Rotational Stability of a Single-Piece Hydrophobic Acrylic Intraocular Lens During Removal of Ophthalmic Viscosurgical Devices

被引:8
|
作者
Hyon, Joon Young [1 ,2 ]
Yeo, Hwan Eok [3 ]
机构
[1] Seoul Natl Univ, Coll Med, Dept Ophthalmol, Seoul, South Korea
[2] Seoul Natl Univ, Dept Ophthalmol, Bundang Hosp, Songnam 463707, Gyeonggi, South Korea
[3] Kims Eye Hosp, Dept Ophthalmol, Seoul, South Korea
关键词
CATARACT-SURGERY; VISCOELASTIC SUBSTANCES; ASTIGMATISM CORRECTION; CORNEAL TUNNEL; INCISION; EYES; KERATOTOMY; BIOMETRY;
D O I
10.1016/j.ajo.2009.08.014
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To compare the effect of cohesive and dispersive ophthalmic viscosurgical device (OVD) on intraoperative rotational stability of the intraocular lens (IOL) with single-piece hydrophobic acrylate platform. DESIGN: Prospective, comparative study. METHODS: This institutional clinical study included 60 eyes of 60 patients who underwent phacoemulsifcation. The patients were equally divided into cohesive OVD (Healon GV; Abbott Medical Optics, Abbott Park, Illinois, USA) group and dispersive OVD (Viscoat; Alcon Laboratories, Fort Worth, Texas, USA) group. Image analysis from the captured digital image was used to measure intraoperative rotation of single-piece hydrophobic acrylate IOL (SA60AT or SA60NT) during OVD removal. RESULTS: Mean intraoperative rotation was 7.42 degrees +/- 4.16 (standard deviation) in dispersive OVD group and 13.08 degrees +/- 5.25 (standard deviation) in cohesive OVD group (P < .001). Twenty-one cases (70%) maintained the alignment within 10 degrees during removal of OVD with dispersive OVD, while only 9 cases (30%) did so with cohesive OVD (P = .005). Counterclockwise rotation was observed in 33% of the all cases. CONCLUSIONS: This study showed that a significant amount of IOL rotation occurred during OVD removal. Intraoperative rotational stability of IOL was greater with Viscoat than with Healon GV. (Am J Ophthalmol 2010; 149:253-257. (C) 2010 by Elsevier Inc. All rights reserved.)
引用
收藏
页码:253 / 257
页数:5
相关论文
共 50 条
  • [1] Rotational stability of a single-piece toric acrylic intraocular lens
    Koshy, John J.
    Nishi, Yutaro
    Hirnschall, Nino
    Crnej, Alja
    Gangwani, Vinod
    Maurino, Vincenzo
    Findl, Oliver
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2010, 36 (10): : 1665 - 1670
  • [2] True rotational stability of a single-piece hydrophobic intraocular lens
    Schartmueller, Daniel
    Schriefl, Sabine
    Schwarzenbacher, Luca
    Leydolt, Christina
    Menapace, Rupert
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2019, 103 (02) : 186 - 190
  • [3] Rotational Stability of a Single-Piece Toric Acrylic Intraocular Lens: A Pilot Study
    Hirnschall, Nino
    Maedel, Sophie
    Weber, Maria
    Findl, Oliver
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2014, 157 (02) : 405 - 411
  • [4] Comparison of stability between a modular intraocular lens system and a single-piece hydrophobic acrylic intraocular lens
    SooHoo, Jeffrey R.
    Lane, Stephen S.
    Cionni, Robert J.
    Berdahl, John P.
    Sussman, Glenn R.
    Kahook, Malik Y.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2016, 42 (12): : 1821 - 1825
  • [5] Rotational stability and capsular bag performance of a hydrophobic acrylic open-loop single-piece intraocular lens
    Ullrich, Marlies
    Fisus, Andreea D.
    Palkovits, Stefan
    Hienert, Julius
    Hirnschall, Nino
    Findl, Oliver
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2024, 34 (06) : 1899 - 1908
  • [6] Rotational stability of a single-piece hydrophobic acrylic intraocular lens:: New method for high-precision rotation control
    Weinand, Frank
    Jung, Annette
    Stein, Alexandra
    Pfuetzner, Andreas
    Becker, Ralph
    Pavlovic, Sima
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2007, 33 (05): : 800 - 803
  • [7] Rotational stability of two single-piece toric acrylic intraocular lenses
    Steinwender, Gernot
    Ardjomand, Navid
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (15)
  • [8] Glistenings in the single-piece, hydrophobic, acrylic intraocular lenses
    Waite, Aaron
    Faulkner, Nathan
    Olson, Randall J.
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2007, 144 (01) : 143 - 144
  • [9] Early Postoperative Rotational stability and its related factors of a single-piece acrylic toric intraocular lens
    Shuyi Li
    Xi Li
    Suhong He
    Qianyin Zheng
    Xiang Chen
    Xingdi Wu
    Wen Xu
    Eye, 2020, 34 : 474 - 479
  • [10] Early Postoperative Rotational stability and its related factors of a single-piece acrylic toric intraocular lens
    Li, Shuyi
    Li, Xi
    He, Suhong
    Zheng, Qianyin
    Chen, Xiang
    Wu, Xingdi
    Xu, Wen
    EYE, 2020, 34 (03) : 474 - 479