Monte Carlo Simulations of the GE Discovery Alcyone CZT SPECT system

被引:0
|
作者
Ljungberg, Michael [1 ]
Liu, Chi [2 ]
Fan, Peng [2 ]
Pretorius, P. Hendrik [3 ]
机构
[1] Lund Univ, Dept Med Radiat Phys, Lund, Sweden
[2] Yale Univ, Diagnost Radiol, New Haven, CT 06520 USA
[3] Univ Massachusetts, Dept Radiol, Worcester, MA 01605 USA
关键词
Charge; CZT; Montre Carlo; Simulation; SPECT;
D O I
暂无
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Compact SPECT systems with cadmium zinc telluride (CZT) solid-state detectors with improved energy resolution and shorter acquisition times have recently been introduced. These systems have, however, different energy characteristics compared to NaI(Tl) crystal-based cameras; therefore, a need exists to develop new simulation models for these cameras. We modeled the charge transport within the CZT detectors for a GE Discovery 530c/570c SPECT system with multiple pinhole collimators employing the SIMIND Monte Carlo program and validated simulations against measurements. The incomplete charge collection between the anode and cathode in the pixilated CZT was modeled with the Hecht equation. The simulation also included charge-sharing effects across pixels due to physical interactions and charge diffusion. To validate our CZT-model, Tc-99m and I-123 point sources and a 201Tl line source were acquired and measured. Measured energy spectra were compared with simulated energy spectra. The Monte Carlo simulated energy spectra agreed well with the experimental measurements within the photopeak, overestimated the k-edge x-ray escape peaks of cadmium and telluride, and slightly underestimated the remainder of the tail. Comparisons of system sensitivity and spatial resolution were also conducted for an array of point source locations with results showing excellent agreement. Lastly, to demonstrate a clinically realistic case, a simulation of an anthropomorphic phantom with a cardiac insert and an inferior defect was performed. Simulated projections were processed using the GE Xeleris software confirming the accuracy of the SIMIND geometry. We conclude that it is feasible to simulate the GE Discovery 530c/570c SPECT system using the SIMIND code.
引用
收藏
页数:3
相关论文
共 50 条
  • [1] Monte Carlo Simulations of the GE Discovery Alcyone CZT SPECT Systems
    Pretorius, P. Hendrik
    Liu, Chi
    Fan, Peng
    Peterson, Mikael
    Ljungberg, Michael
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2015, 62 (03) : 832 - 839
  • [2] Monte Carlo simulations of the SNM spectra for CZT and NaI spectrometers
    Chen, Liang
    Wei, Yi-Xiang
    [J]. APPLIED RADIATION AND ISOTOPES, 2008, 66 (08) : 1146 - 1150
  • [3] Monte Carlo simulation of CZT-based cardiac SPECT systems
    Liu, Zemei
    Ljungberg, Michael
    Chan, Chung
    Liu, Chi
    Holstensson, Maria
    Hutton, Brian
    Pretorius, P.
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2012, 53
  • [4] Validation of GATE Monte Carlo simulations of the GE Advance/Discovery LS PET scanners
    Schmidtlein, CR
    Kirov, AS
    Nehmeh, SA
    Erdi, YE
    Humm, JL
    Amols, HI
    Bidaut, LM
    Ganin, A
    Stearns, CW
    McDaniel, DL
    Hamacher, KA
    [J]. MEDICAL PHYSICS, 2006, 33 (01) : 198 - 208
  • [5] Monte Carlo simulations of sodium iodide detector modules for a cylindrical SPECT system
    Ordonez, CE
    Chang, W
    [J]. 1995 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD, VOLS 1-3, 1996, : 1548 - 1552
  • [6] Experimental evaluation of the GE Discovery 870 CZT clinical SPECT system equipped with WEHR and MEHRS collimator
    Ito, Toshimune
    Matsusaka, Yohji
    Onoguchi, Masahisa
    Ichikawa, Hajime
    Okuda, Koichi
    Shibutani, Takayuki
    Shishido, Masaaki
    Sato, Kozo
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2021, 22 (02): : 165 - 177
  • [7] Accelerated GPU based SPECT Monte Carlo simulations
    Garcia, Marie-Paule
    Bert, Julien
    Benoit, Didier
    Bardies, Manuel
    Visvikis, Dimitris
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (11): : 4001 - 4018
  • [8] Towards a comprehensive validation for Monte Carlo SPECT simulations
    Pells, S.
    Cullen, D. M.
    Robinson, A. P.
    Pietras, B.
    Deidda, D.
    Fenwick, A.
    Ferreira, K.
    Fish, A.
    Hamilton, D.
    Heetun, W.
    Julyan, P.
    Needham, G.
    Page, E.
    Price, E.
    Tipping, J.
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2021, 48 (SUPPL 1) : S261 - S261
  • [9] Characterisation of Scatter and Attenuation in GE Discovery 530c using Monte Carlo simulations
    Peterson, M.
    Ljungberg, M.
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2016, 43 : S93 - S93
  • [10] Optimization of detection geometry for industrial SPECT by Monte Carlo simulations
    Park, J. G.
    Kim, C. H.
    Han, M. C.
    Jung, S. H.
    Kim, J. B.
    Moon, J.
    [J]. JOURNAL OF INSTRUMENTATION, 2013, 8