Integrated two-step gene synthesis in a microfluidic device

被引:32
|
作者
Huang, Mo Chao [1 ]
Ye, Hongye [1 ]
Kuan, Yoke Kong [1 ]
Li, Mo-Huang [1 ]
Ying, Jackie Y. [1 ]
机构
[1] Inst Bioengn & Nanotechnol, Singapore 138669, Singapore
关键词
DNA AMPLIFICATION; CHEMICAL-SYNTHESIS; HIGH-FIDELITY; PCR; PROTEIN; STEP; CHIP; FABRICATION; POLYMERASE; EXTRACTION;
D O I
10.1039/b807688j
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Herein we present an integrated microfluidic device capable of performing two-step gene synthesis to assemble a pool of oligonucleotides into genes with the desired coding sequence. The device comprised of two polymerase chain reactions (PCRs), temperature-controlled hydrogel valves, electromagnetic micromixer, shuttle micromixer, volume meters, and magnetic beads based solid-phase PCR purification, fabricated using a fast prototyping method without lithography process. The fabricated device is combined with a miniaturized thermal cycler to perform gene synthesis. Oligonucleotides were first assembled into genes by polymerase chain assembly(PCA), and the full-length gene was amplified by a second PCR. The synthesized gene was further separated from the PCR reaction mixture by the solid-phase PCR purification. We have successfully used this device to synthesize a green fluorescent protein fragment (GFPuv) (760 bp), and obtained comparable synthesis yield and error rate with experiments conducted in a PCR tube within a commercial thermal cycler. The resulting error rate determined by DNA sequencing was 1 per 250 bp. To our knowledge, this is the first microfluidic device demonstrating integrated two-step gene synthesis.
引用
收藏
页码:276 / 285
页数:10
相关论文
共 50 条
  • [1] Two-step total gene synthesis method
    Young, L
    Dong, QH
    NUCLEIC ACIDS RESEARCH, 2004, 32 (07) : e59
  • [2] Improvement on the two-step total gene synthesis method
    Gao, Chaohui
    Zhao, Xiangyang
    Meng, Qingfan
    Lu, Jin
    Wang, Xi
    Teng, Lirong
    JOURNAL OF BIOTECHNOLOGY, 2008, 136 : S628 - S628
  • [3] A two-step synthesis of terbinafine
    Alami, M
    Ferri, F
    Gaslain, Y
    TETRAHEDRON LETTERS, 1996, 37 (01) : 57 - 58
  • [4] A two-step synthesis of terbinafine
    Tetrahedron Lett, 1 (57):
  • [5] Study on the behavior of an integrated two-stage reactor for two-step methanol synthesis
    Linghu, WS
    Liu, ZY
    Zhong, B
    Li, YW
    PETROLEUM SCIENCE AND TECHNOLOGY, 2001, 19 (7-8) : 825 - 836
  • [6] Parallel gene synthesis in a microfluidic device
    Kong, David S.
    Carr, Peter A.
    Chen, Lu
    Zhang, Shuguang
    Jacobson, Joseph M.
    NUCLEIC ACIDS RESEARCH, 2007, 35 (08)
  • [7] A concise two-step synthesis of thalidomide
    Muller, GW
    Konnecke, WE
    Smith, AM
    Khetani, VD
    ORGANIC PROCESS RESEARCH & DEVELOPMENT, 1999, 3 (02) : 139 - 140
  • [8] Application of Microfluidic Devices for Automated Two-Step Radiolabeling of Antibodies
    Jinda, Hiroki
    Watanabe, Hiroyuki
    Nakashima, Kazuma
    Ono, Masahiro
    JOURNAL OF LABELLED COMPOUNDS & RADIOPHARMACEUTICALS, 2024, 67 (10): : 341 - 348
  • [9] A Two-Step Process for the Synthesis of Hydroxytyrosol
    Ziosi, Paolo
    Paolucci, Claudio
    Santarelli, Francesco
    Tabanelli, Tommaso
    Passeri, Sauro
    Cavani, Fabrizio
    Righi, Paolo
    CHEMSUSCHEM, 2018, 11 (13) : 2202 - 2210
  • [10] The two-step mechanochemical synthesis of porphyrins
    Shy, Hannah
    Mackin, Paula
    Orvieto, Andrea S.
    Gharbharan, Deepa
    Peterson, Geneva R.
    Bampos, Nick
    Hamilton, Tamara D.
    FARADAY DISCUSSIONS, 2014, 170 : 59 - 69