The present research investigates the heat transfer characteristics in an equilateral triangular channel to simulate the leading edge cooling passage of a gas turbine blade. The experiments are conducted for the stationary and rotating ribbed channel with three different attack angles (45 degrees, 90 degrees and 135 degrees). Square ribs are installed in a staggered manner on the pressure and suction side surfaces of the channel. The rib height to channel hydraulic diameter ratio (e/D-h) is 0.079 and the rib-to-rib pitch (p) is 8 times of the rib height. To measure regional-averaged heat transfer coefficients in the channel, two rows of copper blocks with heaters are installed on each surface. The rotation number ranges from 0.0 to 0.1 for the fixed Reynolds number of 10,000. Inlet coolant-to-surface density ratio is about 0.2. For the channel with 90 degrees ribs, the heat transfer rates of all regions have similar values for stationary case. However, for the rotating channel, heat transfer coefficients on the pressure side surface are significantly increased while the suction side surface has quite low heat transfer coefficients due to a single rotating secondary flow induced by Coriolis force. For the channel with angled rib arrangements, a pair of counter-rotating vortices is induced by the angled rib arrangements. High heat transfer coefficients are obtained on the regions near the inner wall for 45 degrees angled ribbed channel and near the leading edge for the 135 degrees angled ribbed channel. The heat transfer coefficients in rotating channel with angled ribs are almost the same as those of stationary case for the tested conditions because the secondary flow dominates the heat transfer. The channel with angled ribs consistently yields better thermal performance than the transverse ribbed channel for the test conditions of the present study.
引用
收藏
页码:777 / 785
页数:9
相关论文
共 50 条
  • [1] Heat transfer and flow temperature measurements in a rotating triangular channel with various rib arrangements
    Dong Hyun Lee
    Dong-Ho Rhee
    Kyung Min Kim
    Hyung Hee Cho
    Hee-Koo Moon
    [J]. Heat and Mass Transfer, 2009, 45 : 1543 - 1553
  • [2] Heat transfer and flow temperature measurements in a rotating triangular channel with various rib arrangements
    Lee, Dong Hyun
    Rhee, Dong-Ho
    Kim, Kyung Min
    Cho, Hyung Hee
    Moon, Hee-Koo
    [J]. HEAT AND MASS TRANSFER, 2009, 45 (12) : 1543 - 1553
  • [3] Detailed Measurement of Heat/Mass Transfer in a Rotating Equilateral Triangular Channel with Smooth Walls
    Kim, Kyung Min
    Lee, Dong Hyun
    Cho, Hyung Hee
    [J]. TRANSACTIONS OF THE KOREAN SOCIETY OF MECHANICAL ENGINEERS B, 2007, 31 (07) : 628 - 634
  • [4] Effect of various rib arrangements on heat transfer in a semicylinder channel with effusion flow
    Zhao, Qing-Yang
    Chung, Heeyoon
    Jung, Eui Yeop
    Cho, Hyung Hee
    [J]. NUMERICAL HEAT TRANSFER PART A-APPLICATIONS, 2017, 71 (05) : 547 - 559
  • [5] Heat Transfer and Pressure Drop Measurements of Rotating Rib-Roughened Parallelogram Channel
    Chang, S. W.
    Liou, T. -M.
    Lee, T. -H.
    [J]. JOURNAL OF THERMOPHYSICS AND HEAT TRANSFER, 2012, 26 (01) : 98 - 107
  • [6] Shape optimization of staggered ribs in a rotating equilateral triangular cooling channel
    Moon, Mi-Ae
    Park, Min-Jung
    Kim, Kwang-Yong
    [J]. HEAT AND MASS TRANSFER, 2014, 50 (04) : 533 - 544
  • [7] Shape optimization of staggered ribs in a rotating equilateral triangular cooling channel
    Mi-Ae Moon
    Min-Jung Park
    Kwang-Yong Kim
    [J]. Heat and Mass Transfer, 2014, 50 : 533 - 544
  • [8] Enhancement of heat transfer by nanofluids and orientations of the equilateral triangular obstacle
    Bovand, M.
    Rashidi, S.
    Esfahani, J. A.
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2015, 97 : 212 - 223
  • [9] Heat transfer and pressure drop in the roughened equilateral triangular duct
    Ahn, SW
    Son, KP
    [J]. INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2002, 29 (04) : 479 - 488
  • [10] Local heat/mass transfer with various rib arrangements in impingement/effusion cooling system with crossflow
    Rhee, DH
    Nam, YW
    Cho, HH
    [J]. JOURNAL OF TURBOMACHINERY-TRANSACTIONS OF THE ASME, 2004, 126 (04): : 615 - 626