Scaling calibration in region of interest reconstruction with the 1D and 2D ATRACT algorithm

被引:5
|
作者
Xia, Yan [1 ,2 ]
Dennerlein, Frank [3 ]
Bauer, Sebastian [3 ]
Hofmann, Hannes [1 ]
Hornegger, Joachim [1 ,2 ]
Maier, Andreas [1 ]
机构
[1] Univ Erlangen Nurnberg, Pattern Recognit Lab, D-91054 Erlangen, Germany
[2] Univ Erlangen Nurnberg, Grad Sch Adv Opt Technol SAOT, D-91054 Erlangen, Germany
[3] Siemens AG, Healthcare Sect, Erlangen, Germany
关键词
Region of interest imaging; Dose reduction; Truncation correction; Scaling calibration; FIELD-OF-VIEW; IMAGE-RECONSTRUCTION; HILBERT TRANSFORM; TOMOGRAPHY;
D O I
10.1007/s11548-014-0978-z
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Recently, a reconstruction algorithm for region of interest (ROI) imaging in C-arm CT was published, named Approximate Truncation Robust Algorithm for Computed Tomography (ATRACT). Even in the presence of substantial data truncation, the algorithm is able to reconstruct images without the use of explicit extrapolation or prior knowledge. However, the method suffers from a scaling and offset artifact in the reconstruction. Hence, the reconstruction results are not quantitative. It is our goal to reduce the scaling and offset artifact so that Hounsfield unit (HU) values can be used for diagnosis. In this paper, we investigate two variants of the ATRACT method and present the analytical derivations of these algorithms in the Fourier domain. Then, we propose an empirical correction measure that can be applied to the ATRACT algorithm, to effectively compensate the scaling and offset issue. The proposed method is evaluated on ten clinical datasets in the presence of different degrees of artificial truncation. With the proposed correction approach, we achieved an average relative root-mean-square error (rRMSE) of 2.81 % with respect to non-truncated Feldkamp, Davis, and Kress reconstruction, even for severely truncated data. The rRMSE is reduced to as little as 10 % of the image reconstructed without the scaling calibration. The reconstruction results show that ROI reconstruction of high accuracy can be achieved since the scaling and offset artifact are effectively eliminated by the proposed method. With this improvement, the HU values may be used for post-processing operations such as bone or soft tissue segmentation if some tolerance is accepted.
引用
收藏
页码:345 / 356
页数:12
相关论文
共 50 条
  • [1] Scaling calibration in region of interest reconstruction with the 1D and 2D ATRACT algorithm
    Yan Xia
    Frank Dennerlein
    Sebastian Bauer
    Hannes Hofmann
    Joachim Hornegger
    Andreas Maier
    [J]. International Journal of Computer Assisted Radiology and Surgery, 2014, 9 : 345 - 356
  • [2] Fast and accurate calibration of 1D and 2D gratings
    Lei, Lihua
    Liu, Yi
    Chen, Xin
    Fu, Yunxia
    Li, Yuan
    [J]. EQUIPMENT MANUFACTURING TECHNOLOGY AND AUTOMATION, PTS 1-3, 2011, 317-319 : 2196 - +
  • [3] A new algorithm for 2D region of interest tomography
    Van Gompel, G
    Tisson, G
    Van Dyck, D
    Sijbers, J
    [J]. MEDICAL IMAGING 2004: IMAGE PROCESSING, PTS 1-3, 2004, 5370 : 2105 - 2113
  • [4] A fast 2D image reconstruction algorithm from 1D data for the Gaia mission
    Harrison, Diana L.
    [J]. EXPERIMENTAL ASTRONOMY, 2011, 31 (2-3) : 157 - 175
  • [5] A fast 2D image reconstruction algorithm from 1D data for the Gaia mission
    Diana L. Harrison
    [J]. Experimental Astronomy, 2011, 31 : 157 - 175
  • [6] Calibration of a 1D/1D urban flood model using 1D/2D model results in the absence of field data
    Leandro, J.
    Djordjevic, S.
    Chen, A. S.
    Savic, D. A.
    Stanic, M.
    [J]. WATER SCIENCE AND TECHNOLOGY, 2011, 64 (05) : 1016 - 1024
  • [7] Region-Of-Interest Reconstruction on medical C-arms with the ATRACT Algorithm
    Dennerlein, Frank
    Maier, Andreas
    [J]. MEDICAL IMAGING 2012: PHYSICS OF MEDICAL IMAGING, 2012, 8313
  • [8] Calibration of 1D and 2D Fluvial Models with a Metamodel Based Optimization
    Benefice, Guillaume
    Duron, Luc
    Villanueva, Amaya
    Yang, Rui
    [J]. ADVANCES IN HYDROINFORMATICS: MODELS FOR COMPLEX AND GLOBAL WATER ISSUES-PRACTICES AND EXPECTATIONS, 2022, : 773 - 794
  • [9] Leakage reconstruction method for 2D/1D fusion transport calculations
    Liang, Liang
    Liu, Zhouyu
    Zheng, Youqi
    Cao, Liangzhi
    Wu, Hongchun
    [J]. PROGRESS IN NUCLEAR ENERGY, 2017, 97 : 60 - 73
  • [10] Robust Calibration Procedure of a Manipulator and a 2D Laser Scanner using a 1D Calibration Target
    Alberts, Jan
    Kleinschmidt, Sebastian P.
    Wagner, Bernardo
    [J]. ICINCO: PROCEEDINGS OF THE 16TH INTERNATIONAL CONFERENCE ON INFORMATICS IN CONTROL, AUTOMATION AND ROBOTICS, VOL 1, 2019, : 112 - 119