Analysis of shielding materials in a Compton spectrometer applied to X-ray tube quality control using Monte Carlo simulation

被引:5
|
作者
Gallardo, S
Ródenas, J
Verdú, G
Villaescusa, JI
机构
[1] Univ Politecn Valencia, Dept Ingn Quim & Nucl, E-46071 Valencia, Spain
[2] Univ Valencia, Hosp La Fe, Valencia 46015, Spain
关键词
D O I
10.1093/rpd/nci244
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
A realistic characterisation of the primary beam is very important for the quality control of X-ray tubes. The most accurate technique to assess the actual photon spectrum is X-ray spectrometry. Some difficulties arising in the spectrum determination can be avoided using a Compton spectrometer. Simulation models are useful tools to know the effect of some operational parameters, such as collimation of primary beam, relative position of focus and detector, and the influence of shielding materials. A simulation model has been developed using the MCNP code, based on the Monte Carlo method, in order to reproduce a commercial Compton spectrometer. In this work, the model developed is applied to analyse the influence on measurements of shielding materials present in the spectrometer.
引用
收藏
页码:375 / 379
页数:5
相关论文
共 50 条
  • [1] Monte Carlo simulation of the Compton scattering technique applied to characterize diagnostic x-ray spectra
    Gallardo, S
    Ródenas, J
    Verdú, G
    MEDICAL PHYSICS, 2004, 31 (07) : 2082 - 2090
  • [2] Monte Carlo simulation of x-ray tube spectra with PENELOPE
    Jia, Pengxiang
    Xie, Yaoqin
    Bao, Shanglian
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING, VOL 25, PT 2 - DIAGNOSTIC IMAGING, 2009, 25 : 503 - 506
  • [3] Monte Carlo simulation of a computed tomography x-ray tube
    Bazalova, Magdalena
    Verhaegen, Frank
    PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (19): : 5945 - 5955
  • [4] Monte Carlo simulation of photon buildup factors for shielding materials in diagnostic x-ray facilities
    Kharrati, Hedi
    Agrebi, Amel
    Karoui, Mohamed Karim
    MEDICAL PHYSICS, 2012, 39 (10) : 6014 - 6021
  • [5] Monte Carlo simulation of photon buildup factors for shielding materials in radiotherapy x-ray facilities
    Karoui, Mohamed Karim
    Kharrati, Hedi
    MEDICAL PHYSICS, 2013, 40 (07)
  • [6] Assessment of quality control parameters for an X-ray tube using the Monte Carlo method and unfolding techniques
    Gallardo, S.
    Rodenas, J.
    Verdu, G.
    Querol, A.
    2009 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-20, 2009, : 1367 - 1370
  • [7] Monte Carlo kilovoltage X-ray tube simulation: A statistical analysis and compact simulation method
    Bootsma, G. J.
    Nordstrom, H.
    Eriksson, M.
    Jaffray, D. A.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2020, 72 : 80 - 87
  • [8] Monte-Carlo simulation of a micro focal X-ray tube
    Tavora, LMN
    Morton, EJ
    1996 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1-3, 1997, : 783 - 787
  • [9] Material characterization and Monte Carlo simulation of lead and non-lead X-Ray shielding materials
    Aral, Nebahat
    Amor Duch, Maria
    Ardanuy, Monica
    RADIATION PHYSICS AND CHEMISTRY, 2020, 174
  • [10] Monte Carlo simulation of X-ray room shielding in diagnostic radiology using PHITS code
    Abdul Aziz, M. Z.
    Yani, S.
    Haryanto, F.
    Ya Ali, N. Kamarullah
    Tajudin, S. M.
    Iwase, H.
    Musarudin, M.
    JOURNAL OF RADIATION RESEARCH AND APPLIED SCIENCES, 2020, 13 (01) : 704 - 713