Right ventricular function and dimension before and after endurance running: comparison of full volume 3D echocardiography and cardiovascular magnetic resonance imaging

被引:0
|
作者
Schattke, S. [1 ]
Haettasch, R. [1 ]
Wagner, M. [1 ]
Durmus, T. [1 ]
Borges, A. C. [1 ]
Baumann, G. [1 ]
Schroeckh, S. [1 ]
Sanad, W. [1 ]
Schimke, I. [1 ]
Knebel, F. [1 ]
机构
[1] Charite, D-13353 Berlin, Germany
关键词
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
引用
收藏
页码:1023 / 1023
页数:1
相关论文
共 50 条
  • [1] Single beat 3D echocardiography for the assessment of right ventricular dimension and function after endurance exercise: Intraindividual comparison with magnetic resonance imaging
    Sebastian Schattke
    Moritz Wagner
    Robert Hättasch
    Sabrina Schroeckh
    Tahir Durmus
    Ingolf Schimke
    Wasiem Sanad
    Sebastian Spethmann
    Jürgen Scharhag
    Alexander Huppertz
    Gert Baumann
    Adrian C Borges
    Fabian Knebel
    [J]. Cardiovascular Ultrasound, 10
  • [2] Single beat 3D echocardiography for the assessment of right ventricular dimension and function after endurance exercise: Intraindividual comparison with magnetic resonance imaging
    Schattke, Sebastian
    Wagner, Moritz
    Haettasch, Robert
    Schroeckh, Sabrina
    Durmus, Tahir
    Schimke, Ingolf
    Sanad, Wasiem
    Spethmann, Sebastian
    Scharhag, Juergen
    Huppertz, Alexander
    Baumann, Gert
    Borges, Adrian C.
    Knebel, Fabian
    [J]. CARDIOVASCULAR ULTRASOUND, 2012, 10
  • [3] Can 3D echocardiography challenge magnetic resonance imaging in the assessment of right ventricular size and function?
    Aubert, R.
    Venner, C.
    Haine, D.
    Huttin, O.
    Mercy, M.
    Metzdorf, P. A.
    Maigrat, C. H.
    Chabot, F.
    Juilliere, Y.
    Selton-Suty, C.
    [J]. EUROPEAN HEART JOURNAL, 2016, 37 : 60 - 61
  • [4] Optimal assessment of right ventricular size and function by real-time 3D echocardiography: Comparison to cardiac magnetic resonance Imaging
    Hafeez, N
    Gopal, AS
    Krishnaswamy, R
    Joseph, S
    Toole, RS
    Schapiro, W
    Reichek, N
    [J]. CIRCULATION, 2004, 110 (17) : 570 - 571
  • [5] Assessment of Right Ventricular Function by Real-Time 3D Echocardiography Closely Agrees With Magnetic Resonance Imaging
    Leibundgul, Gregor
    Kessel, Arnheid
    Bernheim, Alain
    Zellweger, Michael
    Buser, Peter
    Handke, Michael
    [J]. CIRCULATION, 2008, 118 (18) : S1001 - S1001
  • [6] Impact of right ventricular volume and function evaluated using cardiovascular magnetic resonance imaging on outcomes after surgical ventricular reconstruction
    Yamazaki, Sachiko
    Numata, Satoshi
    Inoue, Tomoya
    Itatani, Keiichi
    Morimoto, Kazuki
    Ohira, Suguru
    Manabe, Kaichiro
    Yokota, Isao
    Yaku, Hitoshi
    [J]. EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2018, 54 (05) : 867 - 874
  • [7] Comparison of transthoracic three dimensional echocardiography with magnetic resonance imaging in the assessment of right ventricular volume and mass
    Vogel, M
    Gutberlet, M
    Dittrich, S
    Hosten, N
    Lange, PE
    [J]. HEART, 1997, 78 (02) : 127 - 130
  • [8] Accuracy of right ventricular volume and function assessed with cardiovascular magnetic resonance: comparison with echocardiographic parameters
    Couto, Miguel
    Souto, Miguel
    Martinez, Amparo
    Maceira, Alicia
    Vieira, Cecilia
    Pumar, Jose M.
    Croisille, Pierre
    [J]. CLINICAL IMAGING, 2020, 59 (01) : 61 - 67
  • [9] Semi-quantitative assessment of right ventricular function in comparison to a 3D volumetric approach: A cardiovascular magnetic resonance study
    Robin Nijveldt
    Tjeerd Germans
    Gerald P. McCann
    Aernout M. Beek
    Albert C. van Rossum
    [J]. European Radiology, 2008, 18 : 2399 - 2405
  • [10] Semi-quantitative assessment of right ventricular function in comparison to a 3D volumetric approach: A cardiovascular magnetic resonance study
    Nijveldt, Robin
    Germans, Tjeerd
    McCann, Gerald P.
    Beek, Aernout M.
    van Rossum, Albert C.
    [J]. EUROPEAN RADIOLOGY, 2008, 18 (11) : 2399 - 2405