Comparison study of sensitivity factors of elements in glow discharge- & inductively coupled plasma-mass spectrometry

被引:0
|
作者
Kim, YS [1 ]
Plotnikov, M
Hoffmann, V
机构
[1] Korea Univ, Dept Adv Mat Chem, Jochiwon 339700, South Korea
[2] Leibnitz Inst Solid State & Mat Res, D-10169 Dresden, Germany
关键词
glow discharge mass spectrometry; laser ablation ICP-MS; sensitivity factor;
D O I
暂无
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Sensitivity factors of elements by a glow discharge mass spectrometry (GD-MS) were intensively investigated and compared with a laser ablation inductively coupled plasma-mass spectrometry (ICP-MS). In case of copper matrix, the sensitivity factor by GD-MS generally decreases with the increase of the mass number of element. The details are a little different between each data measured by Faraday and multiplier detectors. The factor by a multiplier detector drastically decreases with the mass increase in the region of low mass as in Faraday detector's case, but slowly in the high mass region. On the contrast, the sensitivity factor of solution standard by a conventional ICP-MS slowly increases with the increase of elemental mass number even though there are some exceptions such as gold and also the sensitivity factor by a laser ablation ICP-MS generally increases with mass number of element in the specimen of glass type. In case of steel matrix, any definite trends could not be shown in the relationship between the GD-MS's sensitivity factor and elemental mass.
引用
收藏
页码:1991 / 1995
页数:5
相关论文
共 50 条
  • [1] Inductively Coupled Plasma-Mass Spectrometry
    Esaka, Fumitaka
    ANALYTICAL SCIENCES, 2017, 33 (10) : 1097 - +
  • [2] INDUCTIVELY COUPLED PLASMA-MASS SPECTROMETRY
    OLIVARES, JA
    METHODS IN ENZYMOLOGY, 1988, 158 : 205 - 222
  • [3] Inductively Coupled Plasma-Mass Spectrometry
    Fumitaka Esaka
    Analytical Sciences, 2017, 33 : 1097 - 1098
  • [4] INDUCTIVELY COUPLED PLASMA-MASS SPECTROMETRY
    DATE, AR
    SPECTROCHIMICA ACTA REVIEWS, 1991, 14 (1-2): : 3 - 32
  • [5] Multianalysis of trace elements in mosses with inductively coupled plasma-mass spectrometry
    Ayrault, S
    Bonhomme, P
    Carrot, F
    Amblard, G
    Sciarretta, MD
    Galsomiès, L
    BIOLOGICAL TRACE ELEMENT RESEARCH, 2001, 79 (02) : 177 - 184
  • [6] Multianalysis of trace elements in mosses with inductively coupled plasma-mass spectrometry
    S. Ayrault
    P. Bonhomme
    F. Carrot
    G. Amblard
    M. D. Sciarretta
    L. Galsomiès
    Biological Trace Element Research, 2001, 79 : 177 - 184
  • [7] A STUDY OF INTERNAL STANDARDIZATION IN INDUCTIVELY COUPLED PLASMA-MASS SPECTROMETRY
    THOMPSON, JJ
    HOUK, RS
    APPLIED SPECTROSCOPY, 1987, 41 (05) : 801 - 806
  • [8] Determination of 10 Elements in Breast Milk by Inductively Coupled Plasma-Mass Spectrometry
    Wang Y.
    Zhao J.
    Qiao W.
    Zhang M.
    Liu Y.
    Chen L.
    Shipin Kexue/Food Science, 2021, 42 (14): : 165 - 169
  • [9] INDUCTIVELY COUPLED PLASMA-MASS SPECTROMETRY OF SYNTHETIC ELEMENTS - TC-99
    CRAIN, JS
    GALLIMORE, DL
    APPLIED SPECTROSCOPY, 1992, 46 (03) : 547 - 549
  • [10] Determination of 27 Elements in Animal Feed by Inductively Coupled Plasma-Mass Spectrometry
    King, Thomas
    Sheridan, Robert
    JOURNAL OF AOAC INTERNATIONAL, 2019, 102 (02) : 434 - 444