Epidural ropivacaine for the initiation of labor epidural analgesia: A dose finding study

被引:27
|
作者
Beilin, Y
Galea, M
Zahn, J
Bodian, CA
机构
[1] CUNY Mt Sinai Sch Med, Dept Anesthesiol, New York, NY 10029 USA
[2] CUNY Mt Sinai Sch Med, Dept Obstet Gynecol & Reprod Sci, New York, NY 10029 USA
[3] CUNY Mt Sinai Sch Med, Dept Biomath Sci, New York, NY 10029 USA
来源
ANESTHESIA AND ANALGESIA | 1999年 / 88卷 / 06期
关键词
D O I
10.1097/00000539-199906000-00027
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
The purpose of our study was to determine the lowest concentration of ropivacaine that offers pain relief for the initiation of labor epidural analgesia. Women in active labor were enrolled in this prospective, randomized, double-blinded study to receive either ropivacaine 0.20% (Group I), ropivacaine 0.15% (Group II), or ropivacaine 0.10% (Group III). After placement of the epidural catheter, 13 mL of the study medication was administered. Fifteen minutes later, the adequacy of analgesia was assessed. If the woman reported that her degree of analgesia was not adequate, an additional 5 mL of the study medication was given, the degree of pain relief was reassessed 15 min later, and the study was concluded. A sequential study design was used to assess the success rates. We found that 26 of 28 (93%) women in Group I had adequate analgesia, compared with only 18 of 28 (64%) in Group II (P = 0.014) and 4 of 12 (33%) in Group III(P = 0.003). We conclude that rogivacaine 0.20% offers adequate analgesia significantly more often than either ropivacaine 0.15% or ropivacaine 0.10%. If one selects ropivacaine as the sole local anesthetic for the initiation of labor epidural analgesia, the minimal concentration should be 0.20%. Implications: The lowest effective concentration of ropivacaine for the initiation of labor epidural analgesia has not been determined. We found that ropivacaine 0.20% offers adequate analgesia significantly more often than either ropivacaine 0.15% or ropivacaine 0.10%. If one selects ropivacaine as the sole local anesthetic for the initiation of labor epidural analgesia, the minimal concentration should be 0.20%.
引用
收藏
页码:1340 / 1345
页数:6
相关论文
共 50 条
  • [1] Low-dose ropivacaine for initiation of epidural labor analgesia
    Palmer, CM
    Van Maren, G
    Nogami, W
    Alves, D
    ANESTHESIOLOGY, 1998,
  • [2] Dose-response study of epidural ropivacaine for labor analgesia
    Lee, BB
    Kee, WDN
    Wong, ELY
    Liu, JYW
    ANESTHESIOLOGY, 2001, 94 (05) : 767 - 772
  • [3] Optimal Dose of Epidural Dexmedetomidine Added to Ropivacaine for Epidural Labor Analgesia: A Pilot Study
    Zhang Wangping
    Ren Ming
    EVIDENCE-BASED COMPLEMENTARY AND ALTERNATIVE MEDICINE, 2017, 2017
  • [4] Are lower concentrations of ropivacaine effective for initiation of epidural labor analgesia?
    Palmer, CM
    Nogami, WM
    Alves, D
    ANESTHESIOLOGY, 2000, 93 (3A) : U215 - U215
  • [5] Effect of ropivacaine and sufentanil in epidural labor analgesia
    Wen, Xijiao
    Huang, Bowan
    Liang, Xin
    AMERICAN JOURNAL OF TRANSLATIONAL RESEARCH, 2021, 13 (06): : 7001 - 7007
  • [6] Circadian Variation in the Median Effective Dose of Epidural Ropivacaine for Labor Analgesia
    Deng, Jiali
    Wei, Changna
    Liu, Lin
    Qian, Jing
    Xiao, Fei
    Chen, Xinzhong
    FRONTIERS IN MEDICINE, 2021, 8
  • [7] Ropivacaine Versus Bupivacaine for Epidural Labor Analgesia
    Beilin, Yaakov
    Halpern, Stephen
    ANESTHESIA AND ANALGESIA, 2010, 111 (02): : 482 - 487
  • [8] Improving ropivacaine 0.1% epidural labor analgesia
    Bonnemere, V
    Brichant, JF
    Dewandre, PY
    Hans, P
    Lamy, M
    ANESTHESIOLOGY, 2000, 93 (3A) : U212 - U212
  • [9] Walking epidural ropivacaine analgesia during labor
    Vallejo, M
    Mandell, G
    Makishima, S
    Ramanathan, S
    ANESTHESIOLOGY, 1999,
  • [10] The dose-sparing effect of clonidine added to ropivacaine for labor epidural analgesia
    Landau, R
    Schiffer, E
    Morales, M
    Savoldelli, G
    Kern, C
    ANESTHESIA AND ANALGESIA, 2002, 95 (03): : 728 - 734