Ultrasound quality assurance phantoms and characterization for high frequency transducers

被引:1
|
作者
Gottlieb, EJ [1 ]
Chen, WH [1 ]
Ritter, TA [1 ]
Shung, KK [1 ]
机构
[1] Penn State Univ, University Pk, PA 16802 USA
关键词
ultrasound; phantoms; quality assurance; transducer characterization; high frequency;
D O I
10.1117/12.462180
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Ultrasound phantoms are used as a quality assurance mechanism for assessing the imaging performance of ultrasound transducers. Several phantoms have been fabricated specifically for imaging by means of high frequency transducers with a center frequency ranging from 20 to 100 MHz. To quantify the transducers' imaging performance the spatial resolution, dead zone, linear fidelity, depth of penetration and image uniformity are measured from ultrasound images created by scanning specially designed phantoms. Eight micron diameter tungsten (high acoustic reflectivity and diameter size less than lambda/2) wire targets are used for all the phantoms. Transducer characterization consists of a standard pulse echo analysis and insertion loss measurement for each transducer. Imaging of quality assurance phantoms and transducer characterization provide a practical means for evaluating the performance of high frequency transducers.
引用
收藏
页码:406 / 411
页数:6
相关论文
共 50 条
  • [1] Evaluation of two quantitative ultrasound phantoms for use in daily quality assurance
    Gumy, C
    Alekxandrova, I
    Perron, C
    Slosman, DO
    Hans, D
    OSTEOPOROSIS INTERNATIONAL, 2000, 11 : 14 - 14
  • [2] Evaluation of quantitative ultrasound phantoms for use in daily quality assurance.
    Fan, B
    Chen, MB
    Njeh, CF
    He, Y
    Diessel, E
    Wu, C
    Hans, D
    Fuerst, T
    Genant, HK
    JOURNAL OF BONE AND MINERAL RESEARCH, 1999, 14 : S501 - S501
  • [3] Passive materials for high frequency ultrasound transducers
    Wang, HF
    Ritter, T
    Cao, WW
    Shung, KK
    MEDICAL IMAGING 1999: ULTRASONIC TRANSDUCER ENGINEERING, 1999, 3664 : 35 - 42
  • [4] Thermal Characterization of Phantoms Used for Quality Assurance of Deep Hyperthermia Systems
    Farina, Laura
    Sumser, Kemal
    van Rhoon, Gerard
    Curto, Sergio
    SENSORS, 2020, 20 (16) : 1 - 9
  • [5] ROUTINE QUALITY ASSURANCE OF HIGH-FREQUENCY ULTRASOUND BREAST SCANNERS IN A SCREENING CONTEXT
    EVANS, JA
    MOORE, RD
    METCALFE, SC
    DAVIS, M
    BRITISH JOURNAL OF RADIOLOGY, 1993, 66 (787): : 614 - 618
  • [6] Nanocomposite Matching Layers for High Frequency Ultrasound Transducers
    Zhou, Q. F.
    Cha, J. H.
    Huang, Y.
    Zhang, R.
    Cao, W.
    Shung, K. K.
    2006 IEEE ULTRASONICS SYMPOSIUM, VOLS 1-5, PROCEEDINGS, 2006, : 2365 - +
  • [7] Development of High Frequency Ultrasound Transducers for Medical Imaging
    Cannata, J.
    Zhou, Q.
    Williams, J.
    Hu, C. H.
    Shung, K.
    MEDICAL PHYSICS, 2009, 36 (06)
  • [8] MODELING AND OPTIMIZATION OF HIGH-FREQUENCY ULTRASOUND TRANSDUCERS
    LOCKWOOD, GR
    FOSTER, FS
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1994, 41 (02) : 225 - 230
  • [9] New phantoms for quality assurance in cardiac CT
    Ulzheimer, S
    Kachelriess, M
    Kalender, WA
    RADIOLOGY, 1999, 213P : 402 - 402
  • [10] Anthropomorphic phantoms for quality assurance in radiation therapy
    Alvarez, P
    Molineu, A
    Hernandez, N
    Followill, D
    Balter, P
    Hanson, W
    Ibbott, G
    MEDICAL PHYSICS, 2004, 31 (06) : 1732 - 1732