limits and potentialities of the use of CBCT for dose calculation in adaptive radiotherapy

被引:4
|
作者
Meroni, S. [1 ]
Mongioj, V. [1 ]
Giandini, T. [1 ]
Bonfantini, F. [1 ]
Cavallo, A. [1 ]
Carrara, M. [1 ]
Stucchi, C. [1 ]
Cavatorta, C. [1 ]
Pignoli, E. [1 ]
机构
[1] Fdn IRCCS Ist Nazl Tumori, Med Phys, Milan, Italy
关键词
D O I
10.1016/S0167-8140(16)33073-0
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
EP-1822
引用
收藏
页码:S854 / S855
页数:2
相关论文
共 50 条
  • [1] Technical note: Phantom-based evaluation of CBCT dose calculation accuracy for use in adaptive radiotherapy
    Wessels, Claas
    Strzelecki, Adam
    Plamondon, Mathieu
    Lehmann, Mathias
    Peterlik, Igor
    Paysan, Pascal
    Nagy, Balazs
    Heinz, Alexander
    Seghers, Dieter
    Thompson, Stephen
    Scheib, Stefan G.
    MEDICAL PHYSICS, 2024, : 7492 - 7499
  • [2] Quantification of the HU Variation on KV CBCT for Direct Dose Calculation in Adaptive Radiotherapy
    Givehchi, N.
    Strzelecki, A.
    Lehmann, M.
    Plamondon, M.
    Scheib, S.
    MEDICAL PHYSICS, 2020, 47 (06) : E549 - E549
  • [3] CBCT dose calculation in head and neck adaptive radiotherapy: accuracy assessment of four methods
    Barateau, A.
    Perichon, N.
    Herve, C.
    Henry, O.
    Castelli, J.
    Chajon, E.
    De Crevoisier, R.
    Lafond, C.
    RADIOTHERAPY AND ONCOLOGY, 2018, 127 : S528 - S529
  • [4] Calibration and validation of kV-CBCT in room imaging for dose calculation and adaptive radiotherapy
    Soumokil-de Bree, M.
    Rosario, T. S.
    Palacios, M. A.
    RADIOTHERAPY AND ONCOLOGY, 2015, 115 : S80 - S81
  • [5] A Critical Look at CBCT-Based Dose Calculation Accuracy as It Is Applied to Adaptive Radiotherapy
    Buele, A. Bejarano
    Sperling, N.
    Parsai, E.
    MEDICAL PHYSICS, 2016, 43 (06) : 3346 - 3346
  • [6] Dose calculation accuracy using cone-beam CT (CBCT) for pelvic adaptive radiotherapy
    Guan, Huaiqun
    Dong, Hang
    PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (20): : 6239 - 6250
  • [7] Utilizing CBCT data for dose calculation in adaptive IMPT
    Kurz, C.
    Kamp, F.
    Park, Y. K.
    Winey, B. A.
    Sharp, G. C.
    Rit, S.
    Hansen, D.
    Reiner, M.
    Nijhuis, R.
    Ganswindt, U.
    Thieke, C.
    Belka, C.
    Parodi, K.
    Landry, G.
    RADIOTHERAPY AND ONCOLOGY, 2016, 118 : S64 - S65
  • [8] Accuracy of dose calculation on iterative CBCT for head and neck radiotherapy
    Washio, Hayate
    Ohira, Shingo
    Funama, Yoshinori
    Ueda, Yoshihiro
    Isono, Masaru
    Inui, Shoki
    Miyazaki, Masayoshi
    Teshima, Teruki
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2021, 86 : 106 - 112
  • [9] Feasibility of CycleGAN Enhanced Low Dose CBCT Imaging for Prostate Radiotherapy Dose Calculation
    Chan, Y.
    Li, M.
    Parodi, K.
    Belka, C.
    Landry, G.
    Kurz, C.
    MEDICAL PHYSICS, 2022, 49 (06) : E611 - E611
  • [10] Feasibility of CycleGAN enhanced low dose CBCT imaging for prostate radiotherapy dose calculation
    Chan, Y.
    Li, M.
    Parodi, K.
    Belka, C.
    Landry, G.
    Kurz, C.
    PHYSICS IN MEDICINE AND BIOLOGY, 2023, 68 (10):