Haemodynamic performance of neuromuscular electrical stimulation (NMES) during recovery from total hip arthroplasty

被引:29
|
作者
Broderick, Barry J. [1 ,2 ]
Breathnach, Oisin [3 ]
Condon, Finbarr [3 ]
Masterson, Eric [3 ]
OLaighin, Gearoid [1 ,2 ]
机构
[1] NUI Galway, Sch Engn & Informat, Galway, Ireland
[2] NUI Galway, Natl Ctr Biomed Engn Sci, Bioelect Res Cluster, Galway, Ireland
[3] Midwestern Orthopaed Hosp, Dept Orthopaed, Croom, Limerick, Ireland
关键词
Neuromuscular electrical stimulation; NMES; Deep vein thrombosis; DVT; Total hip arthroplasty; Lower limb hemodynamics; VENOUS-BLOOD FLOW; LOWER-LIMB; COMPRESSION; PREVENTION; MUSCLE; THROMBOEMBOLISM; STASIS; DEVICE; PAIN;
D O I
10.1186/1749-799X-8-3
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Patients post total hip arthroplasty (THA) remain at high risk of developing Deep Vein Thrombosis (DVT) during the recovery period following surgery despite the availability of effective pharmacological and mechanical prophylactic methods. The use of calf muscle neuromuscular electrical stimulation (NMES) during the hospitalised recovery period on this patient group may be effective at preventing DVT. However, the haemodynamic effectiveness and comfort characteristics of NMES in post-THA patients immediately following surgery have yet to be established. Methods: The popliteal veins of 11 patients, who had undergone unilateral total hip replacement surgery on the day previous to the study, were measured using Doppler ultrasound during a 4 hour neuromuscular electrical stimulation (NMES) session of the calf muscles. The effect of calf muscle NMES on peak venous velocity, mean venous velocity and volume flow were compared to resting values. Comfort was assessed using a 100mm non-hatched visual analogue scale taken before application of NMES, once NMES was initiated and before NMES was withdrawn. Results: In the operated limb NMES produced increases in peak venous velocity of 99% compared to resting. Mean velocity increased by 178% compared to resting and volume flow increased by 159% compared to resting. In the un-operated limb, peak venous velocity increased by 288%, mean velocity increased by 354% and volume flow increased by 614% compared to basal flow (p<0.05 in all cases). There were no significant differences observed between the VAS scores taken before the application of NMES, once NMES was initiated and before NMES was withdrawn (p=.211). Conclusions: NMES produces a beneficial hemodynamic response in patients in the early post-operative period following orthopaedic surgery. This patient group found extended periods of calf-muscle NMES tolerable.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Haemodynamic performance of neuromuscular electrical stimulation (NMES) during recovery from total hip arthroplasty
    Barry J Broderick
    Oisin Breathnach
    Finbarr Condon
    Eric Masterson
    Gearóid ÓLaighin
    Journal of Orthopaedic Surgery and Research, 8
  • [2] The use of neuromuscular electrical stimulation (NMES) in the early recovery period following Total Hip Arthroplasty to enhance lower limb haemodynamics
    Breathnach, O.
    Broderick, B.
    Laighin, G. O.
    Condon, F.
    Masterson, E.
    IRISH JOURNAL OF MEDICAL SCIENCE, 2011, 180 : S100 - S100
  • [3] Cardiopulmonary and haemodynamic changes during total hip arthroplasty
    L. López-Durán
    A. García-López
    L. Durán
    J. Hurtado
    C. Ruiz
    J. L. Rodrigo
    International Orthopaedics, 1997, 21 : 253 - 258
  • [4] Cardiopulmonary and haemodynamic changes during total hip arthroplasty
    LopezDuran, L
    GarciaLopez, A
    Duran, L
    Hurtado, J
    Ruiz, C
    Rodrigo, JL
    INTERNATIONAL ORTHOPAEDICS, 1997, 21 (04) : 253 - 258
  • [5] Neuromuscular Electrical Stimulation (NMES) and α-Lipoic Acid
    Beutner, Franz-Ulrich
    DEUTSCHES ARZTEBLATT INTERNATIONAL, 2019, 116 (38): : 643 - 643
  • [6] Neuromuscular Electrical Stimulation (NMES) In Patients With COPD During An Exacerbation (ECOPD)
    Giavedoni, S.
    MacNee, W.
    Rabinovich, R. A.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2010, 181
  • [7] Changes in microvascular oxygenation and total hemoglobin concentration of the vastus lateralis during neuromuscular electrical stimulation (NMES)
    Bellew, James W.
    Cayot, Trent
    Brown, Karisa
    Blair, Crystal
    Dishion, Tommy
    Ortman, Brett
    Reel, Alex
    PHYSIOTHERAPY THEORY AND PRACTICE, 2021, 37 (08) : 926 - 934
  • [8] Neuromuscular electrical stimulation (NMES) for patellofemoral pain syndrome
    Martimbianco, Ana Luiza C.
    Torloni, Maria Regina
    Andriolo, Brenda N. G.
    Porfirio, Gustavo J. M.
    Riera, Rachel
    COCHRANE DATABASE OF SYSTEMATIC REVIEWS, 2017, (12):
  • [9] A Randomized, Double-Blind, Placebo-Controlled Study of Neuromuscular Electrical Stimulation (NMES) use for Recovery after Elective Total Hip Replacement Surgery
    Castellano, Jerome J.
    Rojas, Ana-Marie
    Karia, Raj
    Hunter, Tracey
    Slover, James
    Moroz, Alex
    BULLETIN OF THE HOSPITAL FOR JOINT DISEASES, 2016, 74 (04): : 275 - 281
  • [10] Textile Electrodes: Influence of Electrode Construction and Pressure on Stimulation Performance in Neuromuscular Electrical Stimulation (NMES)
    Euler, Luisa
    Juthberg, Robin
    Flodin, Johanna
    Guo, Li
    Ackermann, Paul W.
    Persson, Nils-Krister
    2021 43RD ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE & BIOLOGY SOCIETY (EMBC), 2021, : 1305 - 1308