Cardiac Effort to Compare Clinic and Remote 6-Minute Walk Testing in Pulmonary Arterial Hypertension

被引:8
|
作者
Lachant, Daniel [1 ]
Kennedy, Ethan [2 ]
Derenze, Blaise [3 ]
Light, Allison [1 ]
Lachant, Michael [1 ]
White, R. James [1 ]
机构
[1] Univ Rochester, Med Ctr, Div Pulm & Crit Care Med, Rochester, NY 14642 USA
[2] Univ New England, Coll Osteopath Med, Biddeford, ME USA
[3] Univ Rochester, Rochester, NY USA
基金
美国国家卫生研究院;
关键词
6-min walk test; heart rate; pulmonary arterial hypertension; remote; PHYSICAL-ACTIVITY; END-POINT;
D O I
10.1016/j.chest.2022.06.025
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
BACKGROUND: The SARS-CoV-2 pandemic has limited objective physiologic assessments. A standardized remote alternative is not currently available. "Cardiac effort" (CE), that is, the total number of heart beats divided by the 6-min walk test (6MWT) distance (beats/m), has improved reproducibility in the 6MWT and correlated with right ventricular function in pulmonary arterial hypertension.RESEARCH QUESTION: Can a chest-based accelerometer estimate 6MWT distance remotely? Is remote cardiac effort more reproducible than 6MWT distance when compared with clinic assessment?STUDY DESIGN AND METHODS: This was a single-center, prospective observational study, with institutional review board approval, completed between October 2020 and April 2021. Group 1 subjects with pulmonary arterial hypertension, receiving stable therapy for > 90 days, completed four to six total 6MWTs during a 2-week period to assess reproducibility. The first and last 6MWTs were performed in the clinic; two to four remote 6MWTs were completed at each participant's discretion. Masks were not worn. BioStamp nPoint sensors (MC10) were worn on the chest to measure heart rate and accelerometry. Two blinded readers counted laps, using accelerometry data obtained on the clinic or user-defined course. Averages of clinic variables and remote variables were used for Wilcoxon matched-pairs signed rank tests, Bland-Altman plots, or Spearman correlation coefficients.RESULTS: Estimated 6MWT distance, using the MC10, correlated strongly with directly measured 6MWT distance (r = 0.99; P < .0001; in 20 subjects). Remote 6MWT distances were shorter than clinic 6MWT distances: 405 m (330-464 m) vs 389 m (312-430 m) (P = .002). There was no difference between in-clinic and remote CE: 1.75 beats/m (1.48-2.20INTERPRETATION: Remote 6MWT was feasible on a user-defined course; 6MWT distance was shorter than clinic distance. CE calculated by chest heart rate and accelerometer-estimated distance provides a reproducible remote assessment of exercise tolerance, comparable to the clinic-measured value. CHEST 2022; 162(6):1340-1348
引用
收藏
页码:1340 / 1348
页数:9
相关论文
共 50 条
  • [21] Heart rate recovery in 1 minute after the 6-minute walk test predicts adverse outcomes in pulmonary arterial hypertension
    Rezende, Camila Farnese
    Mancuzo, Eliane Viana
    Correa, Ricardo de Amorim
    PLOS ONE, 2022, 17 (05):
  • [22] Exercise Limitation in Pulmonary Hypertension - Physiological Insights into the 6-Minute Walk Test
    Kremer, Nils
    Schaefer, Simon
    Yogeswaran, Athiththan
    Rako, Zvonimir
    Ghofrani, Hossein-Ardeschir
    Seeger, Werner
    Kojonazarov, Baktybek
    Heerdt, Paul M.
    Tedford, Ryan J.
    Tello, Khodr
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2024, 210 (12) : 1486 - 1490
  • [23] Value of Impedance Cardiography during 6-Minute Walk Test in Pulmonary Hypertension
    Tonelli, Adriano R.
    Alkukhun, Laith
    Arelli, Vineesha
    Ramos, Jose
    Newman, Jennie
    McCarthy, Kevin
    Pichurko, Bohdan
    Minai, Omar A.
    Dweik, Raed A.
    CTS-CLINICAL AND TRANSLATIONAL SCIENCE, 2013, 6 (06): : 474 - 480
  • [24] The 6-Minute Walk Test as a Primary Endpoint in Clinical Trials for Pulmonary Hypertension
    Rich, Stuart
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2012, 60 (13) : 1202 - 1203
  • [25] Ambrisentan improves 6-minute walk distance and decreases brain natriuretic peptide in patients with pulmonary arterial hypertension
    Galie, N.
    Olschewsky, H.
    Ghofrani, H. A.
    Kramer, M. R.
    Wiens, B. L.
    Dufton, C.
    Rubin, L. J.
    EUROPEAN HEART JOURNAL, 2006, 27 : 832 - 832
  • [26] Validation of the 6-Minute Walk in Patients With Pulmonary Arterial Hypertension Trying to Fit a Square Peg Into a Round Hole?
    Farber, Harrison W.
    CIRCULATION, 2012, 126 (03) : 258 - 260
  • [27] Remote 6-Minute-Walk Testing in Patients with Pulmonary Hypertension: Further Validation Needed?
    Helgeson, Scott A.
    Burger, Charles D.
    Moss, John E.
    Zeiger, Tonya K.
    Taylor, Bryan J.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2022, 206 (05) : 650 - 651
  • [28] Echocardiography, 6-Minute Walk Distance, and Distance-Saturation Product as Predictors of Pulmonary Arterial Hypertension in Idiopathic Pulmonary Fibrosis
    Modrykamien, Ariel M.
    Gudavalli, Ravindra
    McCarthy, Kevin
    Parambil, Joseph
    RESPIRATORY CARE, 2010, 55 (05) : 584 - 588
  • [29] Improvement in Cardiac Effort, 6-minute Walk Distance, and Metabolic Parameters After Acute Pulmonary Embolism but Not Activity Time
    Roto, D.
    Williams, A.
    Haight, D.
    Norton, K.
    White, R.
    Lachant, D. J.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2024, 209
  • [30] Usefulness of the 6-minute walk test as a screening test for pulmonary arterial enlargement in COPD
    Oki, Yutaro
    Kaneko, Masahiro
    Fujimoto, Yukari
    Sakai, Hideki
    Misu, Shogo
    Mitani, Yuji
    Yamaguchi, Takumi
    Yasuda, Hisafumi
    Ishikawa, Akira
    INTERNATIONAL JOURNAL OF CHRONIC OBSTRUCTIVE PULMONARY DISEASE, 2016, 11 : 2869 - 2875