A simple and accurate method for calibrating the oscillation amplitude of tuning-fork based AFM sensors

被引:22
|
作者
Liu, Jinquan [1 ]
Callegari, Andrea [1 ]
Stark, Martin [1 ]
Chergui, Majed [1 ]
机构
[1] Ecole Polytech Fed Lausanne, Lab Spectroscopie Ultrarapide, CH-1015 Lausanne, Switzerland
关键词
SNOM; NSOM; AFM; Tuning fork; Interferometry;
D O I
10.1016/j.ultramic.2008.08.009
中图分类号
TH742 [显微镜];
学科分类号
摘要
We have developed a simple and accurate method for calibrating the amplitude of vibration of quartz tuning fork sensors commonly used in atomic force- and near field optical-microscopy. Unlike interferometric methods, which require a complex optical setup, the method we present requires only a simple measurement of the electro-mechanical properties of the tuning-fork oscillator and can be performed in a matter of minutes without disturbing the experimental setup. Comparison with interferometric methods shows that an accuracy of better than few percent can be routinely achieved. (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:81 / 84
页数:4
相关论文
共 50 条
  • [1] A SIMPLE AND RELIABLE TUNING-FORK TEST FOR RECRUITMENT
    CHANDLER, JR
    ARCHIVES OF OTOLARYNGOLOGY, 1958, 67 (01): : 67 - 68
  • [2] Nanolithography on silicon surface using a tuning-fork STM/AFM
    Lin, HY
    Fan, CC
    Tsai, DP
    Chien, FSS
    Gwo, S
    Hsieh, WF
    OPTICAL ENGINEERING FOR SENSING AND NANOTECHNOLOGY (ICOSN 2001), 2001, 4416 : 354 - 359
  • [3] Fabrication of a quartz tuning-fork probe with a sharp tip for AFM systems
    Hida, H.
    Shikida, M.
    Fukuzawa, K.
    Murakami, S.
    Sato, Ke.
    Asaumi, K.
    Iriye, Y.
    Sato, Ka.
    SENSORS AND ACTUATORS A-PHYSICAL, 2008, 148 (01) : 311 - 318
  • [4] Calibration of the oscillation amplitude of quartz tuning fork-based force sensors with astigmatic displacement microscopy
    Zhang, Bi-Qin
    Ma, Fei-Cen
    Xu, Jia-Nan
    Ren, Dou-Dou
    Zhou, Dan
    Pan, Ting
    Zhou, Lei
    Pu, Qiaosheng
    Zeng, Zhi-Cong
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2024, 95 (01):
  • [5] Temperature sensor based on quartz tuning-fork resonator
    Xu, J
    Ai, H
    Li, X
    Li, QL
    2004: 7TH INTERNATIONAL CONFERENCE ON SOLID-STATE AND INTEGRATED CIRCUITS TECHNOLOGY, VOLS 1- 3, PROCEEDINGS, 2004, : 1727 - 1730
  • [6] Quartz tuning-fork type AFM probe operated in anti-phase vibration mode
    Hida, H.
    Shikida, M.
    Fukuzawa, K.
    Ono, A.
    Sato, K.
    Asaumi, K.
    Iriye, Y.
    Sato, K.
    2006 IEEE INTERNATIONAL SYMPOSIUM ON MICRO-NANOMECHATRONICS AND HUMAN SCIENCE, 2006, : 355 - +
  • [7] A precision method of calibrating a tuning fork by comparison with a pendulum
    Moon, C
    BUREAU OF STANDARDS JOURNAL OF RESEARCH, 1930, 4 (1-3): : 213 - 219
  • [8] Performance Characteristics and Temperature Compensation Method of Fluid Property Sensor Based on Tuning-Fork Technology
    Chen, Yuan
    Mei, Guifu
    Yang, Huanhuan
    Yu, Fei
    Gao, Jun
    JOURNAL OF SENSORS, 2016, 2016
  • [9] Data-analysis method for hydrogen embrittlement tuning-fork test
    Pohjonen, Aarne
    Latypova, Renata
    Seppaelae, Oskari
    MATERIALS AND CORROSION-WERKSTOFFE UND KORROSION, 2023, 74 (10): : 1514 - 1520
  • [10] A simple and accurate method of calibrating chronoscopes
    Dorcus, RM
    Mount, GE
    AMERICAN JOURNAL OF PSYCHOLOGY, 1941, 53 : 442 - 444