Comparison of a reference region model with direct measurement of an AIF in the analysis of DCE-MRI data

被引:82
|
作者
Yankeelov, Thomas E.
Cron, Greg O.
Addison, Christina L.
Wallace, Julia C.
Wilkins, Ruth C.
Pappas, Bruce A.
Santyr, Giles E.
Gore, John C.
机构
[1] Vanderbilt Univ, Inst Imaging Sci, Nashville, TN 37232 USA
[2] Vanderbilt Univ, Dept Radiol & Radiol Sci, Nashville, TN 37232 USA
[3] Vanderbilt Univ, Dept Biomed Engn, Nashville, TN 37232 USA
[4] Vanderbilt Univ, Dept Phys & Astron, Nashville, TN 37232 USA
[5] Catholic Univ Louvain, Biomed Magnet Resonance Unit, B-1200 Brussels, Belgium
[6] Ottawa Hlth Res Inst, Ctr Canc Therapeut, Ottawa, ON, Canada
[7] Carleton Univ, Inst Neurosci, Ottawa, ON K1S 5B6, Canada
[8] Carleton Univ, Dept Phys, Ottawa, ON K1S 5B6, Canada
[9] Hlth Canada, Consumer & Clin Radiat Protect Bur, Ottawa, ON K1A 0L2, Canada
[10] Robarts Res Inst, Imaging Res Labs, London, ON N6A 5C1, Canada
关键词
DCE-MRI; tumor pharmacokinetics; reference region; arterial input function; contrast agent;
D O I
10.1002/mrm.21131
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Models have been developed for analyzing dynamic contrast-enhanced (DCE)-MRI data that do not require measurements of the arterial input function (AIF). In this study, experimental results obtained from a reference region (FIR) analysis are compared with results of an AIF analysis in the same set of five animals (four imaged twice, yielding nine data sets), returning estimates of the volume transfer constant (K-trans) and the extravascular extracellular volume fraction (v,). Student's t-test values for comparisons of K-trans and v(e) between the two models were 0.14 (P = 0.88) and 0.85 (P > 0.4), respectively (where the high P-values indicate no significant difference between values derived from the two models); Linear regression analysis indicated there was a correlation between K-trans extracted by the two methods: r(2) = 0.80, P = 0.001 (where the low P value indicates a significant linear correlation). For v. there was no such correlation (r(2) = 0.02). The mean (absolute) percent difference between the models was 22.0% for K-trans and 28.1% for v(e). However, the FIR parameter values were much less precise than the AIF method. The mean SDs for K-trans and v(e) for the RR analysis were 0.024 min(-1) and 0.06, respectively, vs. 0.002 min(-1) and 0.03 for AIF analysis. Magn Reson Med 57:353-361, 2007. (c) 2007 Wiley-Liss, Inc.
引用
收藏
页码:353 / 361
页数:9
相关论文
共 50 条
  • [1] Comparison of analytical and numerical analysis of the reference region model for DCE-MRI
    Lee, Joonsang
    Cardenas-Rodriguez, Julio
    Pagel, Mark D.
    Platt, Simon
    Kent, Marc
    Zhao, Quri
    [J]. MAGNETIC RESONANCE IMAGING, 2014, 32 (07) : 845 - 853
  • [2] A Constrained Linear Reference Region Model For DCE-MRI
    Ahmed, Z.
    El Naqa, I.
    Levesque, I. R.
    [J]. MEDICAL PHYSICS, 2015, 42 (06) : 3735 - 3735
  • [3] Incorporating a vascular term into a reference region model for the analysis of DCE-MRI data: a simulation study
    Faranesh, A. Z.
    Yankeelov, T. E.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (10): : 2617 - 2631
  • [4] Repeatability of a reference region model for analysis of murine DCE-MRI data at 7T
    Yankeelov, Thomas E.
    DeBusk, Laura M.
    Billheimer, D. Dean
    Luci, Jeffrey J.
    Lin, P. Charles
    Price, Ronald R.
    Gore, John C.
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2006, 24 (05) : 1140 - 1147
  • [5] An analysis of the pharmacokinetic parameter ratios in DCE-MRI using the reference region model
    Lee, Joonsang
    Platt, Simon
    Kent, Marc
    Zhao, Qun
    [J]. MAGNETIC RESONANCE IMAGING, 2012, 30 (01) : 26 - 35
  • [6] Quantitative pharmacokinetic analysis of DCE-MRI data without an arterial input function: a reference region model
    Yankeelov, TE
    Luci, JJ
    Lepage, M
    Li, R
    Debusk, L
    Lin, PC
    Price, RR
    Gore, JC
    [J]. MAGNETIC RESONANCE IMAGING, 2005, 23 (04) : 519 - 529
  • [7] An extended reference region model for DCE-MRI that accounts for plasma volume
    Ahmed, Zaki
    Levesque, Ives R.
    [J]. NMR IN BIOMEDICINE, 2018, 31 (07)
  • [8] Modified Maximum Entropy Method and Estimating the AIF via DCE-MRI Data Analysis
    Amini Farsani, Zahra
    Schmid, Volker J.
    [J]. ENTROPY, 2022, 24 (02)
  • [9] A Novel Cost Function in AIF Model Fitting for DCE-MRI Studies
    He, R.
    Wahid, K.
    McDonald, B.
    Ding, Y.
    Mohamed, A.
    Elgohari, B.
    Hutcheson, K.
    Fuller, C.
    Lai, S.
    [J]. MEDICAL PHYSICS, 2020, 47 (06) : E570 - E570
  • [10] Study of onset time-shift and injection duration in DCE-MRI: a comparison of a reference region model with the general kinetic model
    Hsiao, Ing-Tsung
    Liao, Yen-Peng
    Liu, Ho-Ling
    [J]. NMR IN BIOMEDICINE, 2010, 23 (04) : 375 - 381