    Pan, Li
    Xu, Qiang
    Zhang, Xu
    [J]. 10TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATION AND AIR CONDITIONING, ISHVAC2017, 2017, 205 : 3448 - 3455
  • [5] Evaluation of Building Energy and Daylight Performance of Electrochromic Glazing for Optimal Control in Three Different Climate Zones
    Oh, Myunghwan
    Jang, Minsu
    Moon, Jaesik
    Roh, Seungjun
    [J]. SUSTAINABILITY, 2019, 11 (01):
  • [6] Daylight Analysis of a Typical Low Rise Office Building for Different Climate Zones of India
    Mathew, Mobi
    Kini, Savitha G.
    [J]. 2016 INTERNATIONAL CONFERENCE ON ENERGY EFFICIENT TECHNOLOGIES FOR SUSTAINABILITY (ICEETS), 2016, : 549 - 553
  • [7] Comprehensive analysis of energy and visual performance of building-integrated photovoltaics in all ASHRAE climate zones
    Hossei, Hamideh
    Kim, Kyoung Hee
    [J]. Energy and Buildings, 2024, 317
  • [8] Energy Conservation for an Office Building in a Hot Climate
    Dalal, Hari S.
    [J]. THIRD INTERNATIONAL CONFERENCE ON EFFICIENT BUILDING DESIGN - MATERIALS AND HVAC EQUIPMENT TECHNOLOGIES, 2018, : 240 - 245
  • [9] The effects of shading devices on office building energy performance in Mediterranean climate regions
    Koc, Sena Goknur
    Kalfa, Sibel Macka
    [J]. JOURNAL OF BUILDING ENGINEERING, 2021, 44
  • [10] The impact of climate change on an office building in Portugal: Measures for a higher energy performance
    Fernandes, Marco S.
    Coutinho, Beatriz
    Rodrigues, Eugenio
    [J]. JOURNAL OF CLEANER PRODUCTION, 2024, 445