Feature-based multibody rigid registration of CT and ultrasound images of lumbar spine

被引:23
|
作者
Rasoulian, Abtin [1 ]
Abolmaesumi, Purang [1 ]
Mousavi, Parvin [2 ]
机构
[1] Univ British Columbia, Vancouver, BC V6T 1Z4, Canada
[2] Queens Univ, Sch Comp, Kingston, ON K7L 3N6, Canada
基金
加拿大自然科学与工程研究理事会; 加拿大健康研究院;
关键词
ultrasound; CT; multibody registration; spinal injections; ACCURACY; CALIBRATION; INJECTIONS; MODELS;
D O I
10.1118/1.4711753
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Fusion of intraprocedure ultrasound and preprocedure CT data is proposed for guidance in percutaneous spinal injections, a common procedure for pain management. CT scan of the lumbar spine is usually collected in a supine position, whereas spinal injections are performed in prone or sitting positions. This leads to a difference in the spine curvature between CT and ultrasound images; as such, a single-body rigid registration approach cannot be used for the whole lumbar vertebrae. Methods: To compensate for the difference in the spinal curvature between the two imaging modalities, a multibody rigid registration algorithm is presented. The approach utilizes a point-based registration technique based on the unscented Kalman filter (UKF), taking as input segmented vertebrae surfaces in both CT and ultrasound data. Ultrasound images are automatically segmented using a dynamic programming method, while the CT images are semiautomatically segmented using thresholding. The registration approach is designed to simultaneously align individual groups of points segmented from each vertebra in the two imaging modalities. A biomechanical model is developed to constrain the vertebrae transformation parameters during the registration and to ensure convergence. Results: The proposed methodology is evaluated on human spine phantoms and a sheep cadaver. Registrations on phantom data have a mean target registration error (TRE) of 1.99 mm in the region of interest and converged in 87% of cases. Registrations on sheep cadaver have a mean target registration error of 2.2 mm and converged in 82% of cases. Conclusions: The proposed technique can robustly and simultaneously register several vertebrae extracted from CT images to the ultrasound volumes. The registration error below 2.2 mm is sufficient for most spinal injections. (C) 2012 American Association of Physicists in Medicine. [http://dx.doi.org/10.1118/1.4711753]
引用
收藏
页码:3154 / 3166
页数:13
相关论文
共 50 条
  • [1] Group-wise Feature-based Registration of CT and Ultrasound Images of Spine
    Rasoulian, Abtin
    Mousavi, Parvin
    Moghari, Mehdi Hedjazi
    Foroughi, Pezhman
    Abolmaesumi, Purang
    MEDICAL IMAGING 2010: VISUALIZATION, IMAGE-GUIDED PROCEDURES, AND MODELING, 2010, 7625
  • [2] FEATURE-BASED REGISTRATION OF RETINAL IMAGES
    PELI, E
    AUGLIERE, RA
    TIMBERLAKE, GT
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 1987, 6 (03) : 272 - 278
  • [3] FEATURE-BASED PIECEWISE RIGID REGISTRATION IN 2-D MEDICAL IMAGES
    Smeets, Dirk
    Keustermans, Johannes
    Hermans, Jeroen
    Vandermeulen, Dirk
    Suetens, Paul
    2012 9TH IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING (ISBI), 2012, : 696 - 699
  • [4] Feature-Based Non-Rigid Registration of Serial Section Images by Blending Rigid Transformations
    Kajihara, Takehiro
    Funatomi, Takuya
    Kubo, Hiroyuki
    Aoto, Takahito
    Makishima, Haruyuki
    Yamada, Shigehito
    Mukaigawa, Yasuhiro
    PROCEEDINGS 2017 4TH IAPR ASIAN CONFERENCE ON PATTERN RECOGNITION (ACPR), 2017, : 858 - 863
  • [5] Feature-based deformable registration of brain images
    Shi, YH
    Qi, FH
    17TH IEEE SYMPOSIUM ON COMPUTER-BASED MEDICAL SYSTEMS, PROCEEDINGS, 2004, : 553 - 557
  • [6] FEATURE-BASED REGISTRATION OF RETINAL IMAGES.
    Peli, Eli
    Augliere, Reed A.
    Timberlake, George T.
    IEEE Transactions on Medical Imaging, 1987, MI-6 (03) : 272 - 278
  • [7] An Efficient Feature-based Non-rigid Registration of Multiphase Liver CT Images using Matching Region Partition
    Cao, Ying
    Jiang, Hui-yan
    Qian, Ting-jun
    Zhu, Zhi-liang
    Wang, Bei-lei
    Mao, Ke-ming
    Liu, Hong-juan
    ICIEA 2010: PROCEEDINGS OF THE 5TH IEEE CONFERENCE ON INDUSTRIAL ELECTRONICS AND APPLICATIONS, VOL 3, 2010, : 505 - 509
  • [8] SIFT and shape context for feature-based nonlinear registration of thoracic CT images
    Urschler, Martin
    Bauer, Joachim
    Ditt, Hendrik
    Bischof, Horst
    COMPUTER VISION APPROACHES TO MEDICAL IMAGE ANALYSIS, 2006, 4241 : 73 - 84
  • [9] Biomechanically constrained groupwise ultrasound to CT registration of the lumbar spine
    Gill, Sean
    Abolmaesumi, Purang
    Fichtinger, Gabor
    Boisvert, Jonathan
    Pichora, David
    Borshneck, Dan
    Mousavi, Parvin
    MEDICAL IMAGE ANALYSIS, 2012, 16 (03) : 662 - 674
  • [10] Hierarchical CT to Ultrasound Registration of the Lumbar Spine: A Comparison with Other Registration Methods
    Koo, Terry K.
    Kwok, Wingchi Edmund
    ANNALS OF BIOMEDICAL ENGINEERING, 2016, 44 (10) : 2887 - 2900