Reproducibility of Apparent Diffusion Coefficient Measurements in Malignant Breast Masses

被引:9
|
作者
Jang, Mijung [1 ]
Kim, Sun Mi [1 ]
Yun, Bo La [1 ]
Ahn, Hye Shin [2 ]
Kim, Soo Yeon [3 ]
Kang, Eunyoung [4 ]
Kim, Sung-Won [5 ]
机构
[1] Seoul Natl Univ, Bundang Hosp, Dept Radiol, Songnam 13620, South Korea
[2] Chung Ang Univ Hosp, Dept Radiol, Seoul, South Korea
[3] Hanyang Univ, Guri Hosp, Dept Radiol, Guri, South Korea
[4] Seoul Natl Univ, Bundang Hosp, Dept Surg, Songnam, South Korea
[5] Daerim St Marys Hosp, Breast Care Ctr, Dept Surg, Seoul, South Korea
基金
新加坡国家研究基金会;
关键词
Magnetic Resonance; Apparent Diffusion Coefficient; Diffusion Magnetic Resonance Imaging; Reproducibility; Breast; Neoplasms; WEIGHTED MRI; CANCER; LESIONS; VALUES; ONCOLOGY; TUMORS;
D O I
10.3346/jkms.2015.30.11.1689
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
This study aimed to evaluate the reproducibility of apparent diffusion coefficient (ADC) measurements in malignant breast masses, and to determine the influence of mammographic parenchymal density on this reproducibility. Sixty-six patients with magnetic resonance findings of the mass were included. Two breast radiologists measured the ADC of the malignant breast mass and the same area on the contralateral normal breast in each patient twice. The effects of mammographic parenchymal density, histology, and lesion size on reproducibility were also assessed. There was no significant difference in the mean ADC between repeated measurements in malignant breast masses and normal breast tissue. The overall reproducibility of ADC measurements was good in both. The 95% limits of agreement for repeated ADCs were approximately 30.2%-33.4% of the mean. ADC measurements in malignant breast masses were highly reproducible irrespective of mass size, histologic subtype, or coexistence of microcalcifications; however, the measurements tended to be less reproducible in malignant breast masses with extremely dense parenchymal backgrounds. ADC measurements in malignant breast masses are highly reproducible; however, mammographic parenchymal density can potentially influence this reproducibility.
引用
收藏
页码:1689 / 1697
页数:9
相关论文
共 50 条
  • [1] Apparent diffusion coefficient measurements in the differentiation between benign and malignant neck masses
    Salem, Faten
    Elshafey, Rasha
    Elmahalawy, Mohamed
    Elshaeny, Seham
    EGYPTIAN JOURNAL OF RADIOLOGY AND NUCLEAR MEDICINE, 2014, 45 (02): : 367 - 375
  • [2] Reproducibility of apparent diffusion coefficient measurements evaluated with different workstations
    Fanariotis, M.
    Vassiou, K.
    Tsougos, I.
    Fezoulidis, I.
    CLINICAL RADIOLOGY, 2018, 73 (02) : 141 - 148
  • [3] Apparent diffusion coefficient in differentiation between malignant and benign breast masses: does size matter?
    Wan, C. W. S.
    Lee, C. Y.
    Lui, C. Y.
    Fong, C. Y.
    Lau, K. C. H.
    CLINICAL RADIOLOGY, 2016, 71 (02) : 170 - 177
  • [4] The utility of diffusion weighted MRI and apparent diffusion coefficient in characterization of breast masses
    Wahab, Moustafa A. Kader A.
    Kareem, Hoda Abdel
    Hassan, Ebtesam Esmail
    EGYPTIAN JOURNAL OF RADIOLOGY AND NUCLEAR MEDICINE, 2015, 46 (04): : 1257 - 1265
  • [5] Diffusion weighted imaging of the normal breast: reproducibility of apparent diffusion coefficient measurements and variation with menstrual cycle and menopausal status
    Elizabeth A. M. O’Flynn
    Veronica A. Morgan
    Sharon L. Giles
    Nandita M. deSouza
    European Radiology, 2012, 22 : 1512 - 1518
  • [6] Diffusion weighted imaging of the normal breast: reproducibility of apparent diffusion coefficient measurements and variation with menstrual cycle and menopausal status
    O'Flynn, Elizabeth A. M.
    Morgan, Veronica A.
    Giles, Sharon L.
    deSouza, Nandita M.
    EUROPEAN RADIOLOGY, 2012, 22 (07) : 1512 - 1518
  • [7] Four Different Apparent Diffusion Coefficient Measurement Methods in Breast Masses
    Duran, Betul
    Ucpinar, Burcin Agridag
    JCPSP-JOURNAL OF THE COLLEGE OF PHYSICIANS AND SURGEONS PAKISTAN, 2021, 31 (09): : 1024 - 1029
  • [8] Apparent Diffusion Coefficient Reproducibility Across 3 T Scanners in a Breast Diffusion Phantom
    Fang, Lauren K.
    Keenan, Kathryn E.
    Carl, Michael
    Ojeda-Fournier, Haydee
    Rodriguez-Soto, Ana E.
    Rakow-Penner, Rebecca A.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2023, 57 (03) : 812 - 823
  • [9] Value of apparent diffusion coefficient measurement for discrimination of focal benign and malignant hepatic masses
    Kilickesmez, O.
    Bayramoglu, S.
    Inci, E.
    Cimilli, T.
    JOURNAL OF MEDICAL IMAGING AND RADIATION ONCOLOGY, 2009, 53 (01) : 50 - 55
  • [10] Diffusion-Weighted Breast Magnetic Resonance Imaging: A Semiautomated Voxel Selection Technique Improves Interreader Reproducibility of Apparent Diffusion Coefficient Measurements
    Rahbar, Habib
    Kurland, Brenda F.
    Olson, Matthew L.
    Kitsch, Averi E.
    Scheel, John R.
    Chai, Xiaoyu
    Usoro, Joshua
    Lehman, Constance D.
    Partridge, Savannah C.
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2016, 40 (03) : 428 - 435