Analysis of SOFCs Using Reference Electrodes

被引:28
|
作者
Finklea, Harry [1 ]
Chen, Xiaoke [1 ]
Gerdes, Kirk [2 ]
Pakalapati, Suryanarayana [3 ]
Celik, Ismail [3 ]
机构
[1] W Virginia Univ, Bennett Dept Chem, Morgantown, WV 26506 USA
[2] Natl Energy Technol Lab, Morgantown, WV 26507 USA
[3] W Virginia Univ, Mech & Aerosp Engn Dept, Morgantown, WV 26506 USA
关键词
OXIDE FUEL-CELLS; ELECTROCHEMICAL IMPEDANCE SPECTROSCOPY; COMPOSITE CATHODES; EXPERIMENTAL LIMITATIONS; 3-POINT MEASUREMENTS; 3-ELECTRODE METHODS; SOLID ELECTROLYTES; CERMET ANODES; YSZ ANODE; POLARIZATION;
D O I
10.1149/2.093309jes
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
Reference electrodes are frequently applied to isolate the performance of one electrode in a solid oxide fuel cell. However, reference electrode simulations raise doubt to the veracity of data collected using reference electrodes. The simulations predict that the reported performance for the one electrode will frequently contain performance of both electrodes. Nonetheless, recent reports persistently treat data so collected as ideally isolated. This work confirms the predictions of the reference electrode simulations on two SOFC designs, and provides a method of validating the data measured in the 3-electrode configuration. Validation is based on the assumption that a change in gas composition to one electrode does not affect the impedance of the other electrode at open circuit voltage. This assumption is supported by a full physics simulation of the SOFC. Three configurations of reference electrode and cell design are experimentally examined using various gas flows and two temperatures. Impedance data are subjected to deconvolution analysis and equivalent circuit fitting and approximate polarization resistances of the cathode and anode are determined. The results demonstrate that the utility of reference electrodes is limited and often wholly inappropriate. Reported impedances and single electrode polarization values must be scrutinized on this basis. (C) 2013 The Electrochemical Society. All rights reserved.
引用
收藏
页码:F1055 / F1066
页数:12
相关论文
共 50 条
  • [1] On the diffusion in porous electrodes of SOFCs
    Kookos, Ioannis K.
    [J]. CHEMICAL ENGINEERING SCIENCE, 2012, 69 (01) : 571 - 577
  • [2] Theoretical Analysis of the Electrochemical Promotion of Infiltrations in MIEC Based Electrodes for IT-SOFCs
    Enrico, Anna
    Costamagna, Paola
    [J]. ICHEAP12: 12TH INTERNATIONAL CONFERENCE ON CHEMICAL & PROCESS ENGINEERING, 2015, 43 : 661 - 666
  • [3] Scandia-zirconia electrolytes and electrodes for SOFCS
    Irvine, JTS
    Politova, T
    Zakowsky, N
    Kruth, A
    Tao, S
    Travis, R
    Attia, O
    [J]. Fuel Cell Technologies: State and Perspectives, 2005, 202 : 35 - 47
  • [4] Structural and electrical characterisation of nanostructure electrodes for SOFCs
    Ahmad, Muhammad Ashfaq
    Akram, Nadeem
    Raza, Rizumm
    [J]. INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2014, 39 (30) : 17487 - 17491
  • [5] CP criteria using Zn reference electrodes
    不详
    [J]. MATERIALS PERFORMANCE, 1999, 38 (11) : 35 - 35
  • [6] Performance of metal-supported SOFCs with infiltrated electrodes
    Tucker, Michael C.
    Lau, Grace Y.
    Jacobson, Craig P.
    DeJonghe, Lutgard C.
    Visco, Steven J.
    [J]. JOURNAL OF POWER SOURCES, 2007, 171 (02) : 477 - 482
  • [7] Studies on Perovskite-Based Electrodes for Symmetrical SOFCs
    Dos Santos-Garcia, A. J.
    Ruiz-Morales, J. C.
    Canales-Vazquez, J.
    [J]. BOLETIN DE LA SOCIEDAD ESPANOLA DE CERAMICA Y VIDRIO, 2008, 47 (05): : 267 - 272
  • [8] REFERENCE ELECTRODES
    NEVELL, TG
    WALSH, FC
    [J]. TRANSACTIONS OF THE INSTITUTE OF METAL FINISHING, 1992, 70 : 144 - 147
  • [9] REFERENCE ELECTRODES
    ENGELHAR.J
    THACKER, R
    [J]. JOURNAL OF CHEMICAL EDUCATION, 1968, 45 (08) : 547 - &
  • [10] CHARACTERISTICS OF REFERENCE ELECTRODES USING A POLYMER GATE ISFET
    MATSUO, T
    NAKAJIMA, H
    [J]. SENSORS AND ACTUATORS, 1984, 5 (04): : 293 - 305