Monitoring of On-site Generated Hypochlorite for Water Disinfection

被引:1
|
作者
Denis, Jean-Martin [1 ]
Donze, Gerard [2 ]
Willen, Stefan [1 ]
Darioly, Madeleine [1 ]
Andlauer, Wilfried [1 ]
Piantini, Umberto [1 ]
机构
[1] HES SO Valais, Inst Life Technol, Sch Engn, CH-1950 Sion, Switzerland
[2] Swiss Fed Off Publ Hlth FOPH, Bern, Switzerland
关键词
Chlorate; Disinfection by-products; On-site hypochlorite generation; Swimming pool; Water; CHLORATE; BROMATE; PERCHLORATE;
D O I
10.2533/chimia.2022.871
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
The aim of this study was to better evaluate the impact of on-site electro-generated hypochlorite for water disinfection. For this venture, the daily variability of hypochlorite-generating systems and their performance to produce low disinfection by-products during the formation of hypochlorite were observed. Seven on site electro-generated hypochlorite installations were selected at different swimming pools facilities in Switzerland. Active chlorine (AC), the two disinfection by-products chlorate (ClO3-) and perchlorate (ClO4-), and the pH were monitored over several hours. All monitored installations produced significant concentrations of chlorate, related to the measured active chlorine concentration. The median chlorate concentrations ranged between 1.4 to 76.9 mu g ClO3-/mg AC during daily monitoring. Perchlorates have been detected only in the installations of one brand that generated concentrations up to 34.9 mu g ClO4-/mg AC. For all installations, pH was lower than expected with a median pH of 9.6. Some samples presented even surprisingly acidic pH leading to possible sample degradation. This study clearly shows the weakness of a one-shot sampling to evaluate the quality of on-site electro-generated hypochlorite systems, due to high daily process variations. Additionally, the evaluation of the influence of three process parameters has pointed out that including chlorate aspects during the optimisation stage of on-site generated hypochlorite may significantly reduce chlorate contamination during water disinfection.
引用
收藏
页码:871 / 875
页数:5
相关论文
共 50 条
  • [1] A safe option for disinfection: On-site sodium hypochlorite generation
    Ainsworth, L
    Hampton, J
    [J]. WATER-ENGINEERING & MANAGEMENT, 1997, 144 (12): : 25 - 27
  • [3] ON-SITE hypochlorite generation
    Garibi, Alberto
    Kazanowski, Leo A.
    [J]. Pollution Engineering, 2006, 38 (06) : 32 - 35
  • [4] ON-SITE HYPOCHLORITE GENERATION.
    Kuhn, Anselm
    [J]. Processing, 1975, 21 (03): : 6 - 7
  • [5] ON-SITE HYPOCHLORITE GENERATION.
    Kuhn, Anslem
    [J]. Processing, 1975, 21 (04): : 10 - 12
  • [6] A Plasma Spectroscopic Microdevice for on-Site Water Monitoring
    Sweeney, John
    Whitney, Chad
    Wilson, Chester G.
    [J]. 2009 IEEE SENSORS, VOLS 1-3, 2009, : 2005 - 2008
  • [7] Maintenance strategies for on-site water disinfection by ultraviolet lamps on dairy farms
    Masse, Daniel I.
    Masse, Lucie
    Topp, Edward
    Seguin, Guy
    Ortega, Lina M.
    Scott, Andrew
    Pariseau, Eric
    [J]. WATER QUALITY RESEARCH JOURNAL OF CANADA, 2011, 46 (01): : 2 - 12
  • [8] Water Quality Assessment Tool for On-Site Water Quality Monitoring
    Olatinwo, Segun O.
    Joubert, Trudi-H.
    [J]. IEEE SENSORS JOURNAL, 2024, 24 (10) : 16450 - 16466
  • [9] Arizona Utility Expands On-Site Hypochlorite Generation
    Andrews, Robert
    [J]. Opflow, 2020, 46 (01): : 22 - 23
  • [10] An electrophoretic ion analyzer for on-site autonomous water monitoring
    Liu, Shuai
    Pan, Zhen
    Liang, Ying
    Li, Feng
    Breadmore, Michael C.
    Zhang, Min
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2021, 1637