A 3D Index (ΔX3D) for Evaluating Image Quality of Stereoscopic Displays

被引:1
|
作者
Chang, Yu-Cheng [1 ,2 ]
Chien, Yu-Yi [1 ,2 ]
Huang, Yi-Pai [1 ,2 ]
机构
[1] Natl Chiao Tung Univ, Dept Photon, Hsinchu 300, Taiwan
[2] Natl Chiao Tung Univ, Inst Electroopt Engn, Hsinchu 300, Taiwan
来源
JOURNAL OF DISPLAY TECHNOLOGY | 2015年 / 11卷 / 10期
关键词
Crosstalk; disparity; human factor experiment; image evaluation; motion blur; 3D image index; LIQUID-CRYSTAL LENS; CROSSTALK;
D O I
10.1109/JDT.2015.2433302
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In stereoscopic displays, crosstalk is typically observed when the views for both eyes are not clearly separated. Crosstalk affects the quality of 3D images and can cause visual fatigue in observers. According to the results of perception experimentation, different visual depth (disparity) and motion blur can also affect the perception of 3D image quality. Therefore, considering the effects of crosstalk, disparity, and motion blur, we propose an evaluation index to quantify 3D image performance for stereoscopic displays. This index assesses the optical quality of a 3D display as well as the effects of image content. According to human vision experimentation, the 3D image index (Delta X-3D) is validated to have a high positive correlation (0.8) with human perception. After combining the human visual mechanism and Delta X-3D, the proposed index can represent the visual quality of static and dynamic images on stereoscopic displays.
引用
收藏
页码:814 / 820
页数:7
相关论文
共 50 条
  • [1] Stereoscopic reconfiguration for 3D displays
    Houde, Jean-Christophe
    Jodoin, Pierre-Marc
    Deschenes, Francois
    [J]. STEREOSCOPIC DISPLAYS AND APPLICATIONS XXIII, 2012, 8288
  • [2] Assessment and improvement of the stereo-image visualization on X3D technologies 3D-displays
    Relke, I
    Klippstein, M
    Riemann, B
    [J]. STEREOSCOPIC DISPLAYS AND VIRTUAL REALITY SYSTEMS XI, 2004, 5291 : 204 - 211
  • [3] X3D: Extensible 3D graphics standard
    Daly, Leonard
    Brutzman, Don
    [J]. IEEE SIGNAL PROCESSING MAGAZINE, 2007, 24 (06) : 130 - 135
  • [4] A Guide to Stereoscopic 3D Displays in Medicine
    Held, Robert T.
    Hui, Tiffany T.
    [J]. ACADEMIC RADIOLOGY, 2011, 18 (08) : 1035 - 1048
  • [5] Stereoscopic 3D image stylization
    Northam, Lesley
    Asente, Paul
    Kaplan, Craig S.
    [J]. COMPUTERS & GRAPHICS-UK, 2013, 37 (05): : 389 - 402
  • [6] 3D PERCEPTION BASED QUALITY POOLING ON STEREOSCOPIC IMAGE
    Kim, Haksub
    Kim, Junghwan
    Lee, Sanghoon
    [J]. 2015 IEEE INTERNATIONAL CONFERENCE ON IMAGE PROCESSING (ICIP), 2015, : 3382 - 3386
  • [7] Quality assessment of stereoscopic image by 3D structural similarity
    Kenny H. B. Voo
    David B. L. Bong
    [J]. Multimedia Tools and Applications, 2018, 77 : 2313 - 2332
  • [8] Quality assessment of stereoscopic image by 3D structural similarity
    Voo, Kenny H. B.
    Bong, David B. L.
    [J]. MULTIMEDIA TOOLS AND APPLICATIONS, 2018, 77 (02) : 2313 - 2332
  • [9] What is 3D Good For? A Review of Human Performance on Stereoscopic 3D Displays
    McIntire, John P.
    Havig, Paul R.
    Geiselman, Eric E.
    [J]. HEAD- AND HELMET-MOUNTED DISPLAYS XVII AND DISPLAY TECHNOLOGIES AND APPLICATIONS FOR DEFENSE, SECURITY, AND AVIONICS VI, 2012, 8383
  • [10] X3D web service using 3D image mosaicing and location-based image indexing
    Chon, Jaechoon
    Lee, Yang-Won
    Fuse, Takashi
    [J]. MULTIMEDIA CONTENT REPRESENTATION, CLASSIFICATION AND SECURITY, 2006, 4105 : 658 - 666