On-line hemodiafiltration with pre- and postdilution: A comparison of efficacy

被引:59
|
作者
Ahrenholz, P
Winkler, RE
Ramlow, W
Tiess, M
Muller, W
机构
[1] BioArtProducts GmbH, Rostock
[2] Dialyse-Gemeinschaft Nord E.V., Rostock
[3] Laborarztpraxis Dr. Müller, Rostock
[4] BioArtProducts GmbH, D-18107 Rostock
来源
关键词
on-line HDF; postdilution; predilution; clearance; efficacy;
D O I
10.1177/039139889702000206
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Since the introduction of on-line substituate preparation, high substituate rates (Q(s)) in pre- and postdilution for hemodiafiltration (HDF) procedures can be realized. During postdilution HDF (POD-HDF) and additional convective removal is possible, but in vivo Q(s) is limited to approx. 1/3Q(b) (bloodflow). With predilution HDF (PRD-HDF) higher Q(s) and therefore high convective transport rates by ultrafiltration can be reached. On the other hand the blood concentration is diminished by predilution. Further decrease of the diffusive transport is caused by reduced dialysate flow Q(d) due to separation of the substituate from the dialysate (Fresenius 4008 On-Line HDF; Gambro AK100 Ultra). The theoretical description of the combined diffusive-convective transport is limited to I-dimensional models and small UP-rates. Therefore for practical and theoretical purposes the assessment of the efficacy of on-line PRD-HDF and POD-HDF in different molecular weight ranges is desirable. By means of in vitro experiments the effective clearances K-eff of hemodialysis (HD dialyzer: Fresenius F60) for urea, creatinine, vitamin B12 and inulin were compared with measured and theoretical K-eff of POD- and PRD-HDF: The theoretical expectation is confirmed that K-eff for small molecular weight substances decreases slightly with PRD-HDF and increases for larger molecules. In the case of POD-HDF K-eff for small molecular weight substances increases slightly and strongly for larger molecules. in vivo experiments were performed to measure the real substance removal from patient's blood and to figure out the impact of dialysate flow (collection of the used dialysate during the ii treatment hour and concentration measurements for urea, creatinine, phosphate, beta(2)-MG). The results show that the substraction of Q(s) from Q(d) reduces K-eff for urea, creatinine and phosphate but not for beta(2)-MG. PRD-HDF with Q(d) = 500 ml/min is significantly less effective for small molecules than HD. There is no significant difference of K-eff for urea, creatinine, phosphate during HD and PRD-HDF with Q(d) = 800 ml/min, but a significant increase of 10-15% for POD-HDF. K-eff for beta(2)-MG increases by 75% for PRD-HDF and 95% for POD-HDF compared with HD (Q(d) = 500 ml/min).
引用
收藏
页码:81 / 90
页数:10
相关论文
共 50 条
  • [1] On-line hemodiafiltration with pre- and postdilution: impact on the acid-base status
    Ahrenholz, P
    Winkler, RE
    Ramlow, W
    Tiess, M
    Thews, O
    [J]. INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 1998, 21 (06): : 321 - 327
  • [2] Different solute transport profile in pre- and postdilution hemodiafiltration with on-line production of bicarbonate infusate.
    Kiss, D
    Loffel, M
    Muser, J
    [J]. JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 1996, 7 (09): : A0818 - A0818
  • [3] Different solute transport profile in pre- and postdilution hemodiafiltration with on-line production of bicarbonate infusate.
    Kiss, D
    Loffel, M
    Muser, J
    [J]. KIDNEY INTERNATIONAL, 1997, 52 (05) : 1425 - 1425
  • [4] Diafilters for Predilution and Postdilution On-Line Hemodiafiltration
    Yamashita, Akihiro C.
    [J]. BLOOD PURIFICATION, 2013, 35 : 29 - 33
  • [5] MIXED PRE-POST DILUTION HEMODIAFILTRATION: A COMPARISON OF SOLUTE ELIMINATION WITH PRE- AND POSTDILUTION MODES
    Wang, Bei
    Wang, Kai
    [J]. NEPHROLOGY DIALYSIS TRANSPLANTATION, 2013, 28 : 30 - 30
  • [6] Optimized convective transport with automated pressure control in on-line postdilution hemodiafiltration
    Joyeux, V.
    Sjpkens, Y.
    Haddj-Elmrabet, A.
    Bijvoet, A. J.
    Nilsson, L. -G.
    [J]. INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2008, 31 (11): : 928 - 936
  • [7] Optimized convective transport with automated pressure control in on-line postdilution hemodiafiltration
    Joyeux, V.
    Sijpkens, Y.
    Haddj-Elmrabet, A.
    Bijvoet, A.J.
    Nilsson, Lars-Göran
    [J]. International Journal of Artificial Organs, 2008, 31 (11): : 928 - 936
  • [8] Evaluation of pre- and postdilutional on-line hemodiafiltration adequacy by partial dialysate quantification and on-line urea monitor
    Lim, PS
    Lee, HP
    Kho, B
    Yu, YL
    Chang, SC
    Lin, YY
    Yang, CC
    Lin, YT
    Wang, TH
    Kuo, SY
    Lin, LC
    [J]. BLOOD PURIFICATION, 1999, 17 (04) : 199 - 205
  • [9] COMPARISON OF THE EFFECTS OF PRE- AND POST-DILUTION ON-LINE HEMODIAFILTRATION ON THE CELL SURFACE AND OTHER IMFLAMMATORY MARKERS
    Sakurai, Kenji
    Saito, Takeshi
    Yamauchi, Fumi
    Hosoya, Hiromi
    Kurihara, Yoshitaka
    Kurosawa, Kaori
    Ohi, Sayuri
    Suzuki, Ayumi
    Ishi, Daisuke
    Yamashita, Akihiro C.
    [J]. NEPHROLOGY DIALYSIS TRANSPLANTATION, 2016, 31 : 1493 - 1493
  • [10] PRE-/POSTDILUTION HEMOFILTRATION
    HILLION, D
    HAAS, T
    PERTUISET, N
    UZAN, M
    [J]. BLOOD PURIFICATION, 1995, 13 (05) : 241 - 245