Fire behaviour of thin-walled steel tube confined reinforced concrete stub columns under axial compression

被引:12
|
作者
Zhang, Ruizhi [1 ,2 ]
Liu, Jiepeng [1 ,3 ]
Wang, Weiyong [1 ,3 ]
Chen, Y. Frank [1 ,3 ]
机构
[1] Chongqing Univ, Sch Civil Engn, Chongqing 400045, Peoples R China
[2] Imperial Coll London, Dept Civil & Environm Engn, London SW7 2AZ, England
[3] Chongqing Univ, Minist Educ, Key Lab New Technol Construct Cities Mt Area, Chongqing 400045, Peoples R China
基金
中国国家自然科学基金;
关键词
Thin-walled steel tube confined concrete columns; Fire tests; Finite element modelling; Parametric studies; Fire resistance; Design approach; POSTFIRE BEHAVIOR; RESISTANCE; MODEL; STRENGTH; DESIGN;
D O I
10.1016/j.jcsr.2020.106180
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Thin-walled steel tube confined reinforced concrete columns are new-type composite members and the static and seismic performance of these columns have been extensively investigated in recent decades. There are, however, very limited studies on the fire behaviour of the steel tube confined reinforced concrete stub columns subjected to axial compression. In this paper, experimental and numerical studies on the fire response of steel tube confined reinforced concrete stub columns under axial compression are presented. A total of eight specimens with varying wall thicknesses of steel tube and load ratios were tested to failure under the ISO-834 standard fire. Temperature distribution, axial deformation, failure modes, and fire duration were recorded in the fire tests. Finite element (FE) models were established using ABAQUS to estimate the fire behaviour and the models were validated by comparing with the measured results. Parametric studies were then performed on the fire resistance of thin-walled steel tube confined reinforced concrete stub columns and the considered parameters include diameter of steel tube, wall thickness of steel tube, load ratio, reinforcement ratio, material strength, and concrete cover thickness. The studies show that the load ratio and diameter of steel tube are two key factors governing fire resistance of thin-walled steel tube confined reinforced concrete stub columns. Based on test and numerical results, a design approach was proposed to predict the temperature distribution and loading capacity of thin-walled steel tube confined reinforced concrete stub columns under ISO-834 standard fire. (c) 2020 Elsevier Ltd. All rights reserved.
引用
收藏
页数:16
相关论文
共 50 条
  • [1] Behavior of circular thin-walled steel tube confined concrete stub columns
    Ding, Fa-xing
    Tan, Liu
    Liu, Xue-mei
    Wang, Liping
    [J]. STEEL AND COMPOSITE STRUCTURES, 2017, 23 (02): : 229 - 238
  • [2] Behavior of thin walled steel tube confined concrete stub columns subjected to axial local compression
    Han, Lin-Hai
    Liu, Wei
    Yang, You-Fu
    [J]. THIN-WALLED STRUCTURES, 2008, 46 (02) : 155 - 164
  • [3] Axial compressive performances of thin-walled steel tube confined steel-reinforced concrete columns after fire exposure
    Wang, Fengqin
    Liu, Faqi
    Yang, Hua
    Sheng, Honghe
    [J]. THIN-WALLED STRUCTURES, 2023, 190
  • [4] Analysis and Design of Elliptical Concrete-Filled Thin-Walled Steel Stub Columns Under Axial Compression
    Jingfeng Wang
    Qihan Shen
    Han Jiang
    Xuebei Pan
    [J]. International Journal of Steel Structures, 2018, 18 : 365 - 380
  • [5] Analysis and Design of Elliptical Concrete-Filled Thin-Walled Steel Stub Columns Under Axial Compression
    Wang, Jingfeng
    Shen, Qihan
    Jiang, Han
    Pan, Xuebei
    [J]. INTERNATIONAL JOURNAL OF STEEL STRUCTURES, 2018, 18 (02) : 365 - 380
  • [6] Experimental Research of FRP Composite Tube Confined Steel-reinforced Concrete Stub Columns Under Axial Compression
    Wang, Ji Zhong
    Cheng, Lu
    Wang, Xin Pei
    [J]. 2018 4TH INTERNATIONAL CONFERENCE ON ENERGY MATERIALS AND ENVIRONMENT ENGINEERING (ICEMEE 2018), 2018, 38
  • [7] Axial compression behaviour of CFRP confined reactive power concrete filled steel tube stub columns
    Jiao, Chujie
    Li, Song
    Cui, Lishi
    Wang, Zhiren
    Jian, Chao
    [J]. Fuhe Cailiao Xuebao/Acta Materiae Compositae Sinica, 2021, 38 (02): : 439 - 448
  • [8] Axial compression performance of thin-walled concrete-filled square steel tube short columns confined by stirrup
    Chen, Jun
    Ni, Jia-Gui
    Liu, Zhe
    Ma, Wen-Bo
    Deng, Xu-Hua
    [J]. Jilin Daxue Xuebao (Gongxueban)/Journal of Jilin University (Engineering and Technology Edition), 2023, 53 (01): : 170 - 177
  • [9] Eccentric compression performance of concrete columns after fire and strengthened with thin-walled steel tube
    Xu, Yuye
    Guo, Luhao
    Ni, Yanping
    Luo, Yi
    [J]. Jianzhu Jiegou Xuebao/Journal of Building Structures, 2020, 41 (08): : 143 - 153
  • [10] Axial compressive behaviour of stainless steel tube-confined steel-reinforced recycled concrete stub columns
    Zheng, Yongqian
    He, Duoyi
    Yan, Guiyun
    Mbanda, Erneste
    [J]. JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2022, 199