A FRET-based ratiometric fluorescent aptasensor for rapid and onsite visual detection of ochratoxin A

被引:53
|
作者
Qian, Jing [1 ]
Wang, Kan [1 ]
Wang, Chengquan [2 ]
Hua, Mengjuan [1 ]
Yang, Zhenting [1 ]
Liu, Qian [1 ]
Mao, Hanping [1 ]
Wang, Kun [1 ]
机构
[1] Jiangsu Univ, Sch Chem & Chem Engn, Key Lab Modern Agr Equipment & Technol, Zhenjiang 212013, Peoples R China
[2] Changzhou Coll Informat Technol, Changzhou 213164, Peoples R China
基金
中国国家自然科学基金; 中国博士后科学基金;
关键词
RESONANCE ENERGY-TRANSFER; REDUCED GRAPHENE OXIDE; LABEL-FREE DETECTION; QUANTUM DOTS; GOLD-NANOPARTICLES; ULTRASENSITIVE DETECTION; IMPEDIMETRIC APTASENSOR; SENSITIVE DETECTION; SELECTIVE DETECTION; APTAMER BIOSENSOR;
D O I
10.1039/c5an01403d
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A color change observable by the naked eye to indicate the content of an analyte is considered to be the most conceivable way of various sensing protocols. By taking advantage of the Forster resonance energy transfer (FRET) principles, we herein designed a dual-emission ratiometric fluorescent aptasensor for ochratoxin A (OTA) detection via a dual mode of fluorescent sensing and onsite visual screening. Amino group-modified OTA's aptamer was firstly labeled with the green-emitting CdTe quantum dots (gQDs) donor. The red-emitting CdTe QDs (rQDs) which were wrapped in the silica sphere could serve as the reference signal, while the gold nanoparticle (AuNP) acceptors were attached on the silica surface to bind with the thiolated complementary DNA (cDNA). The hybridization reaction between the aptamer and the cDNA brought gQD-AuNP pair close enough, thereby making the FRET occur in the aptasensor fabrication, while the subsequent fluorescence recovery induced by OTA was obtained in the detection procedure. Based on the red background of the wrapped rQDs, the aptasensor in response to increasing OTA displayed a distinguishable color change from red to yellow-green, which could be conveniently readout in solution even by the naked eye. Since the bioconjugations used as the aptasensor can be produced at large scale, this method can be used for in situ, rapid, or high-throughput OTA detection after only an incubation step in a homogeneous mode. We believe that this novel aptasensing strategy provides not only a promising method for OTA detection but also a universal model for detecting diverse targets by changing the corresponding aptamer.
引用
收藏
页码:7434 / 7442
页数:9
相关论文
共 50 条
  • [1] FRET-based fluorescent ratiometric probes for the rapid detection of endogenous hydrogen sulphide in living cells
    Zhang, Yuming
    Chen, Yuncong
    Bai, Yang
    Xue, Xuling
    He, Weijiang
    Guo, Zijian
    [J]. ANALYST, 2020, 145 (12) : 4233 - 4238
  • [2] FRET-based ratiometric fluorescent detection of arginine in mitochondrion with a hybrid nanoprobe
    Yueyue Li
    Yanan Ban
    Ruihui Wang
    Zheng Wang
    Zhanxian Li
    Chenjie Fang
    Mingming Yu
    [J]. Chinese Chemical Letters, 2020, 31 (02) : 443 - 446
  • [3] A FRET-based Ratiometric Fluorescent Probe for Nitroxyl Detection in Living Cells
    Zhang, Huatang
    Liu, Ruochuan
    Tan, Yi
    Xie, William Haowei
    Lei, Haipeng
    Cheung, Hon-Yeung
    Sun, Hongyan
    [J]. ACS APPLIED MATERIALS & INTERFACES, 2015, 7 (09) : 5438 - 5443
  • [4] FRET-based ratiometric fluorescent detection of arginine in mitochondrion with a hybrid nanoprobe
    Li, Yueyue
    Ban, Yanan
    Wang, Ruihui
    Wang, Zheng
    Li, Zhanxian
    Fang, Chenjie
    Yu, Mingming
    [J]. CHINESE CHEMICAL LETTERS, 2020, 31 (02) : 443 - 446
  • [5] Construction of a FRET-based ratiometric fluorescent thiol probe
    Long, Lingliang
    Lin, Weiying
    Chen, Bingbing
    Gao, Wensha
    Yuan, Lin
    [J]. CHEMICAL COMMUNICATIONS, 2011, 47 (03) : 893 - 895
  • [6] FRET-Based Aptasensor for the Selective and Sensitive Detection of Lysozyme
    Sapkota, Kumar
    Dhakal, Soma
    [J]. SENSORS, 2020, 20 (03)
  • [7] A FRET-based near-infrared ratiometric fluorescent probe for detection of mitochondria biothiol
    Wang, Lu
    Wang, Jianbo
    Xia, Shuai
    Wang, Xinxin
    Yu, Yating
    Zhou, Hongwei
    Liu, Haiying
    [J]. TALANTA, 2020, 219 (219)
  • [8] Ratiometric fluorescent aptasensor for convenient detection of ochratoxin A in beer and orange juice
    Yu, Jie
    Ai, Shuheng
    Zhang, Wenhan
    Wang, Chao
    Shi, Pengfei
    [J]. ANALYST, 2023, 148 (20) : 5172 - 5177
  • [9] A FRET-Based Near-Infrared Fluorescent Probe for Ratiometric Detection of Cysteine in Mitochondria
    Xia, Shuai
    Zhang, Yibin
    Fang, Mingxi
    Mikesell, Logan
    Steenwinkel, Tessa E.
    Wan, Shulin
    Phillips, Tyler
    Luck, Rudy L.
    Werner, Thomas
    Liu, Haiying
    [J]. CHEMBIOCHEM, 2019, 20 (15) : 1986 - 1994
  • [10] A novel FRET-based ratiometric fluorescent probe for highly sensitive detection of hydrogen sulfide
    Huang, Kunzhu
    Yu, Lun
    Xu, Pengfei
    Zhang, Xintong
    Zeng, Wenbin
    [J]. RSC ADVANCES, 2015, 5 (23): : 17797 - 17801