Rapid flow injection electrochemical detection of 3,3′,4,4′ tetrachlorobiphenyl using stabilized lipid membranes with incorporated sheep antibody

被引:3
|
作者
Nikolelis, Dimitrios P. [1 ]
Psaroudakis, Nikolas [3 ]
Michaloliakos, Antonis I. [1 ]
Nikoleli, Georgia-Paraskevi [2 ]
Scoullos, Michael [1 ]
机构
[1] Univ Athens, Dept Chem, Environm Chem Lab, GR-15771 Athens, Greece
[2] Natl Tech Univ Athens, Lab Inorgan & Analyt Chem, Sch Chem Engn, Dept 1, GR-15780 Athens, Greece
[3] Univ Athens, Dept Chem, Lab Inorgan Chem, GR-15771 Athens, Greece
来源
CENTRAL EUROPEAN JOURNAL OF CHEMISTRY | 2013年 / 11卷 / 02期
关键词
Congener; 77; Stabilized lipid films; Biosensor; Flow injection; Antibody regeneration; MICROWAVE-ASSISTED EXTRACTION; POLYCHLORINATED-BIPHENYLS; PCBS;
D O I
10.2478/s11532-012-0157-4
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
An electrochemical biosensor based on a supported polymerized lipid film with incorporated sheep anti-3,3',4,4' tetrachlorobiphenyl (PCB congener 77) antibody using flow injection analysis was developed. The polymerized lipid film contained 85% (w/w) dipalmitoylphosphatidylcholine (DPPC) and 15% (w/w) dipalmitoylphosphatidic acid (DPPA), methacrylic acid, ethylene glycol dimethacrylate, AIBN and sheep anti-congener 77 antiserum. Congener 77 was injected into flowing carrier electrolyte and the flow stopped to detect the antigen. These membranes gave only a single transient proportional to log [congener 77] from 10(-8) to 10(-5) M, with a detection limit of ca. 10(-8) M. A membrane containing 35% (w/w) DPPA was used to examine regeneration. The maximum number of cycles was about 5.
引用
收藏
页码:320 / 323
页数:4
相关论文
共 50 条
  • [1] Rapid Flow Injection Electrochemical Detection of Arochlor 1242 Using Stabilized Lipid Membranes with Incorporated Sheep anti-PCB Antibody
    Michaloliakos, Antonis I.
    Nikoleli, Georgia-Paraskevi
    Siontorou, Christina G.
    Nikolelis, Dimitrios P.
    ELECTROANALYSIS, 2012, 24 (03) : 495 - 501
  • [2] Portable electrochemical aptasensor for highly sensitive detection of 3,3′,4,4′-tetrachlorobiphenyl
    Chen, Beibei
    Wang, Dou
    Wei, Shusheng
    Wang, Juan
    BIOSENSORS & BIOELECTRONICS, 2024, 260
  • [3] A microfluidic ratiometric electrochemical aptasensor for highly sensitive and selective detection of 3,3′,4,4′-tetrachlorobiphenyl
    Ji, Zhiheng
    Wang, Dou
    Wang, Juan
    ANALYTICAL METHODS, 2024, 16 (25) : 4160 - 4167
  • [4] Reproductive Toxicology of 3,3′,4,4′-Tetrachlorobiphenyl in Mice
    J. Rodriguez
    S. D. Kholkute
    W. R. Dukelow
    Bulletin of Environmental Contamination and Toxicology, 1997, 58 : 999 - 1005
  • [5] Design of a simple and novel photoelectrochemical aptasensor for detection of 3,3′,4,4′-tetrachlorobiphenyl
    Fan, Lifang
    Zhang, Caiyun
    Shi, Huijie
    Zhao, Guohua
    BIOSENSORS & BIOELECTRONICS, 2019, 124 : 8 - 14
  • [6] TOXICOKINETICS OF 2,2',4,4'-TETRACHLOROBIPHENYL AND 3,3',4,4'-TETRACHLOROBIPHENYL CONGENERS IN THE HOUSE CRICKET
    LI, MH
    MCKEE, MJ
    ECOTOXICOLOGY AND ENVIRONMENTAL SAFETY, 1992, 24 (03) : 309 - 318
  • [7] Biodegradation of 3,3′,4,4′- tetrachlorobiphenyl by Sinorhizobium meliloti NM
    Wang, Xiaomi
    Teng, Ying
    Luo, Yongming
    Dick, Richard P.
    BIORESOURCE TECHNOLOGY, 2016, 201 : 261 - 268
  • [8] 3,3',4,4'-TETRACHLOROBIPHENYL IN HUMAN FAT AND MILK SAMPLES
    BECK, H
    DROSS, A
    MATHAR, W
    CHEMOSPHERE, 1989, 19 (12) : 1805 - 1810
  • [9] EFFECTS OF 3,3',4,4'-TETRACHLOROBIPHENYL IN THE BRAIN OF THE NEONATAL MOUSE
    ERIKSSON, P
    TOXICOLOGY, 1988, 49 (01) : 43 - 48
  • [10] INFLUENCE OF SYMMETRICAL POLYCHLORINATED BIPHENYL ISOMERS ON EMBRYO AND FETAL DEVELOPMENT IN MICE .2. COMPARISON OF 4,4'-DICHLOROBIPHENYL, 3,3',4,4'-TETRACHLOROBIPHENYL, 3,3',5,5'-TETRACHLOROBIPHENYL, AND 3,3',4,4'-TETRAMETHYLBIPHENYL
    MARKS, TA
    KIMMEL, GL
    STAPLES, RE
    FUNDAMENTAL AND APPLIED TOXICOLOGY, 1989, 13 (04): : 681 - 693