Comparison of the Humphrey Field Analyser and Humphrey Matrix Perimeter for the Evaluation of Glaucoma Patients

被引:3
|
作者
Chen, Yi-Hao [1 ]
Wu, Jian-Nan [1 ]
Chen, Jiann-Torng [1 ]
Lu, Da-Wen [1 ]
机构
[1] Tri Serv Gen Hosp, Natl Def Med Ctr, Dept Ophthalmol, Taipei 114, Taiwan
关键词
Visual field; Glaucoma; Humphrey Matrix Perimeter; Humphrey Field Analyser;
D O I
10.1159/000154203
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Aims: To compare the Humphrey Matrix Perimeter (HMP) with the Humphrey Field Analyser (HFA) in visual-field examinations of patients with glaucoma or suspected glaucoma. Methods: One hundred and forty-nine patients with suspected glaucoma or glaucoma were recruited. All patients underwent visual-field examinations with the Swedish Interactive Threshold Algorithm standard, the central 30-2 threshold test with the HFA, and the frequency doubling technique 30-2 threshold test with the HMP. The examination times, mean deviations (MDs) and pattern standard deviations (PSDs) of both perimeters were compared in all patients and according to the patient's diagnosis or the severity of their visual-field defects (VFDs). The paired 2-tailed t test and Pearson's correlation coefficients were used for statistical analyses. Results: Overall, the examination times were significantly shorter with the HMP than with the HFA. There was a positive correlation between the HFA and HMP measurements of MD and PSD. In patients with suspected glaucoma, the PSDs measured with the HMP were significantly higher than those measured with the HFA. In patients with mild VFDs (MD >-4.0 dB), PSDs measured with the HMP were significantly higher than those measured with the HFA. In patients with severe VFDs (MD <-12.0 dB), MDs measured with the HMP were significantly higher than those measured with the HFA, whereas PSDs measured with the HMP were significantly lower than those measured with the HFA. Conclusions: The HMP is more time efficient than the HFA in visual-field examinations. The HMP tends to overestimate mild VFDs and underestimate severe VFDs. Copyright (C) 2008 S. Karger AG, Basel
引用
收藏
页码:400 / 407
页数:8
相关论文
共 50 条
  • [1] Comparison of visual field sensitivities between the Medmont automated perimeter and the Humphrey field analyser
    Landers, John
    Sharma, Alok
    Goldberg, Ivan
    Graham, Stuart L.
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2010, 38 (03): : 273 - 276
  • [2] A Comparison of Perimetric Results from a Tablet Perimeter and Humphrey Field Analyzer in Glaucoma Patients
    Kong, Yu Xiang George
    He, Mingguang
    Crowston, Jonathan G.
    Vingrys, Algis J.
    TRANSLATIONAL VISION SCIENCE & TECHNOLOGY, 2016, 5 (06):
  • [3] A comparison of visual field testing with a new automated perimeter, the Compass visual field analyser, and the Humphrey visual field analyser
    Fenolland, J. R.
    Bonnel, S.
    Rosenberg, R.
    Sendon, D.
    Ghazal, W.
    Giraud, J. M.
    Renard, J. P.
    ACTA OPHTHALMOLOGICA, 2016, 94
  • [4] Comparison between indices of humphrey matrix and humphrey perimetry in early glaucoma patients and normal subjects
    Hong, Samin
    Yeom, Ho Yeop
    Kim, Chan Yun
    Seong, Gong Je
    ANNALS OF OPHTHALMOLOGY, 2007, 39 (04) : 318 - 320
  • [5] Comparison of the TEMPO binocular perimeter and Humphrey field analyzer
    Takashi Nishida
    Robert N. Weinreb
    Juan Arias
    Cristiana Vasile
    Sasan Moghimi
    Scientific Reports, 13
  • [6] Comparison of a portable perimeter with the Humphrey Field Analyzer in Telemedicine
    Antwi-Adjei, Ellen
    Swain, Thomas
    Racette, Lyne
    Rhodes, Lindsay
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2023, 64 (08)
  • [7] Home-based visual field test for glaucoma screening comparison with Humphrey perimeter
    Tsapakis, Stylianos
    Papaconstantinou, Dimitrios
    Diagourtas, Andreas
    Kandarakis, Stylianos
    Droutsas, Konstantinos
    Andreanos, Konstantinos
    Brouzas, Dimitrios
    CLINICAL OPHTHALMOLOGY, 2018, 12 : 2597 - 2606
  • [8] Comparison of the TEMPO binocular perimeter and Humphrey field analyzer
    Nishida, Takashi
    Weinreb, Robert N.
    Arias, Juan
    Vasile, Cristiana
    Moghimi, Sasan
    SCIENTIFIC REPORTS, 2023, 13 (01)
  • [9] Effects of astigmatism on the Humphrey Matrix perimeter
    Yoshii, Toshiaki
    Matsuura, Toyoaki
    Yukawa, Eiichi
    Hara, Yoshiaki
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2009, 19 (03) : 425 - 428
  • [10] MULTICENTER LONGITUDINAL COMPARISON OF PERIMETRY RESULTS BETWEEN IPAD PERIMETER AND HUMPHREY FIELD ANALYZER FOR GLAUCOMA
    Kong, Yu Xiang George
    Prea, Selwyn Marc
    Mehta, Aditi
    He, Mingguang
    Crowston, Jonathan
    Gupta, Viney
    Martin, Keith
    Vingrys, Algis
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2017, 45 : 23 - 23