How does total knee replacement technique influence polyethylene wear?

被引:26
|
作者
Massin, P. [1 ,2 ]
机构
[1] Clin Hartmann, 26 Blvd Victor Hugo, F-92200 Neuilly S Seine, France
[2] Univ Paris Diderot, Sorbonne Paris Cite, EA REMES Rech Clin Coordonnee Ville Hop Methodol, F-75010 Paris, France
关键词
Polyethylene wear; Total knee replacement; Tibiofemoral alignment; Ligament balance; FEMORAL COMPONENT; ALL-POLYETHYLENE; SURFACE DAMAGE; TIBIAL INSERTS; FOLLOW-UP; ARTHROPLASTY; PROSTHESES; ALIGNMENT; FAILURE; TKA;
D O I
10.1016/j.otsr.2016.06.024
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
In knee prostheses, wear is inherent to the tribology of the imperfectly congruent surfaces, one in chromium-cobalt alloy, the other in polyethylene. It is a multifactorial phenomenon, involving the properties of the respective materials and implant design, but also implant functioning, as determined by the implantation technique. There are still dark corners in the implantation charge book, especially concerning minimal insert thickness, the adjustment of tibiofemoral alignment and ligament balance. A review of the literature revealed consensus regarding minimal insert thickness (8 mm), tibiofemoral alignment (to be kept within 5 on either side of the neutral axis) and ligament balance (identical collateral ligament tension in both extension and flexion spaces). Finer adjustment seems desirable. Tibiofemoral alignment is probably customizable according to individual patient morphology and weight. The rotational alignment of the components should allow harmonious patellar engagement. Classic ligament balance rules underestimate sagittal laxity, which needs checking to prevent paradoxical movement accelerating polymer delamination. Navigation techniques or specific ancillaries can help optimize implant component alignment. Control of sagittal laxity may require specific adaptation, notably in the flexion space. Improved implantation technique could postpone wear onset until beyond the 10th or even 20th postoperative year, barring material failure for other reasons. (C) 2016 Elsevier Masson SAS. All rights reserved.
引用
收藏
页码:S21 / S27
页数:7
相关论文
共 50 条
  • [1] Prediction of polyethylene wear after total knee replacement
    Terrier, A.
    Ramondetti, S.
    Jolles, B. M.
    Pioletti, D. P.
    [J]. COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2010, 13 : 139 - 140
  • [2] Influence of design and bearing material on polyethylene wear particle generation in total knee replacement
    Utzschneider, S.
    Paulus, A.
    Datz, J. -C.
    Schroeder, C.
    Sievers, B.
    Wegener, B.
    Jansson, V.
    [J]. ACTA BIOMATERIALIA, 2009, 5 (07) : 2495 - 2502
  • [3] Effect of joint laxity on polyethylene wear in total knee replacement
    Kretzer, J. Philippe
    Jakubowitz, Eike
    Sonntag, Robert
    Hofmann, Kerstin
    Heisel, Christian
    Thomsen, Marc
    [J]. JOURNAL OF BIOMECHANICS, 2010, 43 (06) : 1092 - 1096
  • [4] Influence of conformity on the wear of total knee replacement: An experimental study
    Brockett, Claire L.
    Carbone, Silvia
    Fisher, John
    Jennings, Louise M.
    [J]. PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2018, 232 (02) : 127 - 134
  • [5] WEAR AND CONFORMITY IN TOTAL KNEE REPLACEMENT
    TRENT, PS
    WALKER, PS
    [J]. WEAR, 1976, 36 (02) : 175 - 187
  • [6] HOW DOES FRONTAL PLANE ALIGNMENT OF A TOTAL KNEE REPLACEMENT INFLUENCE BIOMECHANICAL FUNCTION AND LOADING?
    Williams, D. E.
    Metcalfe, A.
    Jones, P.
    Madete, J.
    Whatling, G.
    Kempshall, P.
    Lyons, K.
    Forster, M.
    Holt, C.
    [J]. OSTEOARTHRITIS AND CARTILAGE, 2018, 26 : S388 - S389
  • [7] What design factors influence wear behavior in total knee replacement?
    [J]. IMPLANT WEAR IN TOTAL JOINT REPLACEMENT: CLINICAL AND BIOLOGICAL ISSUES, MATERIAL AND DESIGN CONSIDERATIONS, 2001, : 156 - 169
  • [8] Polyethylene wear in total hip and knee arthroplasties
    Department of Mechanical Engineering, University of Memphis, Memphis, TN 38152, United States
    [J]. J. BIOMED. MATER. RES., 1 (55-75):
  • [9] Polyethylene wear in total hip and knee arthroplasties
    Lewis, G
    [J]. JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1997, 38 (01): : 55 - 75
  • [10] Assessment of polyethylene wear in total hip replacement
    Devane, PA
    Horne, JG
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1999, (369) : 59 - 72