Electrodeposition of reduced graphene oxide on a Pt electrode and its use as amperometric sensor in microchip electrophoresis

被引:20
|
作者
Lucca, Bruno Gabriel [1 ]
de Lima, Fabio [1 ]
Coltro, Wendell K. T. [2 ]
Ferreira, Valdir Souza [1 ]
机构
[1] Univ Fed Mato Grosso do Sul, Inst Quim, BR-79074460 Campo Grande, MS, Brazil
[2] Univ Fed Goias, Inst Quim, Goiania, Go, Brazil
关键词
Electrochemical deposition; Electrochemical detection; Graphene; Microfluidic devices; Modified electrodes; COMPOSITE ELECTRODE; ASCORBIC-ACID; CAPILLARY-ELECTROPHORESIS; BIOACTIVE CONSTITUENTS; URIC-ACID; CARBON; FILMS; FABRICATION; REDUCTION; FE(CN)(6)(3-)/FE(CN)(6)(4-);
D O I
10.1002/elps.201500092
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
This report describes the development and application of a novel graphene-modified electrode to be used as amperometric sensor in microchip electrophoresis (ME) devices. The modified electrode was achieved based on electroreduction of graphene oxide on an integrated Pt working electrode of a commercial ME device. The surface modification was characterized by SEM and cyclic voltammetry techniques. The results indicated that graphene sheets were successfully deposited exhibiting higher surface conductivity and greater electrode sensitivity. The performance of the modified electrode for the amperometric detection on ME devices has been demonstrated by the separation and detection of an anionic mixture containing iodide and ascorbate. The graphene-modified electrode provided significantly higher sensitivity (896.7 vs. 210.9 pA/M for iodide and 217.8 vs. 127.8 pA/M for ascorbate), better separation efficiencies (3400 vs. 700 plates/m for iodide and 10000 vs. 2400 plates/m for ascorbate), enhanced peak resolutions (1.6 vs. 1.0), and LODs (1.5 vs. 5.3 M for iodide and 3.1 vs. 7.3 M for ascorbate) in comparison with the unmodified Pt electrode. The proposed amperometric sensor was successfully applied for the analysis of ascorbic acid (through its anionic form) in a commercial medicine sample, and the results achieved were in agreement with the value provided by the supplier. Based on the data here presented, the modified graphene electrode shows great promise for ME applications.
引用
收藏
页码:1886 / 1893
页数:8
相关论文
共 50 条
  • [1] Amperometric hydrazine sensor based on the use of Pt-Pd nanoparticles placed on reduced graphene oxide nanosheets
    Ghasemi, Shahram
    Hosseini, Sayed Reza
    Hasanpoor, Faeze
    Nabipour, Shima
    [J]. MICROCHIMICA ACTA, 2019, 186 (09) : 601
  • [2] Amperometric hydrazine sensor based on the use of Pt-Pd nanoparticles placed on reduced graphene oxide nanosheets
    Shahram Ghasemi
    Sayed Reza Hosseini
    Faeze Hasanpoor
    Shima Nabipour
    [J]. Microchimica Acta, 2019, 186
  • [3] An Amperometric Hydrogen Peroxide Sensor Based on Reduced Graphene Oxide/Carbon Nanotubes/Pt NPs Modified Glassy Carbon Electrode
    Zhang, Yuanyuan
    Cao, Qi
    Zhu, Fengmei
    Xu, Hedan
    Zhang, Yang
    Xu, Wenfeng
    Liao, Xiaoling
    [J]. INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2020, 15 (09): : 8771 - 8785
  • [4] Highly selective amperometric nitrite sensor based on chemically reduced graphene oxide modified electrode
    Mani, Veerappan
    Periasamy, Arun Prakash
    Chen, Shen-Ming
    [J]. ELECTROCHEMISTRY COMMUNICATIONS, 2012, 17 : 75 - 78
  • [5] Direct electrodeposition of reduced graphene oxide on glassy carbon electrode and its electrochemical application
    Chen, Liuyun
    Tang, Yanhong
    Wang, Ke
    Liu, Chengbin
    Luo, Shenglian
    [J]. ELECTROCHEMISTRY COMMUNICATIONS, 2011, 13 (02) : 133 - 137
  • [6] Electrochemical behavior of isofraxidin at an electrodeposition reduced graphene oxide electrode and its analytical application
    Wu, Junjun
    Wang, Lu
    Xie, Zhengkun
    Zou, Lina
    Ye, Baoxian
    [J]. ANALYTICAL METHODS, 2016, 8 (07) : 1473 - 1482
  • [7] Amperometric enzyme-free glucose sensor based on the use of a reduced graphene oxide paste electrode modified with electrodeposited cobalt oxide nanoparticles
    Heidari, Hassan
    Habibi, Esmaeil
    [J]. MICROCHIMICA ACTA, 2016, 183 (07) : 2259 - 2266
  • [8] Amperometric enzyme-free glucose sensor based on the use of a reduced graphene oxide paste electrode modified with electrodeposited cobalt oxide nanoparticles
    Hassan Heidari
    Esmaeil Habibi
    [J]. Microchimica Acta, 2016, 183 : 2259 - 2266
  • [9] Electrodeposition of Polypyrrole/Reduced Graphene Oxide/Iron Oxide Nanocomposite as Supercapacitor Electrode Material
    Eeu, Y. C.
    Lim, H. N.
    Lim, Y. S.
    Zakarya, S. A.
    Huang, N. M.
    [J]. JOURNAL OF NANOMATERIALS, 2013, 2013
  • [10] Preparation of a reduced graphene oxide hydrogel by Ni ions and its use in a supercapacitor electrode
    Van Hoang Luan
    Chung, Jin Suk
    Hur, Seung Hyun
    [J]. RSC ADVANCES, 2015, 5 (29) : 22753 - 22758