The cement-augmented transiliacal internal fixator (caTIFI): an innovative surgical technique for stabilization of fragility fractures of the pelvis

被引:37
|
作者
Schmitz, Paul [1 ]
Baumann, Florian [1 ]
Grechenig, Stephan [1 ]
Gaensslen, Axel [2 ]
Nerlich, Michael
Mueller, Michael B. [1 ]
机构
[1] Univ Regensburg, Clin Trauma Surg, D-93053 Regensburg, Germany
[2] Klinikum Wolfsburg, Dept Trauma Surg, Wolfsburg, Germany
来源
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED | 2015年 / 46卷
关键词
fragility fracture of pelvis; cement augmentation; transiliac screws; RING FRACTURES; COMPREHENSIVE CLASSIFICATION; INSUFFICIENCY FRACTURES; SCREW FIXATION; PLACEMENT; MORTALITY; POLYMETHYLMETHACRYLATE; PREDICTORS; ACCURATE; OUTCOMES;
D O I
10.1016/S0020-1383(15)30029-2
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Introduction: Analyzing the different age groups in a population who suffered a pelvic ring fracture it becomes obvious that there are important differences between the pelvic ring lesions of an elderly patient compared to a young adult concerning trauma mechanism, fracture pattern and therapeutic options. In the elderly patient it is very important to achieve maximum of stability if surgery is necessary in order to avoid early failure of the ostheosynthesis under mobilization with full weight bearing. Patients and methods: 15 patients (14 female) with fragility fractures of the pelvis that required surgical stabilization were eligible to participate in this study from December 2012 to December 2014. Such details were documented and analysed as patient demographics, mechanism of injury, fracture classification, operative treatment and postoperative radiological parameters of achieved bone-implant interface. Results: The average age of the patients was 79.9 years (SD 9.0 years). According to Rommens five patients had a fragility fracture of the pelvis Type II-c, one a Type III-c, six a Type IV-b and three a Type IV-c. Four patients were treated by a cement augmented transiliac internal fixation (caTIFI). Seven patients received a cement augmented iliolumbar fixation. In all these patients the Schanz screws applied to the ilium were placed in an oblique dorsoventral direction into the supraacetabular bone canal (mean length of screws 100 +/- 20mm, max. 135mm, min. 70mm). Even though in four patients the iliosacral joint was hit tangential and one cortex perforation without any cement leakage appeared no revision surgery was necessary. Overall the clinical findings including mobilisation with full weight bearing showed a sufficient mechanically stability in all patients. Conclusion: The focus of this study was to describe the modified surgical technique of the caTIFI with placing the Schanz screws from the posterior superior iliac spine to the anterior inferior iliac spine into the supraacetabular bone canal. Usage of cannulated and perforated Schanz screws gives the opportunity to control the correct position of the screws before implanting them. Another advantage is that additional stability can be obtained by cement augmentation. We believe that the new technique of the caTIFI provides a greater intraoperative versatility and a greater mechanical stability for fragility fractures of the pelvis. (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:S114 / S120
页数:7
相关论文
共 19 条
  • [1] The minimally invasive stabilization of the dorsal pelvic ring with the transiliacal internal fixator (TIFI) -: Surgical technique and first clinical findings
    Füchtmeier, B
    Maghsudi, M
    Neumann, C
    Hente, R
    Roll, C
    Nerlich, M
    UNFALLCHIRURG, 2004, 107 (12): : 1142 - 1151
  • [2] Trochanteric fragility fractures Treatment using the cement-augmented proximal femoral nail antirotation
    Neuerburg, C.
    Mehaffey, S.
    Gosch, M.
    Boecker, W.
    Blauth, M.
    Kammerlander, C.
    OPERATIVE ORTHOPADIE UND TRAUMATOLOGIE, 2016, 28 (03): : 164 - 176
  • [3] Posterior stabilization of thoracic and lumbar spine fractures with the internal fixator - technique and results
    Pizanis, A
    Mutschler, W
    ZENTRALBLATT FUR CHIRURGIE, 1998, 123 (08): : 936 - 943
  • [4] Cement augmented percutaneous iliosacral screws prevent screw loosening in the treatment of patients with fragility fractures of the pelvis
    Haveman, Roelien
    Link, Bjorn-Christian
    Beeres, Frank J. P.
    Babst, Reto
    SWISS MEDICAL WEEKLY, 2018, 148 : 7S - 7S
  • [5] Combined vertebral stabilization by means of cement-augmented posterior instrumentation and balloon-kyphoplasty in osteoporotic burst fractures
    Blattert, T. R.
    Katscher, S.
    Glasmacher, S.
    Josten, C.
    CALCIFIED TISSUE INTERNATIONAL, 2007, 80 : S117 - S118
  • [6] Combined vertebral stabilization by means of cement-augmented posterior instrumentation and balloon-kyphoplasty in osteoporotic burst fractures.
    Blattert, T. R.
    Katscher, S.
    Glasmacher, S.
    Josten, C.
    JOURNAL OF BONE AND MINERAL RESEARCH, 2006, 21 : S420 - S420
  • [7] Treatment of Osteoporotic Compression Fractures at Thoracolumbar Spine With Neurodeficit: Short-Segment Stabilization With Cement-Augmented Fenestrated Pedicle Screws and Vertebroplasty by Minimally Invasive Percutaneous Technique
    Pawar, Abhijit
    Badhe, Vivek
    Gawande, Mohan
    INTERNATIONAL JOURNAL OF SPINE SURGERY, 2022, 16 (03): : 465 - 471
  • [8] Esthetic Positioning of Rigid Internal Fixation in Tripod Zygomatic Fractures: An Innovative Surgical Technique
    Becelli, Roberto
    Quarato, Davide
    Matarazzo, Giorgio
    Renzi, Giancarlo
    Dominici, Chiara
    JOURNAL OF CRANIOFACIAL SURGERY, 2009, 20 (03) : 724 - 725
  • [9] Osteoporotic L1 burst fracture treated by short-segment percutaneous stabilization with cement-augmented screws and kyphoplasty (hybrid technique)
    Pingel, Andreas
    Kandziora, Frank
    Hoffmann, Christoph-Heinrich
    EUROPEAN SPINE JOURNAL, 2014, 23 (09) : 2022 - 2023
  • [10] Osteoporotic L1 burst fracture treated by short-segment percutaneous stabilization with cement-augmented screws and kyphoplasty (hybrid technique)
    Andreas Pingel
    Frank Kandziora
    Christoph-Heinrich Hoffmann
    European Spine Journal, 2014, 23 : 2022 - 2023