Film Carbon Veil-Based Electrode Modified with Triton X-100 for Nitrite Determination

被引:9
|
作者
Stozhko, Natalia Yu [1 ]
Bukharinova, Maria A. [1 ]
Khamzina, Ekaterina, I [1 ]
Tarasov, Aleksey, V [1 ]
Sokolkov, Sergey, V [1 ]
机构
[1] Ural State Univ Econ, Res & Innovat Ctr Sensor Technol, Dept Phys & Chem, 8 Marta St,62, Ekaterinburg 620144, Russia
关键词
carbon veil; hot lamination; surfactant; film sensor; nitrite; natural water; sausage products; SCREEN-PRINTED ELECTRODE; VOLTAMMETRIC DETERMINATION; ELECTROCHEMICAL DETECTION; SENSITIVE DETERMINATION; SELECTIVE DETECTION; URIC-ACID; SENSOR; NANOPARTICLES; PALLADIUM; NITRATES;
D O I
10.3390/chemosensors8030078
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A film carbon veil-based electrode (FCVE) modified with non-ionic surfactant Triton X-100 (TrX100) has been developed for nitrite determination. A new simple and producible technique of hot lamination (heat sealing) has been used for the FCVE manufacturing. The paper presents the findings of investigating the FCVE and the TrX100/FCVE by using voltammetry, chronoamperometry, and scanning electron microscopy. Modification of the electrode with TrX100 improves the hydrophilic property of its surface, which results in a larger electrode active area and higher sensitivity. Optimal conditions for nitrite determination with the use of the TrX100/FCVE have been identified. The linear range (LR) and the limit of detection (LOD) are 0.1-100 mu M and 0.01 mu M, respectively. The relative standard deviation (RSD) does not exceed 2.3%. High selectivity of the sensor ensures its successful application for the analysis of real samples (sausage products and natural water). The obtained results accord well with the results of the standard spectrophotometric method.
引用
收藏
页数:17
相关论文
共 50 条
  • [1] Voltammetric Investigation of Catechol and Hydroquinone at Triton X-100 Modified Carbon Paste Electrode
    Ganesh, Pattan Siddappa
    Swamy, Bahaddurghatta Eshwaraswamy Kumara
    [J]. ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2016, 8 (05): : 615 - 628
  • [2] The Fabrication of in Situ Triton X-100 on Multi-Walled Carbon Nanotubes Modified Gold Electrode for Sensitive Determination of Caffeine
    Mukdasai, Kanit
    Mukdasai, Siriboon
    [J]. INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2018, 13 (01): : 58 - 70
  • [3] Selective Determination of Dopamine in Presence of Ascorbic Acid by using Triton X-100 Poly(Safranin) Modified Carbon Paste Electrode
    Lavanya, Manimangalam
    Reddy, Yenugu Veera Manohara
    Kiranmai, Sundupalle
    Venu, Manthrapudi
    Madhavi, Gajulapalle
    [J]. ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2015, 7 (05): : 555 - 568
  • [4] Enhanced adsorption and oxidation of Triton X-100 at an acetylene black-dihexadecyl hydrogen phosphate modified glassy carbon electrode and its application in the determination of Triton X-100 in recombinant hepatitis B vaccine
    Zhang, HJ
    Hu, C
    Hu, SS
    [J]. ANALYTICAL LETTERS, 2005, 38 (05) : 825 - 839
  • [5] Platinum decorated multi-walled carbon nanotubes/Triton X-100 modified carbon paste electrode for the sensitive amperometric determination of Paracetamol
    D'Souza, Ozma J.
    Mascarenhas, Ronald J.
    Thomas, Tony
    Basavaraja, Basavanakote M.
    Saxena, Arvind Kumar
    Mukhopadhyay, Kingsuk
    Roy, Debmalya
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2015, 739 : 49 - 57
  • [6] Electrocatalytic Response of Dopamine at Mannitol and Triton X-100 Modified Carbon Paste Electrode: A Cyclic Voltammetric Study
    Manjunatha, J. G.
    Swamy, B. E. Kumara
    Mamatha, G. P.
    Gilbert, Ongera
    Shreenivas, M. T.
    Sherigara, B. S.
    [J]. INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2009, 4 (12): : 1706 - 1718
  • [7] Highly improved electrooxidation of formaldehyde on nickel/poly (o-toluidine)/Triton X-100 film modified carbon nanotube paste electrode
    Raoof, Jahan-Bakhsh
    Ojani, Reza
    Abdi, Samaneh
    Hosseini, Sayed Reza
    [J]. INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2012, 37 (03) : 2137 - 2146
  • [8] ANODIC-STRIPPING VOLTAMMETRY WITH A TRITON X-100 MODIFIED MERCURY FILM ELECTRODE USING FLOW-INJECTION
    DALANGIN, RR
    GUNASINGHAM, H
    [J]. ANALYST, 1994, 119 (07) : 1603 - 1606
  • [9] Electrochemical Response of Dopamine at Phthalic acid and Triton X-100 Modified Carbon Paste Electrode: A cyclic voltammetry study
    Manjunatha, J. G.
    Swamy, B. E. Kumara
    Mamatha, G. P.
    Shankar, S. Sharath
    Gilbert, Ongera
    Chandrashekar, B. N.
    Sherigara, B. S.
    [J]. INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2009, 4 (10): : 1469 - 1478
  • [10] LOWRY DETERMINATION OF PROTEIN IN PRESENCE OF TRITON X-100
    WANG, CS
    SMITH, RL
    [J]. ANALYTICAL BIOCHEMISTRY, 1975, 63 (02) : 414 - 417