Tapered titanium cementless total hip replacements - A 10-to 13-year followup study

被引:0
|
作者
Bourne, RB [1 ]
Rorabeck, CH [1 ]
Patterson, JJ [1 ]
Guerin, J [1 ]
机构
[1] Univ Western Ontario, Hlth Sci Ctr, London, ON N6A 5A5, Canada
关键词
D O I
暂无
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The 10- to-13 year performance of 307 Mallory Head cementless tapered total hip replacements in 283 patients was assessed. Eighty-five percent of patients had a diagnosis of osteoarthritis. Fifty-one percent of patients were women. The mean patient age was 64 +/- 10 years. The Hex Loc cementless acetabular component and titanium alloy femoral heads were used in each patient. At final followup, 37 (13%) patients died, 32 (10%) had revision surgery, and two (1%) were lost to followup. No femoral stem was revised for aseptic loosening, but one was revised because of sepsis and one was revised because of a periprosthetic fracture. Wear, osteolysis, and loosening were problems with the Hex Loc cementless acetabular components and 31 (10%) acetabular components required revision because of these mechanisms. The mean Harris hip score at final followup of the remaining patients was 87 +/- 14 points. Three percent of these patients had thigh pain. Radiographic assessment revealed that no femoral stem or acetabular socket was definitely or probably loose. Three-dimensional wear assessment using the Devane technique was 0.35 nim per year. The Mallory Head cementless, tapered femoral component performed well in the patients in the current study, but unfortunately, the clinical results were compromised by the use of a suboptimal cementless acetabular component, the use of polyethylene that was gamma-irradiated in air, and by the use of titanium alloy femoral heads. Future developments obviously will be in the areas of better acetabular component design, alternate polyethylene sterilization methods, and enhancements of the femoral stein in terms of offset choices, neck design, and perhaps ingrowth surface.
引用
收藏
页码:112 / 120
页数:9
相关论文
共 50 条
  • [1] Hydroxyapatite femoral stems for total hip arthroplasty - 10-to 13-year followup
    D'Antonio, JA
    Capello, WN
    Manley, MT
    Geesink, R
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2001, (393) : 101 - 111
  • [2] Omnifit cementless total hip arthroplasty - A 10-year average followup
    Hellman, EJ
    Capello, WN
    Feinberg, JR
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1999, (364) : 164 - 174
  • [3] Cementless titanium tapered-wedge femoral stem - 10-to 15-year follow-up
    Marshall, AD
    Mokris, JG
    Reitman, RD
    Dandar, A
    Mauerhan, DR
    JOURNAL OF ARTHROPLASTY, 2004, 19 (05): : 546 - 552
  • [4] Cementless total hip arthroplasty in patients with rheumatoid arthritis using a tapered designed titanium hip stem minimum: 10-year results
    Hans D. Carl
    Jan Ploetzner
    Bernd Swoboda
    Gerd Weseloh
    Lutz Arne Mueller
    Rheumatology International, 2011, 31 : 353 - 359
  • [5] Cementless total hip arthroplasty in patients with rheumatoid arthritis using a tapered designed titanium hip stem minimum: 10-year results
    Carl, Hans D.
    Ploetzner, Jan
    Swoboda, Bernd
    Weseloh, Gerd
    Mueller, Lutz Arne
    RHEUMATOLOGY INTERNATIONAL, 2011, 31 (03) : 353 - 359
  • [6] The uncemented fully textured Lord hip prosthesis - A 10-to 15-year followup study
    Keisu, KS
    Mathiesen, EB
    Lindgren, JU
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2001, (382) : 133 - 142
  • [7] Minimal 10-year results of a tapered cementless femoral component in total hip arthroplasty
    Mallory, TH
    Lombardi, AV
    Leith, JR
    Fujita, H
    Hartman, JF
    Capps, SG
    Kefauver, CA
    Adams, JB
    Vorys, GC
    JOURNAL OF ARTHROPLASTY, 2001, 16 (08): : 49 - 54
  • [8] A quantitative analysis of bone support comparing cementless tapered and distal fixation total hip replacements
    Howard, JL
    Hui, AJ
    Bourne, RB
    McCalden, RW
    MacDonald, SJ
    Rorabeck, CH
    JOURNAL OF ARTHROPLASTY, 2004, 19 (03): : 266 - 273
  • [9] Minimum 10-year results of a tapered cementless hip replacement
    Sakalkale, DP
    Eng, K
    Hozack, WJ
    Rothman, RH
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1999, (362) : 138 - 144
  • [10] Minimum 10-Year Follow-Up of Cementless Total Hip Arthroplasty Using a Contemporary Triple-Tapered Titanium Stem
    Carlson, Samuel W.
    Goetz, Devon D.
    Liu, Steve S.
    Greiner, Justin J.
    Callaghan, John J.
    JOURNAL OF ARTHROPLASTY, 2016, 31 (10): : 2231 - 2236